Specifications
SKU: CUSTOM Analog Earth Resistance Meter ET-01U
Product overview
Supports measurement of ground resistance and ground voltage.
- Supports both the "three-wire" type for precision measurement and the "two-wire" type for simple measurement.
- The ground voltage measurement function can measure up to a maximum voltage of AC30V.
- Comes with an LED that allows you to check the correct grounding status.
- Comes with a backlight that allows measurements even in dark places.
- For power distribution lines, indoor wiring, electrical machinery equipment, and grounding copper rod construction sites.
How to use
Precision Measurement
Simple measurement
. *Please wear protective insulating equipment when measuring or in areas where electric shock is expected around the object being measured.
Part names
Main unit
- ①Scale plate
- ②Meter pointer
- ③AUX.SPIKE OK lamp
- ④MEAS measurement switch (with LOCK function)
- ⑤Measurement terminal
- ⑥ Pointer zero adjuster
- ⑦Light switch
- ⑧Range switch
- ⑨Battery cover
- 10. Stand
- ⑪T-type auxiliary grounding rod
- ⑫Precision measurement probe set
- 13. Safety alligator clips (1 each red and black)
- 14. Flat test rods (1 each red and black)
- ⑮ Simple ground probe set
specification
Electrical Performance
| Measurement Range | Measurement range | resolution | Accuracy | |
|---|---|---|---|---|
| Ground voltage | - | 0 to 30 V AC (50/60 Hz) | 0.5 V | ±3.0% of full scale value |
| earth resistance | × 100 | 0 to 1200 ohms | 20 ohms | ±3.0% of maximum scale value (auxiliary earth resistance is 100 Ω ±5%) (earth voltage is 10 V or less) |
| × 10 | 0 to 120 ohms | 2 ohms | ||
| × 1 | 0 to 12 ohms | 0.2 Ω |
| Maximum measurement current output | 3mA | |
|---|---|---|
| Ground voltage measurement method | Average value rectification | |
| Earth resistance measurement method | AC constant current measurement output |
|
| AC constant current frequency output | Approximately 820Hz | |
| Maximum measurable error range (measurement range in which the maximum operating error (±30%) is maintained) |
|
|
*23 ±5 ℃, 75% RH or less
General specifications
| display | Analog meter tote band type |
|---|---|
| Operating temperature and humidity | 0 to +40°C, 85% RH or less (no condensation) |
| Storage temperature and humidity | -20 to +60°C, 75% RH or less (no condensation) |
| Reaction time | within 1 second |
| Insulation resistance | Between the measurement terminal and the outer case: 100MΩ / DC 1000 V |
| Withstand voltage | Between the measurement terminal and the outer case: AC 3700 V (50/60 Hz) for 1 minute |
| Measurement compatible grounding type |
|
| size | Approx. W 112 × H 160 × D 50 mm |
| weight | Approximately 350 g (excluding batteries) |
| power supply | 4 x AA batteries |
| accessories |
|
| Optional accessories |
|
| proofreading | Possible |
| Compliance standards |
|
| JAN | 4983621110067 |