Share:


ZADETECTOR GTYQ-QD6390 Independent gas detector

Specifications

SKU: ZADETECTOR GTYQ-QD6390 Independent gas detector

Detection principle

Electrochemical, catalytic combustion, infrared, semiconductor, heat conduction, PID photoion, etc.

Sampling method

Natural diffusion

Power supply

AC220V

Explosion-proof method

Flameproof type

The QD6390 gas detector can be used in places where flammable and explosive gases leak. It adopts catalytic combustion sensor and its imported electrochemical sensor technology. The product has the advantages of stable signal and high precision. The instrument housing is made of cast aluminum one-shot explosion-proof and flameproof design, suitable for use in various dangerous places.
QD6390AC 220V independent gas detector; high-performance sensor with high measurement accuracy and good repeatability; with relay output, data recovery, data storage and other functions; independent gas chamber structure, modular sensor replacement is easy; It comes with 2 sets of relays inside, which can control fans, sound and light alarms, solenoid valves and other equipment.

Functions Features

 
  • Standalone Gas Detection System
    Independent operation with integrated design, ideal for fixed installation in industrial and commercial environments.
  • Flexible Power & Output Options
    Supports DC24V / AC220V pulse relay output, enabling direct control of external devices such as fans and solenoid valves.
  • Direct Valve Connection
    Can be connected directly to solenoid valves without additional converters, simplifying installation.
  • Wireless Data Transmission (Optional NB-IoT)
    Optional NB module enables real-time wireless data transmission to alarm control panels without on-site wiring.
  • Remote Monitoring
    Supports mobile and PC remote monitoring, allowing users to access gas data anytime, anywhere.
  • Integrated Audible & Visual Alarm
    Built-in sound and light alarm system provides instant alerts for gas leaks.
  • Dual-Level Alarm Setting
    Configurable low and high concentration alarms for enhanced safety protection.
  • Industrial-Grade EMC Protection
    Equipped with advanced EMC module to ensure stable operation in harsh and high-interference environments.
  • Modular Sensor Design
    Replaceable sensor module for easy maintenance and multi-gas flexibility.
  • Large LED Display
    High-brightness large digital LED screen ensures clear and easy reading from a distance.
  • Infrared Remote Control
    Supports IR remote operation for convenient parameter configuration.
  • Plug-and-Play Power Supply
    Online power supply design reduces wiring complexity and enables fast deployment.
  • Wireless Connection to Alarm Controller
    Detector data can be transmitted wirelessly to the alarm host, eliminating the need for field cabling.

 

Technical Parameters

Detection principle Electrochemical, catalytic combustion, infrared, semiconductor, heat conduction, PID photoion, etc.
Sampling method Natural diffusion
Ambient temperature -40℃ to 70℃(combustible gas), -20℃ to 50℃(toxic gases0
Relative humidity ≤ 93%
Explosion-proof method Flameproof type
Power supply AC220V 
Switch quantity Two sets of pulse relay outputs (adjustable for connecting to the fan)
Power consumption ≤ 5W
Whole machine weight ≤ 1000g
Pressure limit 86kPa to 106kPa
Explosion-proof mark Ex ia IIC T6 Ga
Explosion-proof certificate number CLEx24.1033X
Explosion-proof grade IP66

 

Common Gas Parameter listing
Gas detected Measuring Range Optional Range Resolution Rat Response Time
LEL -combustible gas 0-100%LEL 0-100%VOL(Infrared or catalytic οΌ‰ 1%LEL/1%vol ≤10s
 carbon monoxide 0-1000PPm 0-500/2000/5000PPm 0.1/1PPm ≤10s
TVOC 0-100PPM 0-100PPM 0.1PPm/1PPM ≤15s
hydrogen 0-100%LEL 0-1000PPM 1%LEL/1PPM ≤15s
natural gas 0-100%LEL 0-100%LEL 1%LEL ≤10s
Oxygen-O2 0-30%VOL 0-30%、0-100%VOL 0.1%vol ≤10s
ozone 0-10PPm 0-20、100PPm 0.01PPm/0.1PPM ≤15s
hydrogen sulfide-H2S 0-100PPm 0-50、200、1000PPm 1/0.1PPm ≤10s
Methane-CH4 0-100%LEL 0-100%VOL 1%LEL/1%vol ≤10s
fluorine 0-10PM 0-1、10PPM 1/0.1PPm ≤15s
hydrogen chloride 0-20PPm 0-20/50PPm/100PPM 0.01/0.1PPm ≤15s
Nitrogen-N2 0-30%VOL 0-30%VOL、100%VOL 0.1%LEL/1PPM ≤10s
hydrogen 0-100%LEL 0-1000PPm 1%LEL/0.1PPm ≤15s
chlorine 0-20PPm 0-10、100PPm 0.1PPm ≤15s
ammonia gas 0-100PPm 0-50、500、1000PPm 1/0.1PPm ≤15s
oxynitride 0-20PPm 0-50、1000PPm 0.1/1PPm ≤15s
methanal 0-20PPm 0-50、100PPm 1/0.1PPm ≤15s
sulfur dioxide 0-20PPm 0-50、1000PPm 0.1/1PPm ≤15s
nitric oxide 0-250PPm 0-500、1000PPm 1PPm ≤15s
nitrogen dioxide 0-20PPm 0-50、1000PPm 0.1/1PPm ≤15s
 phosphine 0-20PPm 0-20、100PPm 0.1PPm ≤15s
acrylonitrile 0-100PPM 0-100PPm 0.1/1PPm ≤15s
carbon dioxide 0-5000PPm 0-1%/5%/10%VOL(Infrared ) 1PPM/0.01%VOL ≤15s
hydrogen fluoride 0-10PPm 0-1、10、50、100PPM 0.01/0.1PPm ≤15s
Xylene/methylbenzene 0-20PPm 0-5、10、50、100PPm 0.01/0.1PPm ≤15s
oxirane 0-100PPm 0-100PPm 1/0.1PPm ≤15s


 Inquiry - ZADETECTOR GTYQ-QD6390 Independent gas detector