Share:


DATATEST ITC Series ITC Series Industrial Dry Wells



Specifications

SKU: DATATEST ITC Series ITC Series Industrial Dry Wells

Brief introduction:
The ITC series industrial dry block calibrators are highly portable and easy to operate, while offering excellent accuracy and performance at a relatively affordable price. ITC Series Industrial Dry Block Product Description: The JOFRA ITC series industrial dry block temperature calibrators are highly portable and easy to operate, while offering excellent accuracy and performance at a relatively affordable price. ITC Series Industrial Dry Block Product Performance: The ITC series temperature calibrators adopt a robust and lightweight design similar to the CTC series. The panel design is simple and intuitive, using an LCD screen. The internal design incorporates technologies such as dual-zone heating and MVI. These features make the ITC suitable for both field and laboratory use. The ITC series includes three models, each corresponding to a different temperature range. All models have an RS232 interface, and JOFRACAL calibration software is included as standard.
Details:
The ITC series industrial dry block calibrators are highly portable and easy to operate, while offering excellent accuracy and performance at a relatively affordable price.
ITC Series Industrial Dry Block Product Description:
The JOFRA ITC series industrial dry block temperature calibrators are highly portable and easy to operate, while offering excellent accuracy and performance at a relatively affordable price.

ITC Series Industrial Dry Block Product Performance:
The ITC series temperature calibrators adopt a robust and lightweight design similar to the CTC series. The panel design is simple and intuitive, using an LCD screen. The internal design incorporates technologies such as dual-zone heating and MVI. These features make the ITC suitable for both field and laboratory use.
The ITC series includes three models, each corresponding to a different temperature range. All models have an RS232 interface, and JOFRACAL calibration software is included as standard.
ITC series industrial dry well temperature range:
ITC-155 -23°  C 155°C
ITC-320 33  320°C
ITC-650 33  650°C

Improved temperature consistency:
The unique dual-zone design ensures temperature consistency in the calibration areas for heating or cooling .
Enhanced stability:
The MVI circuitry guarantees temperature stability during power supply voltage fluctuations .
Time-saving calibration:
Rapid operation with automatic switching tests and automatic stepping functions.
Data processing capabilities:
RS232 communication interface and  JOFRACAL  software are standard features .

ITC-320 and ITC-650 dual-zone heating modules.

The dual-zone heating design significantly improves temperature consistency across the calibration area. The lower heating zone ensures appropriate heat dissipation for the entire heating block , while the upper heating zone compensates for heat loss from the upper part of the heating element and the sensor under test . This design eliminates the need for heat insulation of the probe under test and can calibrate liquid-filled or other mechanical probes .
Switch test ( Type B only ) .

The calibrator can perform temperature switch tests , automatically recording the on / off points and dead zones , and can retain data from five tests . However, this data cannot be uploaded to a computer ; it can only be stored in the calibrator .
Automatic stepping...

Up to 20 automatic stepping steps can be set , including the hold time for each step . After completing an automatic stepping cycle , the user can easily read the test data of the probe under test . Up to 5 sets of automatic stepping test data can be stored . MVI improves temperature stability.

MVI stands for "Mains Power Variance Immunity," meaning power fluctuation elimination .  Unstable power supply is a major cause of inaccuracies in field calibrators .  Typical calibrators are unstable in the field due to frequent start-ups and shutdowns of large motors or other equipment , leading to power instability . Power fluctuations cause temperature controller instability , resulting in reading errors and temperature fluctuations . The JOFRA ITC uses MVI technology to avoid this instability problem . The MVI circuit constantly monitors the supply voltage and ensures a stable energy supply to the heating element . Other ITC models operate on regulated DC voltage and therefore do not require an MVI circuit for stable operation . (Stability indicator)

Once the calibrator reaches and stabilizes at the set temperature, a bold checkmark will appear on the screen. The operator can adjust the stabilization conditions to achieve more stringent calibration results. A *** indicator will appear 5 minutes before the calibrator reaches stabilization, indicating the time required.
Simplified calibration documentation.

All ITC series calibrators come standard with JOFRACAL software . This Windows- based software allows for the setup of the calibration process . It is very easy to use , requiring no programmers to easily configure calibration steps . The software provides prompts , menus, and help functions during setup .
The required calibration work can be stored in a " work order " file and downloaded from the computer to the calibrator via the RS232 interface .
ITC Series Industrial Dry Well Selection Table

 
model ITC-15  ITC-320A  ITC-650A 
Temperature range
(ambient temperature 23℃)
 -23℃~ 155℃  33℃~ 320℃  33℃~ 650℃
Accuracy ±0.18 ℃  ±0.25℃  ±0.45℃ 
Stability ±0.01℃  ±0.02℃  ±0.04℃ 
Display resolution 0.1℃  0.1℃  0.1℃ 
Insertion depth 160mm  160mm  160mm 
Insertion sleeve diameter 20mm  30mm  30mm 
heating time
(Room temperature to high temperature)
14 minutes 7 minutes 25 minutes
Cooling time
(from high temperature to 100℃)
4 minutes 30 minutes 56 minutes
Automatic stepping √  √  √ 
Automatic switch test √  √  √ 
RS232 interface √  √  √ 
Standard software √  √  √ 
Dual-zone heating  - √  √ 
MVI  - √  √ 
Instrument dimensions (length × width × height)  241×139×375mm  241×139×375mm  241×139×375mm 
weight 7.6kg  6.5kg  8.5kg 
Standard configuration The package includes a calibrator, software, communication cable, one sleeve, power cord, instruction manual, and factory calibration certificate. (The ETC-400R includes an emissivity meter and carrying case; the sleeve is built-in.)
Options Various types of sleeves, portable cases.