Specifications
SKU: FUZRR ES100R Series Rogowski Coil Current Sensor
●ES Series Rogowski Coil Sensor
| Model | ES100R | ES200R | ES300R |
|---|---|---|---|
| Coil Length | 315mm | 630mm | 950mm |
| Coil Inside Dia | φ100mm | φ200mm | φ300mm |
| Coil weight | About 230g | About 250g | About 270g |
| Model | A | B | C | D | E |
|---|---|---|---|---|---|
| Output Signal | AC:1V/1A AC:1V/10A AC:1V/100A | AC:1V/100A AC:1V/1000A AC:1V/10 kA | DC:4~20mA/100A DC:4~20mA/1000A DC:4~20mA/10kA | AC:3V/100A AC:3V/1000A AC:3V/10kA | DC:10V/100A DC:10V/1000A DC:10V/10kA |
| Coil Color | Black | Blue | Blue | Blue | Blue |
| Battery | 9V Dry battery | 9V Dry battery | N/A | 9V Dry battery | N/A |
| External Power | External power | External power | External power | External power : | External power t: |
| Supply | 8~12V | 8~12V | input : 24V | 8~12V | 24V |
| Power Consumption | 6mA | 6mA | 10mA | 6mA | 10mA |
| Standard Interface | BNC | BNC | BNC | BNC | BNC |
| Function | AC leakage current, high current, high harmonic current, complex waveform current, transient impulse current phase, electric power, power, power factor, etc. |
| Test Method | Flexible CT: The output signal is the differential of current vs. time. By integrating the output voltage signal, the input current can be truly restored. |
| Coil Line Dia. | φ8mm |
| Output | Only coil output:100mV/1000A , see the output for details of the supporting Integrator |
| Power Supply Voltage | Corresponding Integrator power supply voltage |
| Low Current Indication | Have |
| Accuracy Level | ±1.0% FS ( 23 ℃ ± 2° C, 70% RH or less, the wire is at the center of the coil) |
| Phase Error | ≤1°(50Hz/60Hz ; 23°C±2°C) |
| Output Interface | BNC connector (optional audio plug, banana plug, bare wire) |
| Output Line Length | Pliers to adapter 50cm, signal output 2m |
| Electric Field Interference | Hysteresis effect, strong resistance to external electric field interference |
| Conductor Position | The tested wire is in the center of the coil, position error affects ≤±0.5% FS (1cm away from the port position) |
| Response Frequency | Without integrator: 0.1Hz ~ 10MHz , matched integrator: 0.1Hz ~ 1MHz |
| Line Voltage | Circuit test below AC 1000V |
Inquiry - FUZRR ES100R Series Rogowski Coil Current Sensor