Why Measure CO2, PM2.5, PM10, Temperature and Humidity Together Malaysia
Why Measure CO2, PM2.5, PM10, Temperature and Humidity Together Malaysia
Indoor air quality cannot always be understood by looking at only one measurement.
A room may have low particulate matter but elevated CO₂. Another room may have acceptable CO₂ while PM2.5 is elevated due to outdoor pollution, haze, traffic or nearby construction.
Temperature and humidity add further information about the indoor environment.
This is why professional indoor air quality investigations often benefit from looking at multiple parameters together.
The TENMARS TM-380 Multi IAQ Monitor combines five useful measurements in one portable instrument:
CO₂
PM2.5
PM10
Temperature
Relative humidity
For HVAC contractors, facility managers and building maintenance teams in Malaysia, this combination can provide a more complete picture of indoor environmental conditions.
CO₂: Investigating Ventilation in Occupied Spaces
CO₂ is particularly useful when investigating ventilation in occupied rooms.
People continuously generate carbon dioxide through respiration.
As occupancy increases, CO₂ concentrations can rise if ventilation is insufficient relative to the number of people in the room.
Typical areas where CO₂ monitoring can be useful include:
Offices
Meeting rooms
Classrooms
Training rooms
Conference rooms
Commercial buildings
Enclosed workplaces
The TENMARS TM-380 uses an NDIR sensor for CO₂ measurement.
PM2.5: Monitoring Fine Particulate Matter
CO₂ does not tell you how much particulate pollution is present.
For this, a particulate measurement is required.
PM2.5 is particularly relevant when investigating:
Malaysia haze
Outdoor pollution entering buildings
Traffic-related particles
Air purifier performance
Building filtration
General indoor particulate conditions
The TM-380 uses a laser particulate matter sensor to measure PM2.5.
PM10: Additional Information About Particulate Conditions
PM10 represents a larger particle fraction than PM2.5.
It can be useful when investigating environments affected by:
Dust
Construction
Renovation
Cleaning activities
Outdoor particle infiltration
By measuring both PM2.5 and PM10, users obtain additional information about particulate conditions instead of relying on only one particle measurement.
Temperature: Comfort Is Only One Part of IAQ
Temperature is one of the first things occupants notice.
A room that is too warm or too cold may generate complaints immediately.
However, comfortable temperature does not automatically mean good indoor air quality.
For example:
Temperature comfortable + CO₂ elevated
The air-conditioning may be cooling the room effectively, while ventilation still requires investigation.
This is particularly important in air-conditioned buildings.
Relative Humidity: Adding Environmental Context
Relative humidity provides another useful measurement when investigating indoor environmental conditions.
Together with temperature, it helps facility teams understand the thermal and moisture conditions in the room.
When humidity is measured alongside CO₂ and particulate matter, users gain a broader environmental picture than they would from a simple temperature meter.
Why One Parameter Can Be Misleading
Consider an air-conditioned meeting room.
The temperature is comfortable.
If you measure only temperature, you might conclude that everything is satisfactory.
But the room contains 12 people and the doors remain closed.
CO₂ may gradually increase.
At the same time, PM2.5 could be low because an air purifier is operating.
The complete situation might therefore look like:
Temperature: Comfortable
PM2.5: Low
CO₂: Elevated
A temperature-only or PM2.5-only instrument would not show the ventilation-related information.
Scenario 1: Low PM2.5 but High CO₂
This situation may occur in a well-filtered but heavily occupied enclosed room.
For example:
Windows closed
Air purifier operating
Several occupants
Limited fresh-air exchange
Particulate conditions may appear favourable while CO₂ increases.
This is why low PM2.5 should not automatically be interpreted as good overall indoor air quality.
Scenario 2: Low CO₂ but High PM2.5
Now consider a room with good air exchange but significant outdoor particulate pollution.
Outdoor air may introduce particles through:
Ventilation
Open windows
Doors
Building leakage
CO₂ may remain relatively low while PM2.5 is elevated.
A CO₂-only meter would not detect this particulate issue.
Scenario 3: High PM10 During Construction
A commercial building may have acceptable CO₂ and PM2.5 conditions but experience increased dust because of nearby renovation or construction.
PM10 monitoring provides another piece of information for investigating the source and distribution of airborne particles.
Scenario 4: Haze Season in Malaysia
Haze creates an especially useful example of why multiple measurements matter.
When outdoor particulate pollution increases, building occupants may close windows and doors.
This may help reduce outdoor particle entry.
However, in an occupied room, reduced ventilation may contribute to increasing CO₂.
The facility team therefore needs to consider two different objectives:
Reduce particulate infiltration
and
Maintain appropriate ventilation
Monitoring PM2.5 together with CO₂ can help provide measurement data for this investigation.
Scenario 5: Testing an Air Purifier
Suppose a company installs an air purifier in a meeting room.
After operation, PM2.5 falls significantly.
This indicates that particulate conditions have changed.
However, most portable air purifiers do not provide outdoor-air ventilation.
Therefore, a reduction in PM2.5 does not necessarily mean that CO₂ will also decrease.
By monitoring both parameters, users can distinguish between particle removal and ventilation.
Scenario 6: Comparing Different Rooms
A portable multi-parameter meter can also be used to compare different building zones.
For example:
Reception → Open Office → Meeting Room → Training Room → Warehouse
Each area may have different:
Occupancy
Ventilation
Particle sources
Temperature
Humidity
One meter capable of measuring several parameters makes these comparisons easier.
A Useful IAQ Measurement Matrix
When interpreting indoor conditions, consider the parameters together.
Low CO₂ + Low PM2.5
Ventilation and particulate conditions may appear relatively favourable at that time and location.
High CO₂ + Low PM2.5
Investigate ventilation relative to occupancy.
Low CO₂ + High PM2.5
Investigate particulate sources, outdoor air, filtration and building entry points.
High CO₂ + High PM2.5
Both ventilation and particulate conditions may require investigation.
Temperature and humidity can then provide additional environmental context.
Why This Matters for HVAC Contractors
HVAC troubleshooting often starts with a complaint such as:
“The room feels stuffy.”
“The air doesn't feel good.”
“This meeting room is uncomfortable.”
These complaints do not identify the cause.
A multi-parameter instrument allows the technician to collect more information before deciding what system or condition needs further investigation.
Instead of checking only temperature, the technician can examine:
CO₂ + PM2.5 + PM10 + Temperature + Humidity
Why This Matters for Facility Managers
Facility managers are responsible for many different indoor environments.
One day the issue may involve a meeting room with increasing CO₂.
Another day it may involve haze-related PM2.5.
Later, there may be dust from renovation work.
A multi-parameter IAQ monitor provides greater flexibility for these different situations.
Why This Matters for Schools
Classrooms can experience rapid changes in CO₂ because occupancy can be high relative to room size.
During haze periods, schools may also need to consider particulate pollution.
Measuring both parameters can provide useful information about the actual classroom environment.
Why This Matters for Commercial Buildings
Commercial buildings contain many different zones:
Offices
Lobbies
Meeting rooms
Shops
Corridors
Training rooms
Building entrances
Conditions can vary significantly between these locations.
Portable multi-parameter monitoring allows facility teams to investigate specific problem areas rather than assuming one reading represents the whole building.
Record Changes Over Time
Indoor air quality is dynamic.
A room at 8:00 AM may be very different at 3:00 PM.
Occupancy, HVAC operation, outdoor pollution and human activities all change.
The TENMARS TM-380 supports manual and automatic recording, allowing users to observe changes over time rather than depending only on one spot measurement.
One Instrument for Multiple IAQ Questions
The advantage of measuring several parameters is not simply having more numbers on the screen.
Each measurement answers a different question.
CO₂: What is happening with ventilation relative to occupancy?
PM2.5: What are the fine particulate conditions?
PM10: Are larger airborne particles or dust contributing?
Temperature: What are the thermal conditions?
Humidity: What are the relative moisture conditions?
Looking at these measurements together can support a more systematic indoor air quality investigation.
TENMARS TM-380 Multi IAQ Monitor Malaysia
The TENMARS TM-380 combines:
CO₂ + PM2.5 + PM10 + Temperature + Relative Humidity
with NDIR CO₂ sensing, laser particulate measurement, warning indications and data recording capability.
For Malaysian HVAC contractors, facility managers, schools, commercial buildings and maintenance professionals, it provides a convenient portable solution for investigating several important indoor environmental parameters with one instrument.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
Contact MTM Precision for TENMARS TM-380 Multi IAQ Monitor enquiries in Malaysia.
13 Aug 2026