Specifications

SKU: LINSHANG LS117 Optical Density Mete

LS117 Optical Density Meter

Suitable for testing opalescent translucent materials

Visible light transmittance and optical density can be measured simultaneously
Measuring accurately, and ensure it can pass the inspection of Chinese national authoritative metrology institute
 

LS117 densitometer features and operation

 

LS117 densitometer is an instrument that can measure both optical density and light transmittance. The instrument adopt the diffuse transmission principle which is suitable for the optical density test of opalescent translucent materials and frosted matte materials. The light source of the instrument complies with the CIE photopic luminosity function and can pass the inspection of Chinese national metrological institute.

Application

Suitable for testing optical density of aluminized film, film, X-ray film, lens ink and other materials. The optical density meter is suitable for testing the light transmittance of opalescent translucent materials, matte materials.

 
 
 

 
 
 
 

Parameters

Parameter Value
Light Transmittance Measurement Accuracy ±1% (0%-50%)
±2% (50%-100%)
Light Transmittance Resolution 0.0005% (0%-10%)
0.005% (10% -100%)
Optical Density Measurement Range 0.000OD-6.000OD
Optical Density Measurement Accuracy ±0.02 (0-2.00OD)
±1% (2.00-4.00OD)
±2% (4.00-6.00OD)
Optical Density Resolution 0.001 OD (0.00-2.00OD)
0.01 OD (2.00-4.00OD)
0.1 OD (4.00-6.00OD)
Aperture 2mm
Light Source 380nm-760nm, conforming to CIE photopic luminosity function
Weight About 576g (without battery)
Power Supply 4*AAA alkaline dry battery
Display 240*160 dot-matrixes LCD
Dimension 148mm×76mm×26mm (L*W*H)
 

Features

High resolution, wide optical density measurement range

The optical density meter has wide measuring range. The optical density value can be measured to OD 6. The transmittance resolution is up to 0.005%

 

Light transmittance and optical density are measured simultaneously

During the test, the interface displays both the transmittance value and the optical density value of the material

 


Diffuse transmission light path design

The LS117 portable densitometer uses a diffuse transmission light path design, which has the same effect of the integrating sphere. There are relevant instructions in "GB / T 11500-2008 / ISO 5-2: 2001". The regulation has stated that “Use opale glass method instead of integrating sphere method as the basis of ISO standard diffuse transmission density"

 