Share:


ERANNTEX Fixed Combustible Gas Detector

Specifications

SKU: ERANNTEX Fixed Combustible Gas Detector

Model:GTYQ-MIC-600-Ex, PM2.5, CO2, Ex, CH4, C2H6, C3H8, CxHy, CO, H2S, O2, N2, NH3, CL2, H2, He, Ar, CH2O, O3, NO, NO2, NOX, SO2, ETO, C2H4O, PH3, HCL, HCN, COCL2, CLO2, SiH4, CH3Br, SO2F2, F2, HF, HBr, B2H6, AsH3, GeH4, N2H4, C2H8N2, N2O4
The Eranntex GTYQ-MIC-600-Ex Fixed Combustible Gas Detector provides 24-hour continuous online monitoring of combustible gas concentrations, along with temperature and humidity measurements. It displays concentrations on-site, provides audible and visual alarms for exceeding limits, and enables remote data transmission. It features a 2.5-inch high-definition color screen for real-time concentration display. It utilizes leading-edge electrochemical, infrared, catalytic combustion, thermal conductivity, and PID photoionization gas sensors, along with Swiss high-precision capacitive digital temperature and humidity sensors, tailored to the specific gas being detected. The MIC-600's advanced circuit design and sophisticated core algorithm processing have resulted in multiple software and design patents, resulting in a new generation of industry-leading, multifunctional fixed combustible gas detectors. The MIC-600 can monitor gas concentrations in pipelines, confined spaces, and atmospheric environments, detect gas leaks, and even measure the purity of high-concentration single gases. Its durable explosion-proof housing and fluorocarbon paint finish are suitable for hazardous locations and corrosive environments with strong acids and alkalis. It is abrasion-resistant and will not fade or peel for 10 years.

The Eranntex GTYQ-MIC-600-Ex Fixed combustible gas detector adopts intrinsically safe circuit design and has passed explosion-proof certification. It has secondary lightning protection and anti-static capabilities (exceeding national standards), can withstand high-intensity pulse surge current impacts, and its high-reliability anti-reverse polarity design ensures that any reverse polarity will not damage the instrument. It complies with EMI/EMC standards and has passed national standard testing and CMC metrology certification. The implementation standards include GB15322.1-2003, GB 3836.1-2010, GB 3836.2-2010 and GB 3836.4—2010; simultaneously outputs RS485 (RTU) bus and 4-20mA standard signals, provides three relay outputs and an optional on-site audible and visual alarm. Available frequency outputs include 200-1000Hz, Hart protocol signals, 1-5V output, or wireless transmission (2-5 km/unlimited distance). Supports wired or wireless remote monitoring, and data can be uploaded to a mobile phone or transmitted via a LAN or the Internet to an environmental protection bureau, monitoring center, terminal device, or computer. Real-time concentration monitoring is achieved using free host software or a gas alarm controller.

Eranntex GTYQ-MIC-600-Ex Fixed Combustible Gas Detector Features:

● Compatible with various secondary meters, data acquisition modules, PLCs, and DCS systems, it can directly drive solenoid valves, fans, alarms, and other devices, and can also drive high-power devices via intermediate relays. The optional MIC2000 controller can simultaneously monitor up to 1000 detectors.

● Large-capacity data storage allows recording of real-time concentration values, temperature and humidity, or simply the alarm value and time. The device supports local storage or SD card storage. The standard local storage capacity is 100,000 records. Please specify when ordering for a larger capacity. SD card storage capacity is customizable. Data export and analysis are performed using free host software. Data can be viewed and deleted locally, and can be configured to automatically overwrite or not overwrite data when capacity is insufficient, as well as automatically stop recording.

●The standard infrared remote control enables operations in hazardous locations without opening the device, such as modifying alarm points, calibrating concentrations, zeroing, silencing, restoring factory settings, entering menus, viewing records, and outputting 4mA and 20mA currents (required for calibrating other data acquisition devices).

● Available in Chinese and English, the default interface is Chinese. Gas concentration units can be freely switched. Molecular weight input is not required for conventional gases, but it is automatically calculated and switched for special gases upon molecular weight input. Available units include PPM, mg/m³, Vol%, LEL%, PPHM, ppb, and mg/L.

● A 2.5-inch high-definition color screen (LCM) displays real-time concentration, time, temperature, humidity, storage status, and other information. It can simultaneously monitor 4-6 gas concentrations, along with temperature and humidity. The menu interface uses high-definition, realistic icons to display menu functions, and provides simple Chinese or English operation instructions.

● Three display modes are available: simultaneous display of multiple gas concentrations, large-font, looped display of single-channel gas concentrations, and real-time curves. Channels can be automatically or manually cycled. Display of maximum and minimum values, gas names, and historical curves can be configured.

● Automatic zero tracking prevents drift, temperature compensation, and multi-level calibration ensure compliance with national standards and local and provincial metrology bureau standards.

● Data recovery and automatic detection and prevention of concentration calibration errors prevent problems caused by improper operation.

● Features include calibration logs, maintenance logs, troubleshooting solutions, sensor life expiration reminders, and reminders for the next concentration calibration.

Eranntex GTYQ-MIC-600-Ex Fixed Combustible Gas Detector Specifications:

Detected Gases: Combustible Gases (Ex). Optional: Simultaneous detection of up to 4-6 gas concentrations and temperature and humidity.

Detection Principle: Catalytic combustion, with optional infrared, thermal conductivity, and PID photoionization depending on gas type, range, site environment, and user needs.

Sensor Lifespan: Catalytic combustion (3 years), infrared (5-10 years), electrochemical (2-3 years), oxygen (2 or 6 years optional), thermal conductivity (5 years), PID (2 years).

Detection Range: 0-1000, 5000, 10000, 50000 ppm, 100% LEL, 5%, 50%, 100% Volt. Other ranges available on request.

Resolution: 0.01 ppm or 0.001 ppm (0-10 ppm); 0.01 ppm (0-100 ppm), 0.1ppm (0-1000 ppm), 1ppm (0-1000 ppm and above), 0.1%LEL (0-100%LEL), 0.01%Vol or 0.001%Vol (0-99.999%Vol)

Temperature detection: -40°C to +120°C (optional), Humidity detection: 0-100%RH (optional), Resolution: 0.1°C for temperature, 1%RH for humidity

Accuracy: ≤±2%F.S (2% within full scale), 0.5°C for temperature, 3%RH for humidity; higher accuracy available on request.

Detection methods: Fixed installation, online detection, diffusion measurement, in-line (M45 x 1.5 external thread), flow-through, and pump-type options available.

Mounting methods: In-line and wall-mount. The operating pressure for pipeline models is atmospheric pressure ±30%. Pressure reduction is required if the pressure exceeds this range.

Response Time: T90 ≤ 20 seconds

Recovery Time: ≤ 30 seconds

Output Signal: RS485 bus (RTU), three-wire (four-wire) 4-20mA, optional 0-20mA, 1-5V, 0-5V, 0-10V, wireless transmission

Alarm Method: Local audible and visual alarm (optional), default 1-way, optional 3-way passive contact (dry contact) output, three-level alarm, configurable alarm points

Operating Environment: -40°C to +70°C

Sample Gas Temperature: -40°C to +70°C (typical), optional: -40°C to +400°C, -40°C to +800°C (maximum 1300°C)

Relative Humidity: ≤10-95% RH (typical), non-condensing, optional: 10-99% RH For use in high-temperature and high-humidity environments. Please specify when ordering. Requires a pre-treatment system.

Operating Voltage: 12-30V DC (DC; standard power supply for a single device is 24V, 1A or greater DC switching power supply).

Power Supply Reference: A 24V, 2.1A switching power supply can operate 40 toxic gas detectors or 15 flammable and infrared gas detectors.

Explosion-Proof: Flameproof Exd II CT6.

Connecting Cable: 4-20mA, three-core shielded cable; RS485, four-core. For distances exceeding 1000m, single wire diameter ≥ 1.5mm; shield connected to ground.

Electrical Connector: 3/4" NPT, optional M20x1.5 female thread, 1/2" NPT available.

Ingress Protection: IP66. Protected against water splashes and short-term rain exposure. For extended exposure, a rain cover or housing without a display must be selected, or specify when ordering.

Dimensions: 210×170×85mm.

Weight: 150g Weight: 1.8 kg

Optional Accessories: Wall mounting bracket, pipe mounting bracket (four-way and six-way pipes), DN50 flange pipe mounting or stainless steel threaded weld socket (pipe size must be specified, e.g., DN50, DN15, etc.), normal temperature and high humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature and high dust pretreatment system, pressure reducing valve, flow meter, temperature and humidity measurement, large-capacity SD memory card, rain cover, 24VDC or 220AC sampling pump (sampling distance 10 meters), vacuum pump (sampling distance greater than 40 meters), 24V switching power supply.

Required accessories for computer monitoring: Free host computer software, RS485/RS232 converter, USB/RS232 conversion cable for laptops without RS232 ports, TCP/IP converter for network transmission.

Applications: Petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment, and other applications requiring fixed installation and online gas concentration monitoring.

Hot Tags: Fixed Combustible Gas Detector


 Inquiry - ERANNTEX Fixed Combustible Gas Detector