ERANNTEX Portable Composite Odor Gas Analyzer

Specifications

SKU: ERANNTEX Portable Composite Odor Gas Analyzer

Model:BTYQ-PTM600-OU
The Eranntex BTYQ-PTM600-OU Portable Composite Odor Gas Analyzer supports simultaneous detection of 1 to 18 gases, with flexible concentration units selectable from ppm, μmol/mol, mg/m³, %VOL, %LEL, pphm, and ppb. Its built-in pump-type measurement system features integrated moisture and dust filters, ensuring rapid response. The device is sprayproof, dustproof, and explosion-proof (intrinsically safe circuit design), and is resistant to vibration, static electricity, and electromagnetic interference. It offers three display modes: simultaneous display of four-channel gas concentrations, large-font single-channel loop readings, or a real-time concentration curve. Each channel supports automatic and manual looping, and can be customized to display maximum, minimum, or average values. It supports both real-time and timed detection modes.
Portable Composite Odor Gas Analyzer
 
  •  
  •  
  •  
  •  
 

Portable Composite Odor Gas Analyzer

Model:BTYQ-PTM600-OU
The Eranntex BTYQ-PTM600-OU Portable Composite Odor Gas Analyzer supports simultaneous detection of 1 to 18 gases, with flexible concentration units selectable from ppm, μmol/mol, mg/m³, %VOL, %LEL, pphm, and ppb. Its built-in pump-type measurement system features integrated moisture and dust filters, ensuring rapid response. The device is sprayproof, dustproof, and explosion-proof (intrinsically safe circuit design), and is resistant to vibration, static electricity, and electromagnetic interference. It offers three display modes: simultaneous display of four-channel gas concentrations, large-font single-channel loop readings, or a real-time concentration curve. Each channel supports automatic and manual looping, and can be customized to display maximum, minimum, or average values. It supports both real-time and timed detection modes.
 

The Eranntex BTYQ-PTM600-OU Portable Composite Odor Gas Analyzer features a multi-alarm system that supports audible, visual, vibration, or combined alarms, providing comprehensive status indication. It covers three trigger types: concentration threshold, undervoltage warning, and fault alarm. Alarm modes include low limit, high limit, range, and weighted average settings. The device features automatic zero-point tracking technology and multi-level calibration, effectively preventing zero-point drift caused by long-term use and automatically preventing concentration calibration errors. A factory reset function is standard, and optional features include an ambient temperature and humidity monitoring module and an RS485 communication interface. Other functional expansions and communication protocols support deep customization, and the device is fully open to OEM/ODM collaboration.

The Eranntex BTYQ-PTM600-OU Portable composite odor gas analyzer technical parameters

Parameter

Specification

Detected Gas

Odor Concentration (OU): 0-2000 (Resolution: 0.1)<br>Ammonia (NH₃): 0-50 ppm (Resolution: 0.001 ppm)<br>Hydrogen Sulfide (H₂S): 0-10 ppm (Resolution: 0.001 ppm)<br>Temperature: -40 to +120°C<br>Humidity: 0-100% RH

Detection Principle

Metal Semiconductor, Electrochemical

Typical Accuracy

≤±2% F.S. (higher accuracy customizable)

Linearity

≤±2%

Repeatability

≤±2%

Uncertainty

≤±2%

Response Time (T90)

≤20 seconds

Recovery Time

≤30 seconds

Operating Environment

Temp: -20℃ to +55℃ (typical), -40℃ to +70℃ (extreme)<br>Humidity: ≤95% RH (non-condensing)<br>High-temp sampling handle optional

Temp/Humidity (Optional)

Temp: -40℃~+70℃ (±0.5℃)<br>Humidity: 0–100% RH (±3% RH)

Power Supply

3.7 VDC, dual 5400 mAh rechargeable polymer batteries

Display

3.5-inch HD color screen, 8-key operation

Sampling Method

Built-in pump suction (500 ml/min flow rate)

Communication

USB (charging & data), optional RS485, infrared

Data Storage

100,000 data records standard (custom capacity available)

Protection Rating

IP66

Explosion Proof Rating

Intrinsically Safe: Exia II C T4 Ga

Dimensions

Standard: 255 × 210 × 125 mm (L×H×W)<br>Custom: 420 × 210 × 125 mm

Weight

3.2 kg (slight variations by configuration)

The Eranntex BTYQ-PTM600-OU Portable composite odor gas analyzer display interface

Portable Composite Odor Gas Analyzer

All-in-one interface

Portable Composite Odor Gas Analyzer

single gas interface

Portable Composite Odor Gas Analyzer

curve display interface

(The all-in-one interface is not available for single gas detection)

 

The Eranntex BTYQ-PTM600-OU Portable composite odor gas analyzer actual picture

Portable Composite Odor Gas Analyzer
Portable Composite Odor Gas Analyzer
Portable Composite Odor Gas Analyzer

The Eranntex BTYQ-PTM600-OU Portable composite odor gas analyzer optional accessories: (Optional accessories require additional charges)

Portable Composite Odor Gas Analyzer

High humidity filter

Portable Composite Odor Gas Analyzer

telescopic sampling handle

Portable Composite Odor Gas Analyzer

High-temperature sampling handle

(0.3m 400°C/0.7m 800°C/1.2m 1300°C; three sizes available)

List of some detectable gases (please consult sales engineers for gases not listed)

 

Detected Gas

Range(s)

Combustible Gas (EX)

0-100% LEL, 0-100% Vol

Methane (CH₄)

0-100% LEL, 0-100% Vol, 0-1000 ppm, 0-10000 ppm

Oxygen (O₂)

0-30% Vol, 0-100% Vol, 0-5000 ppm

Nitrogen (N₂)

0-100% Vol

Carbon Monoxide (CO)

0-100 ppm, 0-1000 ppm, 0-2000 ppm, 0-20000 ppm, 0-100000 ppm

Carbon Dioxide (CO₂)

0-500 ppm, 0-2000 ppm, 0-5000 ppm, 0-50000 ppm, 0-20% Vol, 0-100% Vol

Formaldehyde (CH₂O)

0-10 ppm, 0-100 ppm, 0-1000 ppm

Ozone (O₃)

0-1 ppm, 0-5 ppm, 0-50 ppm, 0-100 ppm, 0-2000 ppm, 0-30000 ppm

Hydrogen Sulfide (H₂S)

0-10 ppm, 0-50 ppm, 0-100 ppm, 0-2000 ppm, 0-10000 ppm

Sulfur Dioxide (SO₂)

0-10 ppm, 0-20 ppm, 0-100 ppm, 0-500 ppm, 0-2000 ppm, 0-10000 ppm

Nitric Oxide (NO)

0-10 ppm, 0-100 ppm, 0-2000 ppm, 0-5000 ppm

Nitrogen Dioxide (NO₂)

0-10 ppm, 0-100 ppm, 0-2000 ppm, 0-5000 ppm

Nitrogen Oxides (NOx)

0-10 ppm, 0-100 ppm, 0-2000 ppm, 0-5000 ppm

Chlorine (Cl₂)

0-10 ppm, 0-20 ppm, 0-200 ppm, 0-2000 ppm

Ammonia (NH₃)

0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-5000 ppm, 0-100% LEL

Hydrogen (H₂)

0-100% LEL, 0-1000 ppm, 0-20000 ppm, 0-40000 ppm, 0-100% Vol

Helium (He)

0-100% Vol

Argon (Ar)

0-100% Vol

Xenon (Xe)

0-100% Vol

Hydrogen Cyanide (HCN)

0-30 ppm, 0-100 ppm

Hydrogen Chloride (HCl)

0-20 ppm, 0-200 ppm

Phosphine (PH₃)

0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-4000 ppm

Chlorine Dioxide (ClO₂)

0-1 ppm, 0-10 ppm, 0-200 ppm

Ethylene Oxide (ETO)

0-100 ppm, 0-1000 ppm, 0-100% LEL

Phosgene (COCl₂)

0-1 ppm, 0-50 ppm

Silane (SiH₄)

0-1 ppm, 0-50 ppm

Fluorine (F₂)

0-1 ppm, 0-10 ppm, 0-50 ppm

Hydrogen Fluoride (HF)

0-10 ppm, 0-50 ppm

Hydrogen Bromide (HBr)

0-50 ppm

Diborane (B₂H₆)

0-10 ppm

Arsine (AsH₃)

0-1 ppm, 0-10 ppm, 0-50 ppm

Germane (GeH₄)

0-2 ppm, 0-20 ppm

Hydrazine (N₂H₄)

0-1 ppm, 0-300 ppm

Tetrahydrothiophene (THT)

0-100 mg/m³

Bromine (Br₂)

0-10 ppm, 0-100 ppm, 0-2000 ppm

Acetylene (C₂H₂)

0-100% LEL, 0-100 ppm, 0-1000 ppm

Ethylene (C₂H₄)

0-100% LEL, 0-100 ppm, 0-2000 ppm

Ethanol (C₂H₆O)

0-100 ppm, 0-2000 ppm, 0-100% LEL

Methanol (CH₄O)

0-100 ppm, 0-2000 ppm

Carbon Disulfide (CS₂)

0-50 ppm, 0-5000 ppm

Acrylonitrile (C₃H₃N)

0-50 ppm, 0-2000 ppm

Methylamine (CH₅N)

0-50 ppm

Iodine (I₂)

0-50 ppm

Styrene (C₈H₈)

0-10 ppm, 0-100 ppm, 0-200 ppm, 0-1000 ppm, 0-5000 ppm

Vinyl Chloride (C₂H₃Cl)

0-100 ppm, 0-1000 ppm

Trichloroethylene (C₂HCl₃)

0-100 ppm, 0-1000 ppm

Tetrachloroethylene (C₂Cl₄)

0-100 ppm, 0-1000 ppm

Nitrous Oxide (N₂O)

0-100 ppm

Nitrogen Trifluoride (NF₃)

0-100 ppm

Hydrogen Peroxide (H₂O₂)

0-100 ppm, 0-1000 ppm

Methyl Bromide (CH₃Br)

0-100 ppm, 0-30000 ppm, 0-200 g/m³

Sulfuryl Fluoride (SO₂F₂)

0-100 ppm, 0-5000 ppm, 0-10000 ppm

Benzene (C₆H₆)

0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-10000 ppm

Toluene (C₇H₈)

0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-10000 ppm

Xylene (C₈H₁₀)

0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-10000 ppm

VOC

0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-10000 ppm

TVOC

0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-10000 ppm

Non-Methane Total Hydrocarbons

0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-10000 ppm

Refrigerants

0-1000 ppm, 0-2000 ppm, 0-5000 ppm

Sulfur Hexafluoride (SF₆)

0-1000 ppm, 0-2000 ppm, 0-3000 ppm

 

Hot Tags: Portable Composite Odor Gas Analyzer


 Inquiry - ERANNTEX Portable Composite Odor Gas Analyzer