LINSHANG LS153 Vacuum Coating Thickness Measuring System

Specifications

SKU: LINSHANG LS153 Vacuum Coating Thickness Measuring System

LS153 Vacuum Coating Thickness Measuring System

Online thickness measurement equipment for concentration coating machine, online monitoring of material uniformity

Independent digital probe design, easy to operate and install
Two-way RS485/MODBUS, can be connected to PLC, HMI and PC
High measurement accuracy and good stability of test data
Free to choose the size and number of test points, 45 test points can be customized at most

 

The vacuum coating thickness measuring system works in the principle that the transmittance (optical density) of the material at a specific wavelength of light is proportional to the coating thickness. The uniformity of the material is achieved by monitoring the optical transmittance (optical density) of the material. The thicker the coating, the higher the optical density and the lower the transmittance. As long as the light can pass through the material, the product quality can be controlled by monitoring the transmittance (optical density).

The device is able to measure the thickness of the coating layer of the product online in real time, which helps to grasp and monitor the quality of the product in the production process, find out the problems and adjust the process as early as possible, so as to improve the quality of the product and reduce the rate of scrap. This vacuum coating thickness measuring system is widely used in concentration vacuum coating machine, glass coating, glass production line, coating production line and other fields.
 

LS153 Vacuum Coating Thickness Measuring System Introduction

Size and number of monitoring points can be customised

The user can freely choose the number of test points, up to 45 test points can be customised. The actual length of the device is based on the number of customized test points.

 


Exterior view of LS153, 9 test points, with HMI and alarm light

RS485 communication interface/MODBUS communication protocol

The instrument provides dual RS485 communication interface and standard MODBUS communication protocol, which is convenient for communication with PLC, Single Chip Microcomputer, human-machine interface, kingview, computer and so on. The optical density data can be read on the coating machine to realize control automation (closed-loop control).

 


System Composition

The equipment is mainly divided into three parts: measure and control units, human-machine interface, computer real-time monitoring software (optional).

 

Measure and control units

They mainly includes light source probe, receiving probe, controller, aluminum profile frame.

 


Independent digital probe design, easy to operate and install

A set of probes contains a light source probe and a receiver probe, with 4 mounting screw holes on the light hole side and 4 mounting screw holes on the side of the probe for easy installation.

 


Human-machine interface

There are 3 types of HMI control boxes to choose from: recessed, wall-mounted and desktop (detailed drawings will be provided for confirmation at the time of ordering).

 

Computer real-time monitoring system (optional)

Real-time monitoring of the data, including real-time display, histogram, setting of upper and lower limits, real-time curve and alarm when the limit is exceeded. The transmittance and optical density display can be switched freely.

 

 
 
 
 

Control console and installation method

The controller and the test probe are embedded in the control console and only need to fix the control console during installation. Each device is equipped with a bracket, which is customized according to the actual installation needs of customers.

 


Installation diagram of the control console
 
Schematic diagram of minimum dimensions for special customisation Schematic diagram of minimum dimensions for special customisation

Features

1.Ultra-small digital probe, super easy to use and install, only 6 wires to be connected.

2.The instrument use optical non-contact measurement, without direct contact with the test material. It will not cause damage to the tested material.

3.RS485 interface and MODBUS communication protocol, which is convenient for communication with PLC, Single Chip Microcomputer, human-machine interface, kingview, computer and so on, and can achieve closed-loop control by communicating with the coating machine.

4.The vacuum coating thickness measuring system has high measurement accuracy.

5.The instrument use modular design, each module is connected by aviation connector, single point is removable, which is convenient for future maintenance.

6.With dust-proof design, dust does not affect the inside of the gyroscope. Customers just need to clean the front glass of the probe.

7.The instruemtn has over-limit alarm function and can intelligently control production quality. The instrument can reduce dependence on manual operation and improve production efficiency and quality.

8.The instrument has a temperature compensation function, the value is stable, allowing the use of high-temperature environments.

9. The instrument is equipped with automatic calibration and manual calibration function, which can be freely set by the user according to the need.

10.Equipped with human-machine interface, real-time monitoring of the data, including real-time display, histogram, upper and lower threshold settings, over-limit alarm, RS485 ② communication parameter settings, etc. The transmittance and optical density display can be switched freely.

 

System Parameters

Parameters LS153
Test Wavelength (Optional) Green light: 530nm; Infrared: 850nm
Measuring Spot 5mm
Transmittance Measurement Accuracy ±1%
Transmittance Resolution 0.005%
Optical Density Measurement Range 0.00 OD - 6.00 OD
Optical Density Resolution 0.01 OD for 0.00-3.00 OD
0.05 OD for 3.00-5.00 OD
0.15 for 5.00 - 6.00 OD
Maximum Measurement Points 45 points
Distance Between Adjacent Probe Minimum distance of 35mm
Distance Between Receiving Probe and Light Source Probe 20mm
Temperature Range -10°C - 60°C
Storage Temperature -20°C - 70°C
Relative Humidity less than 85%, no condensation
Data Refresh Cycle Normal mode 300ms/ Fast mode 100ms
Communication Interface Dual RS485
Communication Protocol MODBUS protocol
Dimension 80mm(W)*180mm(H)*L (Customized)
Vacuum Flange Electrode Cores 6 ( RS485①+DC7.5V)
9 ( RS485①+ RS485②+DC7.5V)
Power Supply 220V AC/50Hz

 