Indoor Air Quality Monitoring for Schools and Classrooms with TENMARS TM-380 Malaysia

Indoor Air Quality Monitoring for Schools and Classrooms with TENMARS TM-380 Malaysia

 

Classrooms can contain many students in a relatively small enclosed space for long periods of time.

 

In Malaysia, classrooms may also be affected by hot and humid weather, air-conditioning, outdoor traffic pollution, nearby construction and seasonal haze.

 

For this reason, classroom indoor air quality should not be evaluated based only on whether the room feels cool or comfortable.

 

The TENMARS TM-380 Multi IAQ Monitor provides a portable solution for measuring CO₂, PM2.5, PM10, temperature and relative humidity in schools, classrooms, tuition centres and training facilities.

 

Why Monitor Classroom Indoor Air Quality?

 

Classroom environmental conditions can change considerably during a school day.

 

Important factors include:

 

Number of students

 

Classroom size

 

Door and window position

 

Air-conditioning

 

Mechanical ventilation

 

Outdoor air quality

 

Nearby traffic

 

Construction activities

 

Cleaning activities

 

Air purifier operation

 

A classroom with five people may behave very differently from the same classroom with thirty or forty people.

 

This makes actual measurement useful when investigating classroom conditions.

 

CO₂ Can Change with Classroom Occupancy

 

People produce carbon dioxide through respiration.

 

As more students enter an enclosed classroom, CO₂ levels can increase if ventilation does not provide sufficient air exchange.

 

The TENMARS TM-380 uses an NDIR CO₂ sensor, allowing users to monitor how CO₂ conditions change as classroom occupancy changes.

 

For example, measurements could be compared:

 

Before students arrive → During the lesson → During break → After the classroom is empty

 

This provides more information than taking only one measurement.

 

Why CO₂ Monitoring Is Useful

 

CO₂ measurement can be useful as part of a ventilation investigation in occupied spaces.

 

Consider two classrooms in the same building.

 

Classroom A: 15 students

 

Classroom B: 35 students

 

Even if both classrooms use similar air-conditioning systems, their indoor conditions may not be identical.

 

Portable monitoring allows maintenance or facility personnel to investigate individual rooms instead of assuming the entire building has the same conditions.

 

Air-Conditioning Is Not the Same as Ventilation

 

This is an important point for schools and commercial buildings.

 

A room can feel cool without necessarily having sufficient fresh-air exchange.

 

Air-conditioning primarily controls indoor temperature and, depending on the system, humidity.

 

Ventilation involves supplying or exchanging air.

 

Therefore, a cool classroom should not automatically be assumed to have ideal ventilation conditions.

 

CO₂ measurement can provide additional information when investigating this issue.

 

PM2.5 Monitoring During Malaysia Haze

 

During periods of haze or elevated outdoor particulate pollution, schools may reduce outdoor activities and keep students indoors.

 

But moving students indoors creates another question:

 

What is the particulate level inside the classroom?

 

Outdoor API/AQI readings provide information about outdoor conditions, but they do not directly measure the PM2.5 concentration inside a particular classroom.

 

The TENMARS TM-380 measures PM2.5 using a laser particulate matter sensor, allowing measurements to be taken directly inside the room.

 

Outdoor Pollution Can Enter the Classroom

 

Particulate matter may enter through:

 

Open windows

 

Open doors

 

Ventilation systems

 

Building entrances

 

Air leakage

 

Student movement between indoor and outdoor areas

 

Different classrooms may therefore show different readings.

 

For example, a classroom beside a busy road may have different particulate conditions from a classroom located further inside the building.

 

Actual measurements can help identify these differences.

 

PM10 Monitoring for Dust

 

The TM-380 also measures PM10.

 

This can be useful in schools affected by:

 

Nearby construction

 

Renovation work

 

Road dust

 

Cleaning activities

 

Open windows

 

Outdoor dust sources

 

Monitoring both PM2.5 and PM10 provides additional information when investigating particulate conditions.

 

CO₂ and PM2.5 Should Be Considered Together

 

During haze, one possible response is to close windows and doors to reduce outdoor particulate entry.

 

However, a heavily occupied classroom with reduced ventilation may experience increasing CO₂.

 

This creates a practical indoor air quality challenge.

 

Low PM2.5 + High CO₂

 

Particulate control may be effective, but ventilation should be investigated.

 

High PM2.5 + Low CO₂

 

Ventilation may be adequate, while outdoor or indoor particulate sources may require investigation.

 

High PM2.5 + High CO₂

 

Both particulate conditions and ventilation may need attention.

 

This is why measuring multiple parameters can provide more useful information than monitoring PM2.5 alone.

 

Check Air Purifier Performance

 

Some schools may operate portable air purifiers during haze periods.

 

The TENMARS TM-380 can be used for simple comparative measurements.

 

Before

 

Measure PM2.5 and PM10 before operating the purifier.

 

During Operation

 

Allow the purifier to operate and observe how particulate readings change.

 

Different Locations

 

Take readings:

 

Near the purifier

 

At student seating areas

 

At the back of the classroom

 

Near doors

 

Near windows

 

This can help determine whether particulate conditions are similar throughout the room.

 

Temperature and Humidity Matter Too

 

The TENMARS TM-380 also measures:

 

Temperature

 

Relative humidity

 

These parameters provide additional information about classroom environmental conditions.

 

This can be useful when investigating complaints such as:

 

Classroom feels too warm

 

Room feels humid

 

Air-conditioning seems ineffective

 

Conditions vary between classrooms

 

Instead of carrying separate instruments, several parameters can be checked with one portable meter.

 

Suggested Classroom Measurement Locations

 

For a basic classroom IAQ investigation, consider taking measurements at:

 

Classroom entrance

 

Teacher's area

 

Centre of classroom

 

Rear student seating area

 

Near windows

 

Near air-conditioning outlets

 

Near an air purifier

 

Corridor outside the classroom

 

Comparing these locations can help identify variations within the room and between indoor and adjacent areas.

 

Don't Take Only One Reading

 

Indoor air quality changes over time.

 

For example:

 

7:30 AM – Classroom empty.

 

8:00 AM – Students enter.

 

10:00 AM – Classroom occupied for several hours.

 

10:30 AM – Students leave for break.

 

11:00 AM – Classroom occupied again.

 

1:00 PM – School session ends.

 

CO₂, particulate matter, temperature and humidity may change throughout these periods.

 

The TENMARS TM-380 supports manual and automatic recording, making longer-term observation possible.

 

Suitable Educational Applications

 

The TENMARS TM-380 can be considered for:

 

Primary schools

 

Secondary schools

 

Private schools

 

International schools

 

Colleges

 

Universities

 

Tuition centres

 

Training centres

 

Computer rooms

 

Libraries

 

Lecture rooms

 

Laboratories

 

Useful for School Facility Management

 

School maintenance and facility teams can use portable IAQ measurements when investigating:

 

Poor ventilation concerns

 

Haze conditions

 

Dust complaints

 

Air purifier effectiveness

 

HVAC performance

 

Differences between classrooms

 

Indoor environmental complaints

 

Measurements can help determine where further investigation or corrective action may be required.

 

One Meter for Five IAQ Parameters

 

Instead of using separate instruments for different measurements, the TENMARS TM-380 combines:

 

CO₂ + PM2.5 + PM10 + Temperature + Relative Humidity

 

This makes it particularly convenient for walking inspections across multiple classrooms.

 

TENMARS TM-380 for Schools in Malaysia

 

Malaysia's combination of warm weather, widespread air-conditioning, urban traffic, construction activity and periodic haze makes indoor air quality monitoring relevant for many educational facilities.

 

The TENMARS TM-380 provides schools and facility professionals with a portable instrument for checking several important indoor environmental parameters.

 

It can be particularly useful when the objective is not simply to know the outdoor AQI, but to understand what is actually happening inside the classroom.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346

 

Contact MTM Precision for TENMARS TM-380 Multi IAQ Monitor enquiries in Malaysia.


 

13 Aug 2026