Share:


ERANNTEX Portable Fire Gas Detector

Specifications

SKU: ERANNTEX Portable Fire Gas Detector

Model:BTYQ-MS600
The Eranntex Portable Fire Gas Detector supports simultaneous detection of one to six gases, offering flexible concentration units such as ppm, μmol/mol, mg/m³, %VOL, %LEL, pphm, and ppb. Its built-in pump-type measurement system features integrated moisture and dust filters, ensuring rapid response. The detector is sprayproof, dustproof, and explosion-proof (intrinsically safe circuit design), and is resistant to vibration, static electricity, and electromagnetic interference. It offers three display modes: simultaneous display of six gas concentration channels, large-font single-channel loop readings, or a real-time concentration curve. Each channel supports automatic and manual looping, and users can customize the display of maximum, minimum, or average values. It supports both real-time and timed detection modes.

The Eranntex Portable Fire Gas Detector's multiple alarm system supports audible, visual, vibration, or combined alarms, providing comprehensive status indication. It covers three trigger types: concentration threshold, undervoltage warning, and fault alarm. Alarm modes include low limit, high limit, range, and weighted average settings. The device features automatic zero-point tracking technology, effectively preventing zero-point drift caused by long-term use. The calibration system supports multi-level calibration and automatically prevents concentration calibration errors. A factory reset function is standard, and optional features include an ambient temperature and humidity monitoring module and an RS485 communication interface. Other functional expansions and communication protocols are fully customizable, and the device is fully open to OEM/ODM development.

The Eranntex Portable fire gas detector technical parameters

Parameter

Specification

Detected Parameters

Methane (CH₄), Oxygen (O₂), Carbon Monoxide (CO), Sulfur Dioxide (SO₂), Hydrogen Sulfide (H₂S), Ambient Temperature & Humidity, Wind Speed

Detection Range

H₂S: 0-100 ppm, CO: 0-1000 ppm, CH₄: 0-100% LEL, O₂: 0-30% vol, SO₂: 0-100 ppm, <br>Temp (T): -40℃~+70℃, Humidity (H): 0–100% RH, Wind Speed (WS): 0-20 m/s

Resolution

H₂S: 0.01 ppm, CO: 0.1 ppm, CH₄: 0.1% LEL, O₂: 0.01% vol, SO₂: 0.01 ppm, <br>Temp (T): 0.1℃, Humidity (H): 1% RH, Wind Speed (WS): 0.1 m/s

Detection Principle

H₂S/CO/O₂/SO₂: Electrochemical; CH₄: Catalytic combustion; <br>Temp/Humidity: Capacitive chip; Wind Speed: Thermal anemometry

Typical Accuracy

≤±1% F.S. (Higher accuracy customizable)

Linearity

≤±1%

Repeatability

≤±1%

Uncertainty

≤±1%

Response Time (T90)

≤30 seconds

Recovery Time

≤30 seconds

Operating Environment

Temp: -20°C to +55°C (typical), -40°C to +70°C (extreme); <br>Humidity: ≤95% RH (non-condensing); <br>High-temp sampling handle optional for extreme conditions

Temp/Humidity Spec

Temp: -40°C~+70°C (±0.5°C); Humidity: 0–100% RH (±3% RH)

Power Supply

3.7 VDC, 6000 mAh rechargeable polymer battery

Display

2.5-inch color screen (320×240 resolution), 8-key operation

Sampling Method

Built-in pump suction (500 ml/min flow rate)

Communication

USB (charging & data), optional RS485, infrared

Data Storage

100,000 data records standard (custom capacity available)

Protection Rating

IP67

Explosion Proof Rating

Intrinsically Safe: Exia II C T4 Ga / Exia D20 T130°C

 