ERANNTEX TH-2000-OU Odor Monitoring Online System

Specifications

SKU: ERANNTEX TH-2000-OU Odor Monitoring Online System

Model:TH-2000-OU, CxHy, CO, H2S, O2, NH3, CL2, H2, CH2O, O3, NO, NO2, NOX, SO2, ETO, PH3, HCL, HCN, COCL2, CLO2, SiH4, CH3Br, F2, HF, HBr, B2H6, AsH3, GeH4, N2H4, C2H6S, C2H4O2, MA, EA, C2H6O, C2H6S2, SiH2Cl2
The Eranntex TH-2000-OU Odor monitoring online system, commonly known as an odor electronic nose, is independently developed and manufactured based on China's current odor detection standards, "Odor Pollutant Emission Standard GB14554-93" and "Three-Point Comparison Odor Bag Method GB/T 14675-93." This system correlates test results with human olfaction, utilizing patented technology and independent algorithms.

The Eranntex TH-2000-OU Odor monitoring online system consists of a power supply unit, a sampling unit, a sample gas processing unit, a sensor detection unit, a data processing unit, a display unit, and a transmission unit.

Features of the Eranntex TH-2000-OUOdor Monitoring Online System

★Combine any odor gas parameters to monitor odor emission concentrations and patterns at the monitoring site in real time.You can select from 1 to 9 indicators, including ammonia, trimethylamine, hydrogen sulfide, methyl mercaptan, dimethyl disulfide, carbon disulfide, styrene, and odor OU values. It also supports monitoring of other gases and meteorological parameters such as PM2.5, PM10, temperature and humidity, wind speed and direction, atmospheric pressure, noise, and illumination.

★ A rich human-machine interface perfectly displays all monitoring data.The industrial-grade, high-definition 7-inch touch screen displays real-time monitoring and allows you to query historical data for any time period.

★Strong system compatibility and powerful functionality Compatible with electrochemical, MOS, PID, catalytic combustion, infrared, and semiconductor sensors.

★ Intelligent plug-in sensor technology: plug and play, automatic expansion recognition

★ Sensitive response, accurate measurement

★ Internal and external diffusion sampling, optional sampling pump, multiple filter protection devices, and dedicated sensor chamber

★ Intelligent calibration and multiple data correction modes ensure data stability

★ Automatic zero-point tracking, automatic calibration, intelligent data compensation, intelligent K-value algorithm, and calibration with a standard gas target point.

★ Multiple signal output options for diverse transmission options.Supports wireless or wired transmission methods such as RS485, 4G/5G, 433M, NB-IOT, and LoRa, with resumable transmission and compatibility with MODBUS and HJ/T-212 protocols.

★ Large-capacity data storage: 16GB

The Eranntex TH-2000-OU Odor monitoring online system

Testing Item

Gas Category

Chemical Formula

Range

Resolution

Common Gases

 

 

 

 

 

Odor

OU

0-2000 (dimensionless)

1

 

Ammonia

NH₃

0-10 mg/m³

0.01 mg/m³

 

Hydrogen Sulfide

H₂S

0-10 mg/m³

0.01 mg/m³

 

Volatile Organic Compounds

VOC

0-10 mg/m³

0.01 mg/m³

 

Trimethylamine

C₃H₉N

0-10 mg/m³

0.001 mg/m³

 

Methanethiol

CH₄S

0-10 mg/m³

0.001 mg/m³

 

Dimethyl Sulfide

C₂H₆S

0-10 mg/m³

0.001 mg/m³

 

Dimethyl Disulfide

C₂H₆S₂

0-10 mg/m³

0.001 mg/m³

 

Carbon Disulfide

CS₂

0-10 mg/m³

0.001 mg/m³

 

Styrene

C₈H₈

0-10 mg/m³

0.001 mg/m³

Note: Other gases/ranges available upon request

 

 

 

 

 

Meteorological Parameters

 

 

 

 

 

Temperature

T

-40°C to +70°C

0.1°C

 

Humidity

H

0-100% RH

1% RH

 

Fine Particulate Matter

PM2.5

0-1000 μg/m³

1 μg/m³

 

Coarse Particulate Matter

PM10

0-1000 μg/m³

1 μg/m³

Note: Additional parameters available upon request (e.g., wind speed, wind direction, illuminance, noise)

 

 

 

 

Product Configuration List

TH-2000-OU Online Odor Monitoring System (220V AC power supply)

1 set

1

Detection unit

Digital sensor module (10 detection factors)

1

each

2

Power management system

Supplies power to each unit

1

each

3

Wireless transmission module

Transmits data to the network platform via the DTU (212 protocol)

1

each

4

Fan or brushless pump

Maintains air exchange within the chassis (or pumped air).

1

set

5

Stainless steel chassis

304 stainless steel, 60*40*20 cm. Features rainproof, dustproof, fan-heat resistant, UV-resistant (aging-resistant), rust-resistant, acid- and alkali-resistant, and electromagnetic interference (lightning-resistant). The chassis features a highly flexible, modular, quick-release structure for quick installation and maintenance. Real-time display of monitoring data and function operation.

1

each

6

7-inch LCD color screen

1.2m or 1.5m.

1

each

7

Mounting stand

Equipped with two clamps and screws for easy installation.

1

each

8

Instruction manual

Base dimensions: 30*30cm. Four 10mm expansion screws are recommended for mounting.

1

this

9

Antenna

Instructions

1

support

10

Chassis key

DTU wireless transmission antenna

1

each

11

Particle detection

For use with the chassis

1

each

12

Five meteorological parameters

Optional

1

each

 TH-2000-OU Odor Monitoring Online System

 

The Eranntex TH-2000-OU Odor monitoring online system Applications:

The Eranntex TH-2000-OU Odor monitoring online system is primarily used by government environmental monitoring departments and businesses with air pollution, including science and technology parks, chemical parks, wastewater treatment plants, pharmaceutical factories, breweries, energy and power companies, textile mills, urban and rural residential areas, research institutes, and universities.

The Eranntex TH-2000-OU Odor monitoring online system Physical pictures & installation examples:

The product's dimensions are as follows: the main unit measures 600 x 400 x 220 mm, with mounting posts available in 1.2- and 1.5-meter lengths. It comes with two clamps and screws for easy installation. The base measures 300 x 300 mm and is recommended to be secured with four 10 mm expansion screws.

TH-2000-OU Odor Monitoring Online SystemTH-2000-OU Odor Monitoring Online SystemTH-2000-OU Odor Monitoring Online System

 

Hot Tags: TH-2000-OUOdor Monitoring Online System


 Inquiry - ERANNTEX TH-2000-OU Odor Monitoring Online System