TENMARS TM-380 Multi IAQ Monitor for Indoor Air Quality Monitoring Malaysia
TENMARS TM-380 Multi IAQ Monitor for Indoor Air Quality Monitoring Malaysia
Indoor air quality can change significantly throughout the day, especially in air-conditioned offices, classrooms, commercial buildings, laboratories and other enclosed environments.
A room may feel comfortable but still have elevated CO₂ levels or airborne particulate matter.
The TENMARS TM-380 Multi IAQ Monitor provides a convenient way to measure several important indoor air quality parameters with one portable instrument.
5 Important IAQ Parameters in One Meter
The TENMARS TM-380 is designed to measure:
CO₂
PM2.5
PM10
Temperature
Relative Humidity
Instead of carrying separate instruments for carbon dioxide, particulate matter and environmental conditions, technicians can perform multiple measurements using a single portable meter.
Why Measure CO₂?
CO₂ measurement is particularly useful when evaluating ventilation in occupied indoor spaces.
When people remain inside an enclosed or poorly ventilated room, CO₂ concentrations can gradually increase.
Monitoring CO₂ can therefore help facility teams investigate ventilation conditions in areas such as:
Offices
Meeting rooms
Training rooms
Classrooms
Commercial buildings
Air-conditioned workspaces
The TENMARS TM-380 uses an NDIR sensor for CO₂ measurement, making CO₂ monitoring one of its key functions.
Why PM2.5 and PM10 Matter
Indoor air quality is not only about ventilation.
Airborne particles can enter buildings from outdoor pollution, traffic, construction activities and haze. Particles may also be generated from activities taking place inside the building.
The TM-380 measures both PM2.5 and PM10 using a laser particulate matter sensor.
This makes it useful when checking particulate conditions before and after actions such as:
Operating an air purifier
Changing HVAC filters
Adjusting ventilation
Closing windows during poor outdoor air conditions
Investigating dusty indoor environments
Useful During Malaysia's Haze and Poor Air Quality Periods
During periods of elevated outdoor particulate pollution, checking only the outdoor AQI does not tell you exactly what is happening inside a particular office, classroom or building.
Indoor conditions depend on many factors, including building ventilation, filtration, open doors and windows, occupancy and air-cleaning equipment.
A portable instrument such as the TENMARS TM-380 allows users to take measurements directly inside the area they want to evaluate.
For example, measurements can be compared between:
Outdoor area → Building entrance → Office → Meeting room → Air purifier area
This can provide a much clearer picture of how particulate pollution varies throughout a building.
Check Ventilation and Particulate Pollution Together
One major advantage of the TM-380 is its ability to measure CO₂ and particulate matter with the same instrument.
These measurements can indicate different aspects of indoor air quality.
For example:
High CO₂ + Low PM2.5
The room may have relatively low particulate pollution but insufficient ventilation for its occupancy.
Low CO₂ + High PM2.5
Ventilation may be adequate, but particulate pollution could be entering from outdoors or being generated indoors.
High CO₂ + High PM2.5
Both ventilation and particulate conditions may require investigation.
This is why measuring only one IAQ parameter may not provide the complete picture.
Temperature and Humidity Monitoring
Temperature and relative humidity are also important when assessing indoor environmental conditions.
The TM-380 therefore allows technicians to view environmental comfort parameters alongside CO₂ and particulate measurements.
This combination is useful for HVAC technicians, facility managers and building maintenance teams investigating indoor environmental complaints.
Applications for TENMARS TM-380
The TM-380 can be considered for:
Office IAQ checking
Classroom monitoring
Commercial building inspection
Facility management
HVAC troubleshooting
Ventilation assessment
Air purifier performance checking
Indoor particulate monitoring
Haze-related indoor monitoring
Building maintenance
Workplace environmental checks
Alarm Indication
The TENMARS TM-380 provides warning indications for CO₂, PM2.5 and PM10, helping users identify elevated readings more easily during inspections.
This can be particularly useful when walking through multiple rooms or checking different areas of a building.
Data Recording Capability
For some IAQ investigations, a single measurement is not enough.
Indoor conditions can change according to occupancy, ventilation operation and activities throughout the day.
The TM-380 supports manual and automatic recording, allowing users to collect readings for further evaluation rather than relying only on an instantaneous measurement.
Who Should Consider the TENMARS TM-380?
The instrument can be useful for:
Facility managers
HVAC contractors
Building maintenance companies
Safety personnel
Environmental consultants
Schools and educational facilities
Commercial building operators
Industrial maintenance teams
IAQ service providers
For users who need to investigate several indoor air quality parameters without carrying multiple instruments, the TM-380 offers a practical portable solution.
Looking for an Indoor Air Quality Monitor in Malaysia?
If you need to monitor CO₂, PM2.5, PM10, temperature and humidity using one portable instrument, the TENMARS TM-380 is worth considering.
MTM Precision can assist Malaysian customers with product selection and application requirements for indoor air quality and environmental measurement instruments.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
Contact MTM Precision for TENMARS TM-380 Multi IAQ Monitor enquiries in Malaysia.
13 Aug 2026