Constant pressure residual chlorine detection module includes pH electrode, residual chlorine electrode (platinum electrode, titanium electrode), installation backplane, flow meter and controller. The residual chlorine electrode adopts a constant pressure three-electrode system without installing electrode membrane and electrolyte, the unique structure design enable platinum electrode offer residual chlorine good sensitivity in the testing water, even at very low concentration circumstance, the residual chlorine can be measured as well. Moreover, including the design of automatic cleaning,the water flow driven cleaning ball continuously collide and polish the surface of platinum electrode and titanium electrode to reduce physical attachment and chemical oxidation of the electrode surface, the maintenance frequency can be lowered effectively

 
Product Details

Constant Pressure Residual Chlorine Detection Module LH-DL06

Introduction
Constant pressure residual chlorine detection module includes pH electrode, residual chlorine electrode (platinum electrode, titanium electrode), installation backplane, flow meter and controller. The residual chlorine electrode adopts a constant pressure three-electrode system without installing electrode membrane and electrolyte, the unique structure design enable platinum electrode offer residual chlorine good sensitivity in the testing water, even at very low concentration circumstance, the residual chlorine can be measured as well. Moreover, including the design of automatic cleaning,the water flow driven cleaning ball continuously collide and polish the surface of platinum electrode and titanium electrode to reduce physical attachment and chemical oxidation of the electrode surface, the maintenance frequency can be lowered effectively
Specification
Item
Specification
Test Item
Residual chlorine, pH, temperature, flow rate
Measuring
Range
Residual Chlorine:0.00-3.00mg/L
pH:2.00-12.00
Temperature:0-60.0℃
Flow rate:16.0-40.0L/H
Accuracy
Residual Chlorine:0.01~0.20:±0.02mg/L;
0.21~3.00mg/L;±0.10mg/L or 5%,whichever is greater
pH:±0.10
Temperature:±0.5℃
Flow rate:±5%
Resolution
Residual Chlorine:0.01mg/L
Current:0.01μA
pH:0.01
Temperature:0.1℃
Flow rate:1L/H
Temperature element
NTC 10K
Flow rate requirement
16.0~40.0L/H,20.0L/H optimal
Power
0.5W
Power supply
12~24VDC;standard 5m shielded ,length OEM available
Data output
RS-485/MODBUS-RTU protocol
IP grade
BNC and flow meter interface: IP65; Other interfaces and structural parts: IP68
Main material
PMMA/PC/PTFE/glass/titanium/platinum/304 stainless steel/silicone O-ring