How to Check Multiple UV LED Curing Lamps with Linshang LS137 Malaysia
How to Check Multiple UV LED Curing Lamps with Linshang LS137 Malaysia
Many industrial UV LED curing machines do not rely on a single UV source.
A production line may use:
UV Module 1 → UV Module 2 → UV Module 3
or several UV LED curing zones positioned at different stages of the manufacturing process.
This arrangement can provide high production speed and controlled curing performance. However, it also creates an important maintenance question:
What happens if one UV LED module becomes weaker than the others?
The machine may continue operating normally, and all UV modules may still appear to be ON.
Yet the total UV exposure delivered to the product can change.
The Linshang LS137 UV Energy Meter can help production and maintenance teams measure UV irradiance and accumulated UV energy, making it easier to compare different UV LED curing zones and monitor their performance over time.
Why Do Industrial Machines Use Multiple UV LED Modules?
Multiple UV LED sources may be used to:
Increase total UV exposure
Increase production speed
Cure larger surfaces
Provide multiple curing stages
Improve process control
Support high-speed printing
Cure complex products
Provide different exposure zones
These configurations are common in applications such as:
UV printing
Packaging
Label printing
UV coating
Electronics manufacturing
Adhesive curing
Automated manufacturing
The exact configuration depends on the machine design.
The Problem: One Module Can Change Without Complete Machine Failure
Imagine a production line with three UV LED modules.
Originally:
Module A → Normal
Module B → Normal
Module C → Normal
After extended operation:
Module A → Normal
Module B → Reduced Output
Module C → Normal
The machine may still run.
All three modules may still illuminate.
But the total UV curing condition may no longer be identical to the original validated process.
This can lead to difficult-to-diagnose quality problems.
Why Visual Inspection Is Not Enough
An operator may look at all three UV modules and report:
“All UV lamps are working.”
That confirms only that the sources appear to be operating.
It does not tell you whether:
Module A and Module B have equal output
One module has deteriorated
One optical window is contaminated
Total UV energy has changed
One curing zone is operating differently
For this, quantitative UV measurement is more useful.
What Can Linshang LS137 Measure?
The Linshang LS137 can measure:
UV Energy
UV Irradiance
Peak UV Irradiance
Measurement Duration
Temperature
Maximum Temperature
These parameters can help engineers compare different UV curing zones.
Designed for UV LED Curing
The LS137 is designed for UV LED sources.
Its spectral response is approximately:
340–420 nm
and it is calibrated using a:
395 nm UV LED source
Common industrial UV LED wavelengths can include:
365 nm
385 nm
395 nm
405 nm
Always confirm the actual wavelength of the equipment before selecting a UV measurement instrument.
How to Compare Multiple UV LED Modules
Where the equipment configuration and operating procedure allow individual module testing, a structured comparison can be performed.
For example:
UV Module A
Record:
Power setting
Peak UV irradiance
UV energy
Measurement position
UV Module B
Repeat under comparable conditions.
UV Module C
Repeat again.
The results can then be compared.
The measurement procedure should be kept as consistent as practical.
Example of a Three-Module System
Suppose a production line originally records comparable performance across three UV modules.
Six months later, another inspection is performed.
The results show:
Module A → Similar to baseline
Module B → Significantly lower
Module C → Similar to baseline
This does not automatically prove that Module B must be replaced.
But it tells the maintenance team exactly where to investigate first.
What Should Be Checked If One Module Reads Lower?
Possible causes include:
UV LED degradation
Optical contamination
Different power setting
Cooling problem
Electrical issue
Driver problem
Different measurement geometry
The maintenance team can investigate the affected zone rather than treating the entire curing system as one unit.
Check Optical Cleanliness
Suppose Module B measures lower than Modules A and C.
Before replacing it, check the relevant optical components according to the equipment manufacturer's maintenance procedure.
If contamination is present:
Measure → Clean → Measure Again
If output returns closer to its historical baseline, the problem may have been contamination rather than UV LED deterioration.
Check the Power Setting
Some machines allow individual UV modules to operate at different power levels.
For example:
Module A = 80%
Module B = 60%
Module C = 80%
A lower measurement from Module B may therefore be completely expected.
Always record machine settings when comparing modules.
Check Cooling Performance
Individual UV LED modules may have separate:
Fans
Cooling channels
Heat sinks
Thermal controls
A cooling issue affecting one module may not affect the others.
If one curing zone behaves differently, its cooling system should also be investigated.
Compare Modules Under Similar Geometry
Distance matters.
If Module A is measured at one distance and Module B at another, the readings may not be directly comparable.
For meaningful comparison, keep relevant conditions as consistent as practical, including:
Working distance
Measurement orientation
UV power
Measurement position
This helps distinguish actual lamp differences from setup differences.
Measure the Complete Curing Path
Individual-module comparison is useful for troubleshooting.
However, the finished product may pass through all modules.
Therefore, manufacturers should also consider the total accumulated UV exposure through the actual curing process.
For example:
Module A + Module B + Module C = Total Curing Process
The final product-quality requirement depends on the complete process, not merely one module in isolation.
Conveyor Speed Still Matters
Suppose all three UV LED modules are operating normally.
Production increases conveyor speed.
The product now passes through:
Module A → Module B → Module C
more quickly.
Even though each module remains healthy, total exposure time can decrease.
Therefore, accumulated UV energy through the entire line may also decrease.
Module performance and conveyor speed should both be considered.
Example: High-Speed UV Printing
A printing machine uses several UV LED modules to support high-speed production.
Operators notice that ink curing has become inconsistent.
Instead of increasing every lamp to maximum power, maintenance compares the individual curing zones.
If one zone produces a lower UV reading than its historical baseline, troubleshooting can focus on that specific module.
This can reduce unnecessary adjustments to the rest of the machine.
Example: UV Coating Line
A coating line uses multiple UV LED stages.
The first stage begins the curing reaction, while later stages provide additional exposure.
If one stage loses output, the coating may still appear cured but fail:
Hardness testing
Scratch testing
Adhesion testing
Comparing individual zones and total UV exposure can provide valuable process information.
Example: Electronics Production
An automated electronics line uses several UV exposure stations.
One production station begins showing higher rejection than another.
If the products and materials are identical, UV measurements can be compared between stations.
This can help determine whether the difference originates from the curing equipment.
Comparing Two Identical Production Lines
The same method can be applied across machines.
Suppose a factory has:
Line 1
and
Line 2
Both use nominally identical UV LED curing systems.
However, Line 1 consistently produces better curing results.
Compare:
Peak UV irradiance
Accumulated UV energy
Conveyor speed
Working distance
UV power settings
This may reveal differences that are not visible from the machine control panels.
Don't Assume New Modules Are Identical to Old Modules
After replacing one UV LED module, the new module may produce different output from the remaining older modules.
Therefore, after replacement:
Measure the new module.
Compare with the other modules.
Measure the complete curing process.
Verify product quality.
Record the new baseline.
This creates useful maintenance history.
Build a Module Performance Record
For a multi-module system, consider recording data separately.
For example:
UV ZoneBaselineCurrent ConditionModule ARecordedRecordedModule BRecordedRecordedModule CRecordedRecordedComplete ProcessRecordedRecorded
Over time, this makes it easier to identify which zone is changing.
Trend Each UV Module Separately
Instead of recording only:
“UV Machine Checked – OK”
create a trend for each important curing zone.
For example:
Module A: Stable
Module B: Gradual decline
Module C: Stable
This provides much more useful maintenance information.
High-Intensity UV LED Measurement
Industrial UV LED curing equipment can generate high irradiance.
The Linshang LS137 supports UV irradiance measurement up to:
40,000 mW/cm²
This makes it suitable for many high-intensity UV LED curing applications within its specified operating conditions.
What If All Modules Read Lower?
If all UV modules show lower readings than the historical baseline, investigate common factors such as:
Measurement procedure
Machine power settings
Conveyor configuration
System cooling
Electrical supply
Measurement distance
Do not immediately conclude that every UV LED module has deteriorated simultaneously.
What If Only One Module Reads Lower?
Focus first on that particular zone.
Check:
UV LED condition
Optics
Cooling
Driver
Power setting
Mechanical position
Then measure again after corrective action.
What If All UV Measurements Are Normal?
If UV measurements remain consistent with the known-good baseline but curing quality has changed, investigate other process variables.
These can include:
Ink
Coating
Adhesive
Substrate
Material thickness
Surface preparation
Product position
UV measurement helps narrow down the root cause.
LS137 vs LS136
The correct instrument depends on the UV source.
UV LED Multi-Lamp Curing System
Consider:
Linshang LS137
Traditional High-Pressure Mercury UV Curing System
Consider:
Linshang LS136
Always identify the source technology before selecting the meter.
Who Can Benefit from Multi-Zone UV Measurement?
The LS137 can be useful for:
Maintenance Engineers
Process Engineers
Production Engineers
QA/QC Teams
Equipment Engineers
Printing Companies
Coating Manufacturers
Electronics Manufacturers
Machine Builders
It is particularly useful where several UV LED modules contribute to one curing process.
A Better Way to Maintain Multi-Lamp UV Systems
Instead of:
Product Fails → Increase All UV Lamps
consider:
Measure Each Zone → Compare Baseline → Identify Difference → Investigate Specific Module → Correct → Measure Again → Verify Total Process
This provides a more targeted approach to maintenance.
Looking for Linshang LS137 for Multi-Lamp UV LED Curing Systems in Malaysia?
MTM Precision supplies industrial testing and measurement instruments for manufacturing, engineering, maintenance and quality-control applications in Malaysia.
If your UV curing machine uses multiple UV LED modules, provide us with:
UV wavelength
Number of UV modules
Machine brand and model
Application
Conveyor speed
Expected UV intensity
We can assist you in determining whether the Linshang LS137 UV Energy Meter is suitable for checking your multi-zone UV LED curing system.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
Contact MTM Precision for Linshang LS137 UV Energy Meter enquiries, multi-zone UV curing applications, model selection, technical information and quotation in Malaysia.
13 Aug 2026