Specifications
SKU: ERANNTEX Portable Fire Gas Detector
The Eranntex Portable Fire Gas Detector's multiple alarm system supports audible, visual, vibration, or combined alarms, providing comprehensive status indication. It covers three trigger types: concentration threshold, undervoltage warning, and fault alarm. Alarm modes include low limit, high limit, range, and weighted average settings. The device features automatic zero-point tracking technology, effectively preventing zero-point drift caused by long-term use. The calibration system supports multi-level calibration and automatically prevents concentration calibration errors. A factory reset function is standard, and optional features include an ambient temperature and humidity monitoring module and an RS485 communication interface. Other functional expansions and communication protocols are fully customizable, and the device is fully open to OEM/ODM development.
The Eranntex Portable fire gas detector technical parameters
|
Parameter |
Specification |
|
Detected Parameters |
Methane (CH₄), Oxygen (O₂), Carbon Monoxide (CO), Sulfur Dioxide (SO₂), Hydrogen Sulfide (H₂S), Ambient Temperature & Humidity, Wind Speed |
|
Detection Range |
H₂S: 0-100 ppm, CO: 0-1000 ppm, CH₄: 0-100% LEL, O₂: 0-30% vol, SO₂: 0-100 ppm, <br>Temp (T): -40℃~+70℃, Humidity (H): 0–100% RH, Wind Speed (WS): 0-20 m/s |
|
Resolution |
H₂S: 0.01 ppm, CO: 0.1 ppm, CH₄: 0.1% LEL, O₂: 0.01% vol, SO₂: 0.01 ppm, <br>Temp (T): 0.1℃, Humidity (H): 1% RH, Wind Speed (WS): 0.1 m/s |
|
Detection Principle |
H₂S/CO/O₂/SO₂: Electrochemical; CH₄: Catalytic combustion; <br>Temp/Humidity: Capacitive chip; Wind Speed: Thermal anemometry |
|
Typical Accuracy |
≤±1% F.S. (Higher accuracy customizable) |
|
Linearity |
≤±1% |
|
Repeatability |
≤±1% |
|
Uncertainty |
≤±1% |
|
Response Time (T90) |
≤30 seconds |
|
Recovery Time |
≤30 seconds |
|
Operating Environment |
Temp: -20°C to +55°C (typical), -40°C to +70°C (extreme); <br>Humidity: ≤95% RH (non-condensing); <br>High-temp sampling handle optional for extreme conditions |
|
Temp/Humidity Spec |
Temp: -40°C~+70°C (±0.5°C); Humidity: 0–100% RH (±3% RH) |
|
Power Supply |
3.7 VDC, 6000 mAh rechargeable polymer battery |
|
Display |
2.5-inch color screen (320×240 resolution), 8-key operation |
|
Sampling Method |
Built-in pump suction (500 ml/min flow rate) |
|
Communication |
USB (charging & data), optional RS485, infrared |
|
Data Storage |
100,000 data records standard (custom capacity available) |
|
Protection Rating |
IP67 |
|
Explosion Proof Rating |
Intrinsically Safe: Exia II C T4 Ga / Exia D20 T130°C |
Inquiry - ERANNTEX Portable Fire Gas Detector