CO2, PM2.5 and PM10 Monitoring for Offices Using TENMARS TM-380 Malaysia

CO2, PM2.5 and PM10 Monitoring for Offices Using TENMARS TM-380 Malaysia

 

Modern offices in Malaysia are commonly air-conditioned for many hours every working day.

 

Windows may remain closed, meeting rooms can become crowded, and employees may spend most of their working hours indoors.

 

Under these conditions, indoor air quality should not be judged simply by whether a room feels cool and comfortable.

 

The TENMARS TM-380 Multi IAQ Monitor allows users to measure CO₂, PM2.5, PM10, temperature and relative humidity with one portable instrument, making it useful for office indoor air quality investigations.

 

Why Monitor Indoor Air Quality in an Office?

 

Office air conditions can change according to several factors:

 

Number of occupants

 

Ventilation rate

 

HVAC operation

 

Outdoor air pollution

 

Building filtration

 

Open doors and windows

 

Cleaning activities

 

Renovation or construction nearby

 

Air purifier operation

 

Because these conditions change throughout the day, measurements can provide useful information that cannot be obtained simply by looking at the thermostat.

 

CO₂ Monitoring for Office Ventilation

 

CO₂ is an important parameter when investigating ventilation in occupied spaces.

 

People generate carbon dioxide through respiration.

 

When many employees occupy an enclosed room and outdoor air exchange is insufficient, CO₂ concentrations can increase.

 

This is particularly relevant in:

 

Meeting rooms

 

Conference rooms

 

Training rooms

 

Small offices

 

Enclosed workspaces

 

High-occupancy areas

 

The TENMARS TM-380 uses an NDIR sensor for CO₂ measurement, allowing facility teams to check CO₂ levels at different locations.

 

A Meeting Room Can Be Very Different from an Open Office

 

One common mistake is to take a measurement in one location and assume that it represents the entire office.

 

Consider a typical office:

 

The open working area may have relatively stable conditions.

 

However, a small meeting room containing eight or ten people may experience a much faster increase in CO₂.

 

This is why portable measurements are useful.

 

With the TM-380, technicians can move between areas and compare conditions.

 

For example:

 

Reception → Open Office → Meeting Room → Manager's Room → Training Room

 

This helps identify locations that may require further ventilation investigation.

 

Why Measure PM2.5 in an Office?

 

An air-conditioned office is not automatically protected from particulate pollution.

 

PM2.5 can potentially enter from outside through:

 

Ventilation systems

 

Open doors

 

Open windows

 

Building entrances

 

Air leakage

 

Indoor activities can also influence particulate levels.

 

During periods of haze or poor outdoor air quality in Malaysia, particulate monitoring becomes particularly useful.

 

The TM-380 measures PM2.5 using a laser particulate matter sensor, allowing users to check actual particle concentrations inside the office.

 

Why Measure PM10?

 

PM10 represents a larger particle fraction than PM2.5.

 

Monitoring PM10 can be useful when investigating environments affected by:

 

Dust

 

Nearby construction

 

Renovation

 

Building maintenance

 

Cleaning activities

 

Outdoor particle entry

 

Because the TENMARS TM-380 measures both PM2.5 and PM10, users can obtain a broader view of particulate conditions.

 

CO₂ and PM2.5 Tell You Different Things

 

One of the most useful features of a multi-parameter IAQ monitor is the ability to compare different measurements.

 

For example:

 

High CO₂ + Low PM2.5

 

Particulate conditions may be relatively low, while ventilation in the occupied room may require investigation.

 

Low CO₂ + High PM2.5

 

Ventilation may appear adequate from a CO₂ perspective, but particulate pollution may still be present.

 

High CO₂ + High PM2.5

 

Both ventilation and particulate conditions should be investigated.

 

Low CO₂ + Low PM2.5

 

Conditions may appear relatively favourable at that particular time and measurement location.

 

The key point is simple:

 

Low PM2.5 does not automatically mean good ventilation, and low CO₂ does not automatically mean low particulate pollution.

 

Temperature and Humidity Monitoring

 

Office comfort is also influenced by temperature and relative humidity.

 

The TENMARS TM-380 measures both parameters alongside CO₂ and particulate matter.

 

Facility teams can therefore evaluate several environmental conditions using one instrument rather than taking separate meters from room to room.

 

Example: Checking a Meeting Room

 

A practical office investigation could be performed as follows.

 

Before the Meeting

 

Take baseline readings for:

 

CO₂

 

PM2.5

 

PM10

 

Temperature

 

Relative humidity

 

During the Meeting

 

Observe whether CO₂ changes as occupancy increases.

 

After the Meeting

 

Continue monitoring to see how conditions change after people leave or ventilation is increased.

 

This type of comparison can help facility teams understand how occupancy affects the room.

 

Example: Testing an Air Purifier

 

Suppose an office uses an air purifier during haze season.

 

The TM-380 can be used to compare PM2.5 and PM10 readings:

 

Before purifier operation

 

versus

 

After purifier operation

 

Measurements can also be taken at several locations around the office.

 

This gives users actual particle measurements instead of depending only on the purifier's built-in display.

 

Example: Investigating Employee Complaints

 

Employees may report that a meeting room feels stuffy or uncomfortable.

 

Instead of relying entirely on subjective observations, facility personnel can check several parameters.

 

For example:

 

Is CO₂ increasing when the room is occupied?

 

Is PM2.5 elevated?

 

Is PM10 elevated?

 

What are the temperature and humidity conditions?

 

The measurements do not automatically identify every cause, but they provide useful information for deciding what should be investigated next.

 

Manual and Automatic Recording

 

Office conditions can vary throughout the day.

 

A measurement taken at 8:30 AM may be very different from one taken at 3:00 PM.

 

The TENMARS TM-380 supports manual and automatic recording, which can be useful when users need to observe environmental changes over a longer period.

 

This is especially relevant when investigating:

 

Occupancy patterns

 

Meeting-room conditions

 

HVAC schedules

 

Ventilation changes

 

Air purifier performance

 

Haze-related particle infiltration

 

Who Can Use the TENMARS TM-380?

 

The instrument can be useful for:

 

Facility managers

 

Building managers

 

HVAC contractors

 

Maintenance teams

 

Safety personnel

 

Environmental consultants

 

IAQ service providers

 

Office administrators

 

Commercial property operators

 

Portable IAQ Monitoring for Malaysian Offices

 

A major advantage of a portable IAQ monitor is flexibility.

 

One instrument can be taken from room to room instead of installing a permanent sensor at every location.

 

This makes the TENMARS TM-380 particularly useful for troubleshooting and spot-checking applications.

 

Potential measurement locations include:

 

Reception areas

 

Workstations

 

Meeting rooms

 

Conference rooms

 

Training rooms

 

Pantry areas

 

Building entrances

 

Enclosed offices

 

Air purifier locations

 

Don't Judge Office IAQ by Temperature Alone

 

A room can be cool but still have elevated CO₂.

 

It can also have comfortable humidity while particulate levels are elevated.

 

This is why temperature alone should not be used as an indication of overall indoor air quality.

 

By combining CO₂ + PM2.5 + PM10 + Temperature + Humidity, the TENMARS TM-380 gives users a more complete set of measurements for office IAQ investigation.

 

Looking for an Office Indoor Air Quality Monitor in Malaysia?

 

For Malaysian businesses, facility management companies and HVAC contractors looking for a portable multi-parameter IAQ instrument, the TENMARS TM-380 provides several important measurements in one unit.

 

It is suitable for investigating ventilation, particulate pollution and general indoor environmental conditions in offices and commercial buildings.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346

 

Contact MTM Precision for TENMARS TM-380 Multi IAQ Monitor enquiries in Malaysia.


 