ERANTTEX Simple Gas Detection System (including gtyq-MIC-500S Detector)
Brand: ERANNTEX
Specifications
SKU: ERANTTEX Simple Gas Detection System (including gtyq-MIC-500S Detector)
The Eranntex Simple Gas Detection System (including gtyq-MIC-500S Detector) features a professional waterproof design, enabling stable operation in complex environments. Its detection performance combines fast response, reliability, and stability, accurately capturing changes in gas concentrations. The system also offers flexible installation options, allowing the analyzer to be integrated into a chassis or installed externally to accommodate diverse scenarios. When configured with standard sampling components, the effective sampling distance reaches 10 meters; if a high-performance vacuum pump is selected, the system can achieve ultra-long-distance sampling by establishing a negative pressure environment, with the maximum distance exceeding 70 meters, greatly expanding the monitoring coverage.
The Eranntex TH-1000B Simple gas detection system (including MIC-500S detector) pre-treatment product configuration:
|
TH-1000B |
Pretreatment Configuration |
|
|
Features: With viewing window Applicable conditions: Normal temperature Low moisture Low dust |
201 stainless steel chassis (with window) Non-explosion-proof chassis, custom explosion-proof chassis available |
|
|
MIC-500S gas detector |
||
|
Glass condensation filter |
||
|
Solenoid drain valve |
||
|
Brushless DC pump |
||
|
Relay expansion board |
||
|
Power management system |
||
|
Flow-through connector |
||
|
Connecting hose |
||
|
Dimensions (600 x 400 x 170 mm) |
The Eranntex TH-1000B Simple gas detection system (including MIC-500S detector) pre-treatment technical parameters:
|
Detected Gas |
Toxic gases, oxygen, carbon dioxide, flammable and explosive gases, TVOC, etc. Please refer to the quotation parameters for details. |
||||
|
Detection Range |
0~1、10、100、1000、5000、50000ppm(mg/m3);0~100%LEL;0~200mg/L;0~20%、50%、100%VOL; Other ranges are available. Please refer to the price list for details. |
||||
|
Resolution |
0.001ppm、0.01ppm、0.1ppm、1ppm;0.1%LEL;0.1mg/L;0.01%VOL,0.001%VOL; Other resolutions can be customized. Please refer to the price list for details. |
||||
|
Detection Principle |
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, UV absorption, laser TDLAS, etc., depending on gas type, range, site environment, and user needs. For specific information, please refer to the quotation parameters. |
||||
|
Typical Accuracy |
≤±3%F.S (Higher accuracy can be customized according to sensor performance) |
||||
|
Linearity |
≤±2% |
Repeatability |
≤±2% |
Uncertainty |
≤±2% |
|
Response Time |
T90≤30s |
Recovery time |
≤30s |
||
|
Processed Sample Gas |
Suitable for locations with low temperatures, low moisture content, and minimal dust. (Excessively high humidity and heavy dust may require additional pretreatment.) |
||||
|
Processed Sample Gas |
Constant temperature: 25°C (optional). Adjustable temperature after treatment. Constant humidity: 70% RH (optional). Adjustable humidity after treatment. |
||||
|
Operating Mode |
Fixed continuous operation, pump suction measurement (positive pressure, negative pressure, vacuum environment can be used) |
||||
|
Operating Voltage |
220VAC,50HZ |
||||
|
Operating Environment |
Operating temperature: -40°C to +70°C (typical), relative humidity ≤99%RH, pressure: 0.1MPA +/-20%, Sampling temperature: -40°C to +70°C (standard) |
||||
|
Sampling Distance |
The standard sampling distance is 10 meters. The sampling distance can be greater than 70 meters when equipped with a high-power vacuum pump. If the pressure of the gas being measured is relatively high, the sampling distance should be larger accordingly. |
||||
|
Display Mode |
On-site 1.7-inch high-definition color screen display, |
||||
|
Signal Output |
① Three-wire (four-wire) 4-20mA output, compatible with various control systems such as alarm controllers, PLCs, and DCS systems; ② RS485 (RTU) bus interface, standard Modbus protocol; ③ Two relay outputs (one standard, one optional) for high and low-range alarms, passive contacts (dry contacts) Optional options: 0-20mA, 1-5V, 0-5V, 0-10V, wireless transmission, network transmission, and SMS alarms |
||||
|
Alarm Mode |
Default 1-way, optional 2-way passive contact (dry node) output, alarm point can be set; on-site sound and light alarm (optional) |
||||
|
Protection Level |
IP65 Waterproof, suitable for outdoor use |
||||
|
Electrical Interface |
3/4NPT Adapter internal thread (optional M20*1.5 internal thread, 1/2NPT, G3/4, G1/2 adapter internal thread) |
||||
|
Box Material |
201Stainless steel |
||||
|
Dimensions |
Length*Width*Height:600*400*170mm |
||||
|
Standard Accessories |
Pre-processing chassis, instruction manual, certificate of conformity, warranty card, infrared remote control, packaging carton |
||||
|
Manufacturer's Certificate |
AAA Corporate Credit Certificate, High-Tech Enterprise Certificate, ISO45001 Occupational Health and Safety Management System Certification, ISO9001 Quality Management System Certification, and IS014001 Environmental Management System Certification |
||||
The Eranntex TH-1000B Simple gas detection system (including MIC-500S detector) is shown in the field application.


Inquiry - ERANTTEX Simple Gas Detection System (including gtyq-MIC-500S Detector)