Share:


ZADETECTOR S520 Plant Boundary Air Pollution Factor Monitoring System

Specifications

SKU: ZADETECTOR S520 Plant Boundary Air Pollution Factor Monitoring System

Detection Parameter Volatile organic compounds, sulfur dioxide, nitrogen oxides, hydrogen chloride, hydrogen sulfide, ammonia (optional based on actual needs)
Detection Principle PID photoionization, electrochemical, infrared
Detection Range, Resolution and Principle TVOC: 0 - 50ppm, 0.01ppm, PID photoionization principle                        SO2: 0 - 100ppm, 0.01ppm, electrochemical principle
NOx: 0 - 100ppm, 0.01ppm, electrochemical principle                                HCL: 0 - 100ppm, 0.01ppm, electrochemical principle
H2S: 0 - 100ppm, 0.01ppm, electrochemical principle                                 NH3: 0 - 100ppm, 0.01ppm, electrochemical principle
The Zhong'an S520 type factory boundary air pollution factor monitoring system utilizes the diffusion movement of air pollution factors (waste gas, toxic gas and dust), and adopts gas or dust sensor signal analysis technology. It can monitor air pollution factors (waste gas, toxic gas and dust) in real time, can replace manual detection methods, meet the purpose of all-weather unmanned monitoring of pollutants, provide real-time monitoring data, trend changes, alarm information and other functions. The monitoring data is transmitted in real time to the local environmental protection bureau platform or other cloud platforms through the wireless transmission module, and meteorological parameters can also be integrated at the same time.

 

The Zhong'an S520 type factory boundary air pollution factor monitoring system adopts internationally renowned high-precision sensors, with a built-in suction pump working mode, fast response time; high precision; long lifespan; wide range of detectable gases; strong anti-interference ability and other characteristics. It has standard output signals such as 4-20mA, RS485/M-BUS, which can be easily integrated with the monitoring system. Two-level switch output; on-site LCD display, external adjustment and setting by infrared remote control; it can remotely transmit the gas in the environment as an electrical signal, and transmit the signal to the secondary instrument. This sensor can be directly uploaded to the computer or connected to the DCS system. It can also be connected to the local environmental protection bureau's environmental monitoring platform to achieve continuous remote monitoring of gas concentrations in the environment.

 

The Zhong'an S520 type factory boundary air pollution factor monitoring system product has functions such as on-site buzzer indication sound, on-site flashing indication, etc., and displays the gas concentration at the monitoring site in real time. The entire process is automated and does not require human intervention.

Functions Features

Henan Zhong An Electronic Detection Technology CO.,LTD.

Henan Zhong An Electronic Detection Technology CO.,LTD.

 

 

Technical Parameters

Detection Parameter Volatile organic compounds, sulfur dioxide, nitrogen oxides, hydrogen chloride, hydrogen sulfide, ammonia (optional based on actual needs)
Detection Principle PID photoionization, electrochemical, infrared
Detection Range, Resolution and Principle TVOC: 0 - 50ppm, 0.01ppm, PID photoionization principle                        SO2: 0 - 100ppm, 0.01ppm, electrochemical principle
NOx: 0 - 100ppm, 0.01ppm, electrochemical principle                                HCL: 0 - 100ppm, 0.01ppm, electrochemical principle
H2S: 0 - 100ppm, 0.01ppm, electrochemical principle                                 NH3: 0 - 100ppm, 0.01ppm, electrochemical principle
Sensor Lifespan 2 years for PID photoionization, 2 - 3 years for electrochemical
Working Method Fixed installation, online detection, diffusion measurement, optional for pipeline type, flow type, and pump suction type.
Sampling Method Natural diffusion; pump suction
Indicated Value Error ± 3% FS
Repeatability The relative standard deviation should not be greater than 3%
Response Time T90 ≤ 30 s
Pump Suction Flow 2 liters/minute (standard)
Status Indication Sound, stroboscopic light
Debugging Method Remote control (display type function)
Display Method 7-inch color LCD screen
Alarm Method 1 or 2 passive contact signal outputs, alarm points can be set.
Ambient Temperature - 10℃ to 55℃
Relative Humidity ≤ 90% RH (non-condensing occasion), customization or optional pretreatment system is required for use in higher humidity environments
Power Supply AC220V ± 10%
Output Signal 4 - 20mA, RS485, relay (passive)
Power Consumption ≤ 100W
Installation Method Pole mounting
Pressure Limit 86kPa - 106kPa
Overall Dimensions Height 800mm * Width 560mm * Thickness 300mm


 Inquiry - ZADETECTOR S520 Plant Boundary Air Pollution Factor Monitoring System