Share:


DATATEST ITC Series ITC Series Industrial Dry Wells

Specifications

SKU: DATATEST ITC Series ITC Series Industrial Dry Wells

Brief introduction:
The ITC series industrial dry block calibrators are highly portable and easy to operate, while offering excellent accuracy and performance at a relatively affordable price. ITC Series Industrial Dry Block Product Description: The JOFRA ITC series industrial dry block temperature calibrators are highly portable and easy to operate, while offering excellent accuracy and performance at a relatively affordable price. ITC Series Industrial Dry Block Product Performance: The ITC series temperature calibrators adopt a robust and lightweight design similar to the CTC series. The panel design is simple and intuitive, using an LCD screen. The internal design incorporates technologies such as dual-zone heating and MVI. These features make the ITC suitable for both field and laboratory use. The ITC series includes three models, each corresponding to a different temperature range. All models have an RS232 interface, and JOFRACAL calibration software is included as standard.
Details:
The ITC series industrial dry block calibrators are highly portable and easy to operate, while offering excellent accuracy and performance at a relatively affordable price.
ITC Series Industrial Dry Block Product Description:
The JOFRA ITC series industrial dry block temperature calibrators are highly portable and easy to operate, while offering excellent accuracy and performance at a relatively affordable price.

ITC Series Industrial Dry Block Product Performance:
The ITC series temperature calibrators adopt a robust and lightweight design similar to the CTC series. The panel design is simple and intuitive, using an LCD screen. The internal design incorporates technologies such as dual-zone heating and MVI. These features make the ITC suitable for both field and laboratory use.
The ITC series includes three models, each corresponding to a different temperature range. All models have an RS232 interface, and JOFRACAL calibration software is included as standard.
ITC series industrial dry well temperature range:
ITC-155 -23°  C 155°C
ITC-320 33  320°C
ITC-650 33  650°C

Improved temperature consistency:
The unique dual-zone design ensures temperature consistency in the calibration areas for heating or cooling .
Enhanced stability:
The MVI circuitry guarantees temperature stability during power supply voltage fluctuations .
Time-saving calibration:
Rapid operation with automatic switching tests and automatic stepping functions.
Data processing capabilities:
RS232 communication interface and  JOFRACAL  software are standard features .

ITC-320 and ITC-650 dual-zone heating modules.

The dual-zone heating design significantly improves temperature consistency across the calibration area. The lower heating zone ensures appropriate heat dissipation for the entire heating block , while the upper heating zone compensates for heat loss from the upper part of the heating element and the sensor under test This design eliminates the need for heat insulation of the probe under test and can calibrate liquid-filled or other mechanical probes .
Switch test Type only ) .

The calibrator can perform temperature switch tests automatically recording the on off points and dead zones and can retain data from five tests However, this data cannot be uploaded to a computer it can only be stored in the calibrator .
Automatic stepping...

Up to 20 automatic stepping steps can be set including the hold time for each step After completing an automatic stepping cycle the user can easily read the test data of the probe under test . Up to sets of automatic stepping test data can be stored MVI improves temperature stability.

MVI stands for "Mains Power Variance Immunity," meaning power fluctuation elimination .  Unstable power supply is a major cause of inaccuracies in field calibrators .  Typical calibrators are unstable in the field due to frequent start-ups and shutdowns of large motors or other equipment , leading to power instability Power fluctuations cause temperature controller instability resulting in reading errors and temperature fluctuations . The JOFRA ITC uses MVI technology to avoid this instability problem . The MVI circuit constantly monitors the supply voltage and ensures a stable energy supply to the heating element Other ITC models operate on regulated DC voltage and therefore do not require an MVI circuit for stable operation (Stability indicator)

Once the calibrator reaches and stabilizes at the set temperature, a bold checkmark will appear on the screen. The operator can adjust the stabilization conditions to achieve more stringent calibration results. A *** indicator will appear minutes before the calibrator reaches stabilization, indicating the time required.
Simplified calibration documentation.

All ITC series calibrators come standard with JOFRACAL software This Windows- based software allows for the setup of the calibration process It is very easy to use requiring no programmers to easily configure calibration steps . The software provides prompts menus, and help functions during setup .
The required calibration work can be stored in a work order file and downloaded from the computer to the calibrator via the RS232 interface .
ITC Series Industrial Dry Well Selection Table

 
model ITC-15  ITC-320A  ITC-650A 
Temperature range
(ambient temperature 23℃)
 -23℃~ 155℃  33℃~ 320℃  33℃~ 650℃
Accuracy ±0.18 ℃  ±0.25℃  ±0.45℃ 
Stability ±0.01℃  ±0.02℃  ±0.04℃ 
Display resolution 0.1℃  0.1℃  0.1℃ 
Insertion depth 160mm  160mm  160mm 
Insertion sleeve diameter 20mm  30mm  30mm 
heating time
(Room temperature to high temperature)
14 minutes 7 minutes 25 minutes
Cooling time
(from high temperature to 100℃)
4 minutes 30 minutes 56 minutes
Automatic stepping √  √  √ 
Automatic switch test √  √  √ 
RS232 interface √  √  √ 
Standard software √  √  √ 
Dual-zone heating  - √  √ 
MVI  - √  √ 
Instrument dimensions (length × width × height)  241×139×375mm  241×139×375mm  241×139×375mm 
weight 7.6kg  6.5kg  8.5kg 
Standard configuration The package includes a calibrator, software, communication cable, one sleeve, power cord, instruction manual, and factory calibration certificate. (The ETC-400R includes an emissivity meter and carrying case; the sleeve is built-in.)
Options Various types of sleeves, portable cases.


 Inquiry - DATATEST ITC Series ITC Series Industrial Dry Wells