ZADETECTOR Portable Gas Detector Alarm G60

Specifications

SKU: ZADETECTOR Portable Gas Detector Alarm G60

Display method LCD
Ambient temperature -25℃ to +55℃
Relative humidity (20~93)% (non-condensing)
Operating voltage DC 3.7 V
Battery capacity 6000 mA lithium-ion rechargeable battery
Charging time <5 h
Operating time ≥8 h (continuous) (at room temperature)
Dimensions L291mm × W100mm × H49mm

The device supports multiple detection modes and configuration combinations, including:

  1. Probe-type gas leak detector (diffusion type)
  2. Probe-type gas leak detector (pump-suction type)
  3. Standard 4-in-1 gas detector (pump-suction type)
  4. Methane detector with triple measurement ranges (pump-suction type)
  5. Laser methane remote detector

Among these, the laser methane remote detector can be flexibly combined with any of the above detection modes.

Functions Features

Henan Zhong An Electronic Detection Technology CO.,LTD.Henan Zhong An Electronic Detection Technology CO.,LTD.Henan Zhong An Electronic Detection Technology CO.,LTD.Henan Zhong An Electronic Detection Technology CO.,LTD.Henan Zhong An Electronic Detection Technology CO.,LTD.

Technical Parameters

Technical parameters of probe leak detector (diffusion type/pump suction type):
Detection Method Probe Leak Detection - Diffusion/Pump Suction
Detection Principle Semiconductor Type
Suitable Gases Combustible Gases
Measurement Range (0~10000) µmol/mol, (0~10000) PPM
Resolution 1 µmol/mol, 1 PPM
Accuracy Class ±3%FS
Alarm Setpoint Adjustable
Response Time T90 ≤30 s
Standard 4-in-1/Methane 3-range (pump-suction type) technical parameters:
Detection Method Methane Three-Range (Pump Suction)
Detection Principle Infrared, Semiconductor
Suitable Gases Combustible Gases
Detected Gas Methane
Measurement Range (0~100)%LEL, (0~100)%VOL, (0~10000)µmol/mol, (0~10000)PPM
Resolution 1%LEL, 0.1%VOL, 1µmol/mol, 1PPM
Accuracy Class ±3%FS
Response Time T90 ≤30 s
Alarm Setpoint 20%LEL for low alarm, 50%LEL for high alarm
Technical parameters of the laser telemetry model:
 
Suitable gases Combustible gases
Detectable gas Methane
Detection range (0~50000) ppm·m
Detection distance (0-15) m, (0-30) m selectable
Lowest detection limit 5 ppm·m
Accuracy ±10%FS
Response time 0.5s
All of them have the following general technical parameters:
 
Display method LCD
Ambient temperature -25℃ to +55℃
Relative humidity (20~93)% (non-condensing)
Operating voltage DC 3.7 V
Battery capacity 6000 mA lithium-ion rechargeable battery
Charging time <5 h
Operating time ≥8 h (continuous) (at room temperature)
Dimensions L291mm × W100mm × H49mm
 