Linshang LS137 UV Energy Meter FAQ – Before You Buy Malaysia
Linshang LS137 UV Energy Meter FAQ – Before You Buy Malaysia
The Linshang LS137 UV Energy Meter is designed for industrial UV LED curing applications.
However, before purchasing a UV energy meter, users should confirm more than just the model and price.
What wavelength does your machine use?
Is it UV LED or a traditional mercury lamp?
Do you need UV intensity only, or accumulated UV energy as well?
Can the meter handle the expected irradiance?
Below are common questions Malaysian industrial users should consider before selecting the Linshang LS137.
1. What Is the Linshang LS137?
The Linshang LS137 is a UV energy meter designed for measuring UV LED curing sources.
It can provide measurements including:
UV Energy
UV Irradiance
Peak UV Irradiance
Measurement Duration
Temperature
Maximum Temperature
This makes it useful for industrial UV curing process measurement rather than simply checking whether a UV lamp is ON.
2. What Is the LS137 Mainly Used For?
Typical applications can include:
UV LED printing
Digital UV printing
Label printing
Packaging
UV coating
UV adhesive curing
Electronics manufacturing
PCB production
Optical assembly
Automated UV curing
It can be used for process setup, QA/QC, troubleshooting and preventive maintenance.
3. Is LS137 Designed for UV LED?
Yes.
The LS137 is designed for UV LED curing sources.
This is an important point because UV LED and traditional mercury UV lamps have different spectral characteristics.
Do not select a UV energy meter based only on the word “UV.”
4. What Is the Spectral Response of LS137?
The LS137 has a spectral response of approximately:
340–420 nm
This covers the wavelength region used by many industrial UV LED curing systems.
5. What Wavelength Is LS137 Calibrated With?
The LS137 is calibrated using a:
395 nm UV LED source
Therefore, it is particularly relevant to 395 nm UV LED curing applications.
6. Can LS137 Be Used for 395 nm UV LED?
395 nm is one of the most relevant applications for the LS137.
This wavelength is commonly encountered in industrial applications such as:
UV printing
Packaging
Label printing
UV coating
Industrial curing
If your machine uses a 395 nm UV LED source, the LS137 is a strong model to consider.
7. Can LS137 Be Used for 365 nm?
365 nm falls within the stated 340–420 nm spectral response range of the LS137.
However, wavelength coverage alone should not be the only selection criterion.
Users should also consider:
Calibration characteristics
Expected irradiance
Required measurement accuracy
Actual process requirements
For important applications, provide the source specifications before ordering.
8. What About 385 nm and 405 nm?
385 nm and 405 nm are also within the stated spectral response range.
Again, the complete application should be evaluated.
Send MTM Precision:
UV wavelength
UV source model
Expected intensity
Application
before selecting the instrument.
9. What Is the Maximum UV Irradiance Range?
The LS137 supports UV irradiance measurement up to:
40,000 mW/cm²
This high measurement capability makes it relevant to many high-intensity industrial UV LED curing systems within its specified operating conditions.
10. Does LS137 Measure UV Energy?
Yes.
This is one of its key functions.
UV energy represents the accumulated UV exposure during the measurement period.
It is particularly useful for curing applications because product exposure depends on both UV output and time.
11. What Is the Difference Between UV Irradiance and UV Energy?
A simple explanation is:
UV Irradiance = How strong is the UV?
UV Energy = How much UV exposure was accumulated?
For conveyor curing systems, both can be important.
12. Why Isn't UV Intensity Alone Always Enough?
Consider a conveyor line.
The UV source produces strong irradiance.
However, production speed is increased significantly.
The product now spends less time under the UV source.
Peak intensity may remain strong while accumulated UV energy decreases.
Therefore, intensity alone may not describe the complete curing cycle.
13. Can LS137 Measure Peak UV Irradiance?
Yes.
Peak UV irradiance is useful when comparing:
New vs old UV LED modules
Different UV power settings
Different machines
Different curing zones
Before and after maintenance
It provides another useful process parameter.
14. Does LS137 Measure Temperature?
Yes.
The LS137 can provide temperature-related information, including maximum temperature during measurement.
This can be useful when working with:
Plastic
Film
Electronics
Adhesives
Heat-sensitive substrates
Temperature requirements depend on the specific process.
15. Can LS137 Be Used on a Conveyor UV Curing Machine?
Conveyor curing is one of the important applications for UV energy measurement.
A conveyor process can be affected by:
Conveyor speed
UV irradiance
Curing-zone length
Working distance
Number of UV modules
The LS137 can help compare accumulated UV exposure under different production conditions, subject to safe and suitable use with the actual machine configuration.
16. Can LS137 Help When Increasing Conveyor Speed?
Yes, this is a useful application.
A manufacturer can measure the UV curing process:
Before increasing speed
and then:
After increasing speed
Compare:
Peak UV irradiance
Accumulated UV energy
Exposure duration
Product quality
This helps determine how the process has changed.
17. Can LS137 Check UV LED Lamp Aging?
It can be used to monitor UV output over time.
The best method is:
Measure New / Known-Good Lamp
→ Establish baseline
→ Measure periodically
→ Compare trend
A gradual reduction in measured performance can then be investigated.
18. Does a Lower Reading Automatically Mean the UV LED Is Old?
No.
A lower reading can have several possible causes, including:
UV LED degradation
Dirty optical surfaces
Cooling problems
Changed UV power
Changed working distance
Different measurement position
The complete system should be checked before replacing the UV LED module.
19. Can LS137 Help with Preventive Maintenance?
Yes.
A factory can use periodic measurements to track UV curing performance.
For example:
Baseline
→ Monthly / Quarterly / Operating-Hour Check
→ Compare
→ Investigate Significant Change
→ Correct
→ Verify
The appropriate frequency depends on production risk and usage.
20. Can LS137 Be Used for QA/QC?
Yes.
QA/QC teams can record UV measurements together with product-quality results.
For example:
UV Energy: Recorded
Peak Irradiance: Recorded
Conveyor Speed: Recorded
Product Test: PASS
This creates a known-good reference for future production.
21. Can LS137 Tell Me the Correct UV Energy for My Ink?
Not by itself.
The correct curing requirement depends on factors such as:
Ink formulation
Photoinitiator
UV wavelength
Ink thickness
Substrate
Production process
Consult the ink or material manufacturer's requirements and validate the process using actual product testing.
The LS137 measures the UV condition; it does not define the curing specification for every material.
22. Can LS137 Tell Me the Correct UV Energy for My Adhesive?
The same principle applies.
The adhesive manufacturer or validated production process should define the required curing conditions.
The LS137 can help measure and reproduce those conditions.
23. Can LS137 Be Used for UV Coating?
Yes, where the UV source and measurement requirements are suitable.
Potential uses include monitoring UV conditions associated with:
Coating hardness
Adhesion
Scratch resistance
Production consistency
UV measurement should be combined with actual coating-quality tests.
24. Can LS137 Be Used for UV Printing?
Yes.
UV LED printing is an important potential application.
The meter can help investigate problems such as:
Tacky ink
Incomplete curing
Changes after increasing printing speed
UV LED aging
Differences between machines
Always confirm the printer's UV source and wavelength.
25. Can LS137 Compare Multiple UV LED Modules?
Yes, where the machine configuration permits appropriate measurement.
For example:
Module A → Measure
Module B → Measure
Module C → Measure
If one module behaves differently from its historical baseline, maintenance can investigate that specific curing zone.
26. Can I Compare Two UV Curing Machines?
Yes, but comparisons should be made carefully.
Record:
UV wavelength
UV power setting
Working distance
Conveyor speed
Measurement position
Two machines displaying the same power percentage do not necessarily produce identical UV exposure.
27. Is LS137 Suitable for Traditional Mercury UV Lamps?
The LS137 is designed for UV LED curing sources.
For a traditional high-pressure mercury UV curing system, consider a meter intended for that source technology, such as the Linshang LS136, depending on the application.
Always identify the source before ordering.
28. LS136 or LS137 – Which One Should I Buy?
A simple starting point is:
Linshang LS137
For:
UV LED curing
Linshang LS136
For:
Traditional high-pressure mercury UV curing
If you are unsure, send the machine specifications to MTM Precision before purchasing.
29. What Information Should I Provide Before Asking for a Quotation?
Provide as much of the following as possible:
UV Source: LED / Mercury
UV Wavelength:
Machine Brand:
Machine Model:
Expected UV Irradiance:
Application:
Conveyor Speed / Exposure Time:
Measurement Requirement:
A photo of the machine specification label or UV source specification can also help with model selection.
30. Why Establish a Baseline Immediately After Buying the Meter?
Do not wait until a curing problem occurs.
The best time to measure is when production quality is good.
Record:
UV wavelength
UV power
Peak irradiance
UV energy
Exposure duration
Working distance
Conveyor speed
Product-quality result
This becomes your reference.
Later, if curing quality changes, you can compare current measurements against the known-good condition.
31. Who Should Consider Buying LS137?
Potential users include:
Printing factories
Packaging manufacturers
Label printers
UV coating companies
Electronics manufacturers
PCB manufacturers
UV adhesive users
Process engineers
QA/QC departments
Maintenance departments
Machine service companies
The LS137 is particularly useful where UV curing is an important production parameter.
32. What Is the Best Way to Choose a UV Energy Meter?
Use this sequence:
Identify UV Source
→ Confirm Wavelength
→ Check Expected Irradiance
→ Define Required Measurements
→ Check Machine Configuration
→ Select UV Meter
This is safer than purchasing a generic UV meter based only on price.
Before You Buy Linshang LS137 in Malaysia
If you are considering the LS137, send MTM Precision your UV curing information first.
We can review:
UV source technology
Wavelength
Machine type
Application
Expected measurement range
This helps reduce the risk of selecting the wrong UV meter.
Looking for Linshang LS137 UV Energy Meter in Malaysia?
MTM Precision supplies industrial testing and measurement instruments for manufacturing, printing, electronics, engineering, maintenance and QA/QC applications in Malaysia.
The Linshang LS137 UV Energy Meter is particularly relevant for industrial UV LED curing measurement, process monitoring and troubleshooting.
Contact us with your application details for model selection and quotation.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
Contact MTM Precision for Linshang LS137 UV Energy Meter price, technical information, model selection and quotation in Malaysia.
13 Aug 2026