Nominal diameter (mm)
15, 20, 25, 40, 50, 65, 80, 100, 125, 150, 200, 250.300, (300~1000 plug-in)
Nominal pressure (MPa) DN15-DN200 4.0(>4.0 protocol supply)DN250-DN3001.61(>1.6 protocol supply)
Main material 1Cr18Ni9Ti(Other materials supplied by agreement)

Vortex flowmeter is a volume flowmeter developed and produced based on the Karman vortex street principle to measure the volume flow rate, standard volume flow rate or mass flow rate of gas, steam or liquid. It is mainly used for flow measurement of industrial pipeline media fluids, such as gases, liquids, steam and other media. It can also measure turbid liquids containing fine particles and impurities. It is widely used in petroleum, chemical industry, pharmaceuticals, papermaking, metallurgy, electric power, environmental protection, food and other industries

Functions Features

Henan Zhong An Electronic Detection Technology CO.,LTD.

Henan Zhong An Electronic Detection Technology CO.,LTD.

Henan Zhong An Electronic Detection Technology CO.,LTD.

Technical Parameters

Nominal diameter (mm)
15, 20, 25, 40, 50, 65, 80, 100, 125, 150, 200, 250.300, (300~1000 plug-in)
Nominal pressure (MPa)
DN15-DN200 4.0(>4.0 protocol supply)DN250-DN3001.61(>1.6 protocol supply)
Main material
1Cr18Ni9Ti(Other materials supplied by agreement)
precision
+1%R, ±1.5%R; Plug-in :±2.5%R
Output signal
Square wave pulse (excluding battery powered type): high level > supply voltage minus 1V, low level ≤1V current :4~20mA
Intrinsic safety parameter
Ui=28VDC/li=100mA/Pi=0.657WCi=0.UF, Li=OmH
Environmental condition
Temperature -20%C~55℃; Relative humidity 5%~90% gas, liquid, steam atmospheric pressure 86~106kPa
Explosion-proof mark
EXiallCT4 Ga
Allowable vibration acceleration
Piezoelectric type :0.2g; Capacitive :1.0~2.0g
Supply voltage
Sensor:DC24V(DC) Battery powered type:3.6V battery
Pressure loss coefficient
Conforms to JB/T9249 standard Cds2.4
Protection class
Ordinary type IP65; Submersible type IP68
Applicable medium
Gas, liquid, steam
 
 
Transmission distance
Three wire pulse output type :S300m;
Two-wire standard current output type (4~20mA)≤1500m: Load resistance≤ S500Ω;
RS485≤1200m

 

Electromagnetic Flowmeter Electrode Material
Materials Corrosion Property
316L Electrode Application: Domestic/ industrial water, sewage PH in the range of :6/7/8;
Not Application: hydrofluoric acid/ hydrochloric acid/ chlorine/ iodine and other corrosive media
HB Application: Non-oxidizing acids such as hydrofluoric acid and non-oxidizing hydrochloric acid of a certain concentration, alkali solutions such as sodium hydroxide with a concentration of  ≥70%. PH value is within the range of: 5/6/7/8 ;Not applicable: oxidizing acids such as nitric acid
HC Application: Resistance to oxidizing salts or environmental corrosion containing other oxidants, particularly good resistance to seawater.
PH in the range of: 6/7/8/9; Not applicable: Reducing acids such as hydrochloric acid, dilute sulfuric acid, phosphoric acid and chlorides
Ti Application: chlorides, hypochlorites, seawater, oxidizing acids. PH: 6/7/8/9/10 range;
Not applicable: hydrochloric acid, sulfuric acid and other acidic media
Ta Application: concentrated hydrochloric acid, nitric acid, sulfuric acid and most other acids, including boiling point hydrochloric acid, nitric acid.
PH in the range of: 3/4/5/6;Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid
Pt All kinds of acids, bases, salts. Not included: Aqua Regia
Materials Corrosion Property
316L Electrode Application: Domestic/ industrial water, sewage PH in the range of :6/7/8;
Not Application: hydrofluoric acid/ hydrochloric acid/ chlorine/ iodine and other corrosive media
HB Application: Non-oxidizing acids such as hydrofluoric acid and non-oxidizing hydrochloric acid of a certain concentration, alkali solutions such as sodium hydroxide with a concentration of  ≥70%. PH value is within the range of: 5/6/7/8 ;Not applicable: oxidizing acids such as nitric acid
HC Application: Resistance to oxidizing salts or environmental corrosion containing other oxidants, particularly good resistance to seawater.
PH in the range of: 6/7/8/9; Not applicable: Reducing acids such as hydrochloric acid, dilute sulfuric acid, phosphoric acid and chlorides
Ti Application: chlorides, hypochlorites, seawater, oxidizing acids. PH: 6/7/8/9/10 range;
Not applicable: hydrochloric acid, sulfuric acid and other acidic media
Ta Application: concentrated hydrochloric acid, nitric acid, sulfuric acid and most other acids, including boiling point hydrochloric acid, nitric acid.
PH in the range of: 3/4/5/6;Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid
Pt All kinds of acids, bases, salts. Not included: Aqua Regia

 

Lining Material
Material Main Performance
Polyurethane rubber

1: good wear resistance of coal slurry, mud, pulp, etc.

2: no acid, alkali and other corrosive or high temperature media
3: There can be no negative pressure in the pipeline

Neoprene rubber

1: good elastic wear resistance

2: can measure domestic sewage, non-corrosive industrial sewage.
PH value in the range of 6/7/8;temperature below 80℃ liquid;

3: there can be no negative pressure in the pipeline

Polytetrafluoroethylene F-4 PTFE

1: Resistance to boiling hydrochloric acid, sulfuric acid, nitric acid, aqua regis, concentrated alkali and various organic solutions
2: strong wear resistance, poor bonding performance

3: there can be no negative pressure in the pipeline

   
Perchlorinated ethylene Propylene F-46(PTFE)

1: On the basis of all the functions of PTFE, the non-corrosive liquid temperature can be increased within 140 degrees
2: No smoking nitric acid, butyl lithium

3: no negative pressure in the pipeline

Silicone fluorine lining Temperature resistance: 70 °, can withstand high temperature. And can be used for heating system hot water measurement, with basic corrosion resistance.

 

Flow Rate and Flow Velocity Comparison Table

Velocity of flow
Flow rate

(m/s)
(m/h)
Oral diameter
(mm)

0.1 0.2 0.4 0.5  1 10 12 15
 10 0.03 0.06 0.11 0.14 0.28 2.827 3.39 4.24
 15 0.06 0.127 0.25 0.32 0.64 6.362 7.63 9.54
 20 0.13 0.226 0.45 0.57 1.13 11.31 13.57 16.97
 25 0.18 0.35 0.71 0.88 1.77 17.67 21.20 26.51
 32 0.29 0.58 1.16 1.45 2.90 28.95 34.75 43.43
 40 0.45 0.90 1.81 2.62 4.52 45.24 54.21 67.86
 50 0.71 1.414 2.83 3.54 7.07 70.69 84.83 106.00
 65 1.195 2.39 4.78 5.97 11.95 119.50 143.35 179.20
 80 1.81 3.62 7.24 9.05  18.1 181 217.2 271.5
 100 2.83 5.65 11.31 14.14 28.27 282.7 339.24 424.05
 125 4.42 8.84 17.67 22.09 44.18 441.8 530.16 662.7
 150 6.36 12.7  25.5 31.81 63.62 636.2 763.44 954.3
 200 11.3 22.6  45.2 45.55 113.1  1131 1357.2 1696.5
 250 17.7 35.4  70.7 88.36 176.7  1767 2110.4 2650.5
 300 25.45 51 102 127.24 254.5  2545 3054 3878.5
 350 34.64 69 139 173.2 356.4  3464 4156.8 5196
 400 45.24 90 181 226.2 452.4  4524 5428.8 6786
 450 57.3 114 229 286.3 572.6  5726 6871.2 8589
 500 70.7 141 283 353.4 706.9  7069 8484.8 10603.5
600 102 203 407 508.9 1018  10179 12216 15270
 700 139 277  554 692.7 1385  13854 16620 20775
 800 181.0 362 723 905 1810  18096 21720 27150
 900 229.0 458 916 1145 2290  22902 27480 34350
 1000 283 565  1131 1414 2827 28274 33924  42405
1200 407 814 1628 2034.7 4069.4 40694 48832.8 61041
1400 554 1108 2216 2769.5 5539.4 55390 66468 83085
1600 723 1447 2894 3617.3  7234.6 72346 86815.5  108519

 

External Shape and Installation Dimensions
Nominal Diameter(mm) Nominal Pressure(MPa) Overall Dimension Reference Weight(kg)
Meter Length (including lining) D H
6 1.6 200 90 220 6
10 200 90 220 6
15 200 95 220 8
20 200 105 220 10
25 200 115 223 12
32 200 140 240 13
40 200 150 250 14
50 200 165 263 15
65 200 185 283 18
80 200 200 290 20
100 250 235 318 25
125 250 270 350 28
150 300 300 380 30
200 350 340 430 50
250 450 405 495 70
300 500 460 547 95
350 1.0 500 520 602 120
400 500 580 665 140
450 550 640 720 160
500 550 715 783 200