Specifications
SKU: CUSTOM Fully automatic flexible clamp meter CFL-02R
Product overview
It is now more affordable than the previous model (CFL-01U) *2 !
- The cable can be freely shaped, making it easy to measure even in tight spaces.
- The true RMS method allows the display of RMS values for waveforms other than sine waves.
- Current and frequency can be displayed simultaneously on the LCD screen.
- Adopts a hand grip style that allows for a firm grip.
- The LCD screen is equipped with a backlight to make it easier to check values even when measuring in a dark place.
- Equipped with an LED light that brightly illuminates the object to be measured, making it easier to work in dark places.
- The data hold function allows you to check the measured values at your leisure.
Usage example
AC current measurement image
After removing the clamp sensor coil at the joint, clamp the object to be measured.
LED light function brightly illuminates the object being measured
Equipped with a backlight LCD for easy viewing even in dark placesPart names
Main unit
- ①Clamp sensor coil
- ②LED light
- ③Clamp sensor connection part
- ④Display section
- ⑤Backlight button
- ⑥ LED light button
- ⑦Hold button
- 8. Power button
display
- ① Battery level display
- ②Auto mode display
- ③Data hold display
- ④DC voltage mode
- ⑤AC voltage mode
- ⑥ Main display
- ⑦Unit display
- ⑧ Sub display
- ⑨Auto power off function enabled indicator
360° rotating image
Clicking on the image will open a new window.
specification
Electrical Performance
Flexible clamp part
| range | resolution | Accuracy | frequency | |
|---|---|---|---|---|
| ACA | 0.2 to 10 A | 0.01 A | ±(2.0% rdg + 10 dgt) | 40 to 65 Hz |
| 10 to 60 A | 0.01 A | ±(1.5% rdg + 5 dgt) | ||
| 60 to 600 A | 0.1 A | |||
| 600 to 3000 A | 1 A | ±(2.0% rdg + 5 dgt) | ||
| 0.2 to 60 A | 0.01 A | ±(2.5% rdg + 5 dgt) | 65 to 200 Hz | |
| 60 to 600 A | 0.1 A | |||
| 600 to 3000 A | 1 A | ±(3.0% rdg + 5 dgt) | ||
| 0.2 to 60 A | 0.01 A | ±(3.0% rdg + 5 dgt) | 200 Hz to 1 kHz | |
| 60 to 600 A | 0.1 A | |||
| 600 to 1000 A | 1 A | |||
| frequency | 40 to 1000 Hz | 0.1 Hz | ±(0.5 % rdg + 2 dgt) at 3 A or more | - |
*Accuracy is the value measured at the center of the clamp sensor coil. Accuracy guaranteed range: AC60A range: 0.2 to 60 A, AC600A range: 60 to 600 A, AC3000A range: 600 to 3000 A
Error due to conductor position
Accuracy is specified at the center of the clamp sensor coil. Add the following value to the accuracy depending on the distance from the center of the clamp sensor coil to the center of the conductor not being measured.| Distance from center | Addition to accuracy | |
|---|---|---|
| A | Radius 35 mm (Φ70) | ±0.5% |
| B | Radius 50 mm (Φ100) | ±1.5% |
| C | Radius 60 mm (Φ120) | ±2.0% |
| D | Radius 60 mm (Φ120) or more | ±5.0% |
General specifications
| Detection method | True RMS |
|---|---|
| display | LCD display, 6000 counts |
| Range switching | Auto |
| Maximum measurement conductor diameter | φ120 mm |
| sampling | Approximately 3 times/second |
| Auto Power Off | Approximately 5 minutes (cannot be canceled) |
| Operating temperature and humidity | 0 to +40°C, 80% RH or less (no condensation) |
| Storage temperature and humidity | -10 to +60°C, 80% RH or less (excluding batteries, no condensation) |
| size | Approx. W 178 × H 324 × D 30 mm |
| weight | Approximately 188 g (including batteries) |
| power supply | 3 x AAA batteries |
| battery life | Up to approximately 70 hours (when using alkaline batteries) *3 |
| accessories | Storage case, instruction manual |
| proofreading | Possible |
| Compliance standards | EN61010-1, EN61010-2-032, EN61326-1 CAT III 1000V, CATIV 600V |