Share:


ERANNTEX Portable Pump-Suction Infrared Acetylene Detector

Specifications

SKU: ERANNTEX Portable Pump-Suction Infrared Acetylene Detector

Model:BTYQ-MS500-C2H2
The Eranntex BTYQ-MS500-C2H2 Portable Pump-Suction Infrared Acetylene Detector features a built-in pump-suction measurement mechanism and integrated moisture and dust filtration units, ensuring rapid response. It is spray-proof, dust-proof, explosion-proof, and vibration-resistant, and utilizes an intrinsically safe circuit design to effectively resist static and electromagnetic interference. The display interface supports three flexible modes: simultaneous display of five-channel gas concentrations, large-font loop readings for a single channel, or real-time graphs. Each channel supports automatic or manual loop switching, and the display of maximum, minimum, and average values ​​can be customized. The device is compatible with both real-time and timed detection modes

The Eranntex BTYQ-MS500-C2H2 Portable Pump-Suction Infrared Acetylene Detector provides a multi-dimensional alarm system, supporting various alarm modes, including audible and visual, visual, combined audible, visual, and vibration. Alarm types include excessive concentration, battery undervoltage, and system failure, and alarm modes include low limit, high limit, range, and weighted average. The device features a built-in factory reset function, automatic zero-point tracking technology to eliminate the effects of long-term drift, multi-level calibration support, and a mechanism to identify and block concentration calibration errors. An optional ambient temperature and humidity detection module is available, along with RS485 communication interface expansion. Additional functions and communication protocols can be customized, and OEM/ODM services are also available.

Eranntex BTYQ-MS500-C2H2 Portable pump-suction infrared acetylene detector technical parameters

 

Parameter

Specification

Target Gas

C₂H₂ (Acetylene)

Detection Range

0-10000ppm

Resolution

1ppm

Detection Principle

High-precision NDIR infrared

Typical Accuracy

≤±2% F.S. (Higher accuracy customizable)

Linearity

≤±2%

Repeatability

≤±2%

Uncertainty

≤±2%

Response Time (T90)

≤30 seconds

Recovery Time

≤30 seconds

Operating Environment

Temp.: -20℃~+55℃ (typ.), -40℃~+70℃ (max.)<br>Humidity: ≤95% RH (non-condensing)<br>(High-temp. sampling handle optional for extreme conditions)

Temp./Humidity Sensor (Optional)

Temp.: -40℃~+70℃ (Accuracy: 0.5℃)<br>Humidity: 0~100% RH (Accuracy: 3% RH)

Power Supply

3.7VDC, 6000mAh rechargeable polymer battery

Display & Operation

2.5-inch 320*240 color screen, 8-button operation

Sampling Method

Built-in pump (500 ml/min flow rate)

Communication Interfaces

USB (charging & data), optional RS485, infrared

Data Storage

100,000 records (standard, other capacities customizable)

Ingress Protection

IP66

Explosion-proof Rating

Intrinsic safety: ExiaⅡC T4 Ga/ExiaD20 T130℃

Dimensions (H×L×T)

195×77×46 mm

Weight

500g (varies slightly with gas configuration)

 

Eranntex BTYQ-MS500-C2H2 Portable pump-suction infrared acetylene detector display interface

Portable Pump-Suction Infrared Acetylene Detector

All-in-one interface

Portable Pump-Suction Infrared Acetylene Detector

single gas interface

Portable Pump-Suction Infrared Acetylene Detector

curve display interface

(The all-in-one interface is not available for single gas detection)

 

Eranntex BTYQ-MS500-C2H2 Portable pump-suction infrared acetylene detector actual picture

Portable Pump-Suction Infrared Acetylene Detector
Portable Pump-Suction Infrared Acetylene Detector
Portable Pump-Suction Infrared Acetylene Detector
 

Eranntex BTYQ-MS500-C2H2 Portable pump-suction infrared acetylene detector optional accessories: (Optional accessories require additional charges)

Portable Pump-Suction Infrared Acetylene Detector

High humidity filter

Portable Pump-Suction Infrared Acetylene Detector

40cm/120cm metal sampling handle

Portable Pump-Suction Infrared Acetylene Detector

telescopic sampling handle

Portable Pump-Suction Infrared Acetylene Detector

High-temperature sampling handle

(0.3m 400°C/0.7m 800°C/1.2m 1300°C; three sizes available)

List of some detectable gases (please consult sales engineers for gases not listed)

 

Target Gas

Detection Range

Combustible Gas EX

0-100%LEL, 0-100%Vol

Methane CH₄

0-100%LEL, 0-100%Vol, 0-1000ppm, 0-10000ppm

Oxygen O₂

0-30%Vol, 0-100%Vol, 0-5000ppm

Nitrogen N₂

0-100%Vol

Carbon Monoxide CO

0-100ppm, 0-1000ppm, 0-2000ppm, 0-20000ppm, 0-100000ppm

Carbon Dioxide CO₂

0-500ppm, 0-2000ppm, 0-5000ppm, 0-50000ppm, 0-20%Vol, 0-100%Vol

Formaldehyde CH₂O

0-10ppm, 0-100ppm, 0-1000ppm

Ozone O₃

0-1ppm, 0-5ppm, 0-50ppm, 0-100ppm, 0-2000ppm, 0-30000ppm

Hydrogen Sulfide H₂S

0-10ppm, 0-50ppm, 0-100ppm, 0-2000ppm, 0-10000ppm

Sulfur Dioxide SO₂

0-10ppm, 0-20ppm, 0-100ppm, 0-500ppm, 0-2000ppm, 0-10000ppm

Nitric Oxide NO

0-10ppm, 0-100ppm, 0-2000ppm, 0-5000ppm

Nitrogen Dioxide NO₂

0-10ppm, 0-100ppm, 0-2000ppm, 0-5000ppm

Nitrogen Oxides NOx

0-10ppm, 0-100ppm, 0-2000ppm, 0-5000ppm

Chlorine Cl₂

0-10ppm, 0-20ppm, 0-200ppm, 0-2000ppm

Ammonia NH₃

0-10ppm, 0-100ppm, 0-1000ppm, 0-5000ppm, 0-100%LEL

Hydrogen H₂

0-100%LEL, 0-1000ppm, 0-20000ppm, 0-40000ppm, 0-100%Vol

Helium He

0-100%Vol

Argon Ar

0-100%Vol

Xenon Xe

0-100%Vol

Hydrogen Cyanide HCN

0-30ppm, 0-100ppm

Hydrogen Chloride HCl

0-20ppm, 0-200ppm

Phosphine PH₃

0-10ppm, 0-100ppm, 0-1000ppm, 0-4000ppm

Chlorine Dioxide ClO₂

0-1ppm, 0-10ppm, 0-200ppm

Ethylene Oxide ETO

0-100ppm, 0-1000ppm, 0-100%LEL

Phosgene COCl₂

0-1ppm, 0-50ppm

Silane SiH₄

0-1ppm, 0-50ppm

Fluorine F₂

0-1ppm, 0-10ppm, 0-50ppm

Hydrogen Fluoride HF

0-10ppm, 0-50ppm

Hydrogen Bromide HBr

0-50ppm

Diborane B₂H₆

0-10ppm

Arsine AsH₃

0-1ppm, 0-10ppm, 0-50ppm

Germane GeH₄

0-2ppm, 0-20ppm

Hydrazine N₂H₄

0-1ppm, 0-300ppm

Tetrahydrothiophene THT

0-100mg/m³

Bromine Br₂

0-10ppm, 0-100ppm, 0-2000ppm

Acetylene C₂H₂

0-100%LEL, 0-100ppm, 0-1000ppm

Ethylene C₂H₄

0-100%LEL, 0-100ppm, 0-2000ppm

Ethanol C₂H₆O

0-100ppm, 0-2000ppm, 0-100%LEL

Methanol CH₄O

0-100ppm, 0-2000ppm

Carbon Disulfide CS₂

0-50ppm, 0-5000ppm

Acrylonitrile C₃H₃N

0-50ppm, 0-2000ppm

Methylamine CH₅N

0-50ppm

Iodine I₂

0-50ppm

Styrene C₈H₈

0-10ppm, 0-100ppm, 0-200ppm, 0-1000ppm, 0-5000ppm

Vinyl Chloride C₂H₃Cl

0-100ppm, 0-1000ppm

Trichloroethylene C₂HCl₃

0-100ppm, 0-1000ppm

Tetrachloroethylene C₂Cl₄

0-100ppm, 0-1000ppm

Nitrous Oxide N₂O

0-100ppm

Nitrogen Trifluoride NF₃

0-100ppm

Hydrogen Peroxide H₂O₂

0-100ppm, 0-1000ppm

Methyl Bromide CH₃Br

0-100ppm, 0-30000ppm, 0-200g/m³

Sulfuryl Fluoride SO₂F₂

0-100ppm, 0-5000ppm, 0-10000ppm

Benzene C₆H₆

0-10ppm, 0-100ppm, 0-1000ppm, 0-10000ppm

Toluene C₇H₈

0-10ppm, 0-100ppm, 0-1000ppm, 0-10000ppm

Xylene C₈H₁₀

0-10ppm, 0-100ppm, 0-1000ppm, 0-10000ppm

VOC

0-10ppm, 0-100ppm, 0-1000ppm, 0-10000ppm

TVOC

0-10ppm, 0-100ppm, 0-1000ppm, 0-10000ppm

Non-Methane Hydrocarbons CxHy

0-10ppm, 0-100ppm, 0-1000ppm, 0-10000ppm

Refrigerants

0-1000ppm, 0-2000ppm, 0-5000ppm

Sulfur Hexafluoride SF₆

0-1000ppm, 0-2000ppm, 0-3000ppm

 

 

Hot Tags: Portable Pump-Suction Infrared Acetylene Detector