Share:


ZADETECTOR Zhongan S105 gas detector adopts the mixed technology of two-wire signal and power supply, wiring only needs 2 wires, no positive and negative wiring is convenient, the detector integrates sound and l

Specifications

SKU: ZADETECTOR Zhongan S105 gas detector adopts the mixed technology of two-wire signal and power supply, wiring only needs 2 wires, no positive and negative wiring is convenient, the detector integrates sound and l

Detection gas combustible/toxic and harmful gas (see attached table)
Detection method natural diffusion
Detection principle catalysis; electrochemistry; semiconductor; infrared
Detection range (3~100%) LEL; 0-****PPM
Zhongan GTYQ-S105 gas detector adopts the mixed technology of two-wire signal and power supply, wiring only needs 2 wires, no positive and negative wiring is convenient, the detector integrates sound and light display in one, wireless remote control debugging parameters, and real-time display monitoring On-site gas concentration, safe and simple without opening the cover.
Zhongan GTYQ-S105 point-type gas detector can convert the signal of gas concentration in the air into electric signal for remote transmission. The instrument has the advantages of long transmission distance, anti-interference, high sensitivity and fast response time.

Functions Features

Henan Zhong An Electronic Detection Technology CO.,LTD.Henan Zhong An Electronic Detection Technology CO.,LTD.Henan Zhong An Electronic Detection Technology CO.,LTD.

Technical Parameters

Detection gas Combustible/toxic and harmful gas (see attached table)
Detection method Natural diffusion
Detection principle Catalysis; electrochemistry; semiconductor; infrared
Detection range (3~100%) LEL; 0-****PPM
Resolution 1% LEL; 1PPM/0.1PPM
Display LCD display, LED display
Battery DC24V
Response time flammable: <15s; toxicity: <60s
Working environment -40℃~70℃(combustible gas);-20℃~50℃(toxic gas)
Relative humidity ≤93%RH
Alarm mode sound and light alarm
Debugging method manipulator
 Output signal two-wire system
Power consumption ≤3W
Explosion-proof certificate number CLEx24.1033X 
Explosion-proof grade Ex ia IIC T6 Ga
Protection level IP65
 size (182×175×73)mm
Instrument weight 1500g
Maximum distance between detector and host ≤1000m
 
 
Common Gas Parameter listing
Gas detected Measuring Range Optional Range Resolution Rat Response Time
LEL -combustible gas 0-100%LEL 0-100%VOL(Infrared or catalytic ) 1%LEL/1%vol ≤10s
 carbon monoxide 0-1000PPm 0-500/2000/5000PPm 0.1/1PPm ≤10s
TVOC 0-100PPM 0-100PPM 0.1PPm/1PPM ≤15s
hydrogen 0-100%LEL 0-1000PPM 1%LEL/1PPM ≤15s
natural gas 0-100%LEL 0-100%LEL 1%LEL ≤10s
Oxygen-O2 0-30%VOL 0-30%、0-100%VOL 0.1%vol ≤10s
ozone 0-10PPm 0-20、100PPm 0.01PPm/0.1PPM ≤15s
hydrogen sulfide-H2S 0-100PPm 0-50、200、1000PPm 1/0.1PPm ≤10s
Methane-CH4 0-100%LEL 0-100%VOL 1%LEL/1%vol ≤10s
fluorine 0-10PM 0-1、10PPM 1/0.1PPm ≤15s
hydrogen chloride 0-20PPm 0-20/50PPm/100PPM 0.01/0.1PPm ≤15s
Nitrogen-N2 0-30%VOL 0-30%VOL、100%VOL 0.1%LEL/1PPM ≤10s
hydrogen 0-100%LEL 0-1000PPm 1%LEL/0.1PPm ≤15s
chlorine 0-20PPm 0-10、100PPm 0.1PPm ≤15s
ammonia gas 0-100PPm 0-50、500、1000PPm 1/0.1PPm ≤15s
oxynitride 0-20PPm 0-50、1000PPm 0.1/1PPm ≤15s
methanal 0-20PPm 0-50、100PPm 1/0.1PPm ≤15s
sulfur dioxide 0-20PPm 0-50、1000PPm 0.1/1PPm ≤15s
nitric oxide 0-250PPm 0-500、1000PPm 1PPm ≤15s
nitrogen dioxide 0-20PPm 0-50、1000PPm 0.1/1PPm ≤15s
 phosphine 0-20PPm 0-20、100PPm 0.1PPm ≤15s
acrylonitrile 0-100PPM 0-100PPm 0.1/1PPm ≤15s
carbon dioxide 0-5000PPm 0-1%/5%/10%VOL(Infrared ) 1PPM/0.01%VOL ≤15s
hydrogen fluoride 0-10PPm 0-1、10、50、100PPM 0.01/0.1PPm ≤15s
Xylene/methylbenzene 0-20PPm 0-5、10、50、100PPm 0.01/0.1PPm ≤15s
oxirane 0-100PPm 0-100PPm 1/0.1PPm ≤15s


 Inquiry - ZADETECTOR Zhongan S105 gas detector adopts the mixed technology of two-wire signal and power supply, wiring only needs 2 wires, no positive and negative wiring is convenient, the detector integrates sound and l