Telescopic Probe Anemometer for HVAC Duct Measurement – TENMARS TM-4002 Malaysia

Telescopic Probe Anemometer for HVAC Duct Measurement – TENMARS TM-4002 Malaysia

 

Measuring airflow at an air-conditioning grille is relatively straightforward. Measuring airflow inside an HVAC duct can be more challenging because the required measurement point may be deep inside the duct or difficult to access with a conventional vane sensor.

 

The TENMARS TM-4002 Hot Wire Anemometer features a slim telescopic probe designed for HVAC airflow and duct measurement applications.

 

Why Is a Telescopic Probe Useful?

 

HVAC airflow is not always uniform throughout a duct.

 

Measurements may need to be taken further inside the duct rather than only at the opening.

 

The TM-4002 telescopic probe extends approximately from:

 

400 mm to 1020 mm

 

This provides additional reach for technicians performing measurements in ventilation and air-conditioning systems.

 

Typical applications include:

 

Supply air ducts

 

Return air ducts

 

Ventilation ducts

 

Exhaust systems

 

Air-conditioning systems

 

HVAC commissioning

 

Air balancing

 

Facility maintenance

 

Slim Hot Wire Sensor for Duct Testing

 

A conventional vane anemometer uses a rotating impeller, which can be convenient for measurements at larger openings and air outlets.

 

However, the sensor assembly is physically larger.

 

The TM-4002 uses hot wire sensing technology, allowing a slimmer probe to be used.

 

For technicians who regularly need to insert a sensor through suitable duct access points, this can be an important practical advantage.

 

Measure Air Velocity from 0.01 to 25.00 m/s

 

The TENMARS TM-4002 provides an air velocity measurement range of:

 

0.01 to 25.00 m/s

 

Available air velocity units include:

 

m/s

 

ft/min

 

km/hr

 

mph

 

knots

 

Its ability to measure relatively low air velocities makes the instrument particularly relevant to HVAC, ventilation and controlled-environment applications.

 

Why Take Measurements at Multiple Points?

 

Air inside a duct does not necessarily move at exactly the same velocity across the entire cross-section.

 

Factors such as duct geometry, bends, dampers and other system components can affect the airflow profile.

 

For this reason, professional HVAC testing may involve measurements at multiple positions according to the required testing method.

 

The telescopic probe allows technicians to position the sensor at different points inside the duct.

 

This can provide a more useful assessment than relying on a single reading.

 

Air Velocity and Air Volume Are Different

 

The TM-4002 can measure air velocity, but HVAC technicians frequently also need air volume information.

 

The instrument supports:

 

CFM – Cubic Feet per Minute

 

CMM – Cubic Metres per Minute

 

Air velocity indicates how quickly the air is moving, while air volume relates the airflow velocity to the cross-sectional area.

 

This information is useful when checking whether an HVAC system is delivering the required amount of air.

 

Useful for HVAC Air Balancing

 

During air balancing, technicians may compare airflow between:

 

Different duct branches

 

Different rooms

 

Multiple diffusers

 

Different floors

 

Supply air systems

 

Return air systems

 

Different HVAC zones

 

The TM-4002 can help provide measured data before and after system adjustments.

 

Instead of judging airflow by hand or visual observation, technicians can compare actual readings.

 

Temperature and Humidity Parameters

 

The TM-4002 provides more than airflow measurement.

 

It also measures:

 

Air temperature

 

Relative humidity

 

Dew point

 

Wet bulb temperature

 

These measurements are useful because HVAC performance involves both air movement and air condition.

 

A technician can therefore obtain several relevant parameters from one portable instrument.

 

99 Sets of Manual Data Memory

 

When testing a large HVAC system, many measurement points may be involved.

 

The TM-4002 provides 99 sets of manual data memory.

 

This can help technicians retain readings while checking multiple locations during inspection, commissioning or maintenance work.

 

MAX, MIN and HOLD functions are also available.

 

Applications for Telescopic Hot Wire Anemometers

 

The TM-4002 can be considered for airflow measurement in:

 

Commercial HVAC

 

Measure supply, return and ventilation airflow in commercial buildings.

 

Industrial Ventilation

 

Check air movement in factory ventilation and exhaust systems.

 

Cleanrooms

 

Measure relatively low air velocities in controlled environments.

 

Laboratories

 

Evaluate airflow conditions in laboratory ventilation systems.

 

Facility Management

 

Support routine HVAC inspections and preventive maintenance.

 

HVAC Commissioning

 

Verify airflow conditions during installation and system commissioning.

 

Typical Users in Malaysia

 

Potential users include:

 

HVAC contractors

 

M&E contractors

 

Air-conditioning service companies

 

Facility management companies

 

Building maintenance teams

 

Testing and commissioning companies

 

Engineering consultants

 

Cleanroom contractors

 

Industrial maintenance departments

 

Universities and laboratories

 

When Should You Choose a Telescopic Hot Wire Anemometer?

 

A telescopic hot wire instrument is worth considering when:

 

Measurement points are located inside HVAC ducts

 

Low air velocity measurement is required

 

A slim probe is easier to position

 

CFM or CMM airflow information is needed

 

Multiple duct positions need to be measured

 

HVAC environmental parameters are also useful

 

For these applications, the TM-4002 provides advantages beyond those of a basic handheld wind speed meter.

 

TENMARS TM-4002 Hot Wire Anemometer Malaysia

 

The combination of a 400–1020 mm telescopic probe, hot wire sensing technology, 0.01–25.00 m/s air velocity range, CFM/CMM measurement and environmental parameters makes the TENMARS TM-4002 particularly suitable for professional HVAC duct testing.

 

For enquiries about the TENMARS TM-4002 Telescopic Hot Wire Anemometer in Malaysia, contact MTM Precision.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


 

15 Aug 2026