How to Maintain and Store Myzox CL-28 CL-36 Auto Level Malaysia

How to Maintain and Store Myzox CL-28 CL-36 Auto Level Malaysia


The Myzox CL-28 and CL-36 Auto Levels are precision optical surveying instruments designed for construction leveling, benchmark transfer and civil engineering applications.


Proper handling, transportation, cleaning and storage can help maintain reliable instrument performance and reduce the risk of damage.


This is particularly important on construction sites where surveying equipment may be exposed to dust, vibration, moisture, heat and frequent transportation.


MTM Precision Sdn. Bhd. is an authorized distributor of Myzox in Malaysia, supplying professional Myzox surveying instruments and accessories.


Why Is Auto Level Maintenance Important?


An Auto Level contains precision optical and mechanical components.


Although it is designed for field use, unnecessary shock, contamination or poor storage can affect its condition.


Proper care helps protect:


Telescope optics


Focusing mechanism


Leveling mechanism


Compensator


Adjustment components


Instrument housing


Tribrach and leveling screws


Good maintenance also helps reduce unexpected problems when the instrument is required for important site measurements.


1. Always Use the Carrying Case


When the Auto Level is not being used, store it in its proper carrying case.


The case provides protection against:


Impact


Dust


Dirt


Accidental contact


Transportation movement


Avoid placing the Auto Level loosely in a vehicle together with heavy tools or construction equipment.


2. Protect the Instrument During Transportation


Construction surveying equipment is often transported between different job sites.


Repeated vibration and impact can potentially affect precision equipment.


When transporting the Myzox CL-28 or CL-36:


Keep it inside the carrying case


Secure the case inside the vehicle


Avoid placing heavy objects on top


Do not throw or drop the case


Minimize unnecessary vibration where possible


After unusually rough transportation, consider checking instrument performance before important work.


3. Do Not Carry the Auto Level Long Distances on the Tripod


For short repositioning on suitable ground, site procedures may vary.


However, carrying a precision instrument attached to a tripod over difficult terrain increases the risk of:


Impact


Tripod collision


Falling


Instrument damage


For significant movement between working locations, remove and transport the instrument appropriately.


4. Keep Optical Surfaces Clean


Dust, fingerprints and dirt on optical surfaces can reduce viewing clarity.


Optical surfaces should be cleaned carefully using appropriate optical cleaning materials and techniques.


Avoid:


Dirty cloth


Abrasive materials


Excessive pressure


Unnecessary touching of lenses


Do not treat precision optical surfaces like ordinary construction equipment.


5. Remove Loose Dust Carefully


Construction sites can contain cement dust, soil and other fine particles.


Before wiping an optical surface, remove loose particles using a suitable method to reduce the risk of scratching.


The instrument body can also be kept clean to prevent excessive dirt from accumulating around moving components.


6. Protect the Instrument from Excessive Moisture


Malaysia's humid and rainy environment means surveying equipment can frequently encounter moisture.


If the instrument becomes wet during field use, follow appropriate drying and storage procedures before long-term storage.


Avoid sealing a heavily wet instrument into its case for extended periods.


Persistent moisture can be undesirable for optical and mechanical equipment.


7. Avoid Extreme Heat Where Possible


Do not unnecessarily leave the Auto Level exposed inside an extremely hot vehicle for long periods.


Large temperature changes can also lead to condensation when equipment is moved between different environments.


Allow the instrument to acclimatize appropriately when moving between significantly different temperatures.


8. Do Not Force the Controls


Focusing knobs, leveling screws and other mechanical controls should operate normally.


If a component feels unusually tight or jammed, do not apply excessive force.


Forcing a precision mechanism may create additional damage.


Arrange inspection if operation appears abnormal.


9. Check the Tripod Regularly


The Auto Level may be in good condition while the tripod creates instability.


Check the tripod for:


Loose screws


Damaged clamps


Worn leg components


Loose head


Poor locking


Physical damage


A stable surveying tripod is essential for reliable leveling.


10. Check the Leveling Staff


The leveling staff is also part of the measurement system.


Inspect it for:


Physical damage


Loose sections


Difficult extension


Dirty graduations


Bent components


If the staff cannot be positioned properly, measurement reliability may be affected.


11. Check Instrument Performance After a Drop


If the Auto Level has been dropped or subjected to a strong impact, do not assume that it remains correctly adjusted.


Even when there is no obvious external damage, its measurement condition may have changed.


Consider:


Visual inspection


Basic operational check


Field verification such as an appropriate two-peg test


Professional inspection if accuracy is uncertain


This is especially important before critical engineering work.


12. Perform Periodic Accuracy Checks


An instrument can appear to operate normally while still requiring adjustment.


Periodic field checks can help identify potential issues.


The frequency should depend on:


How often the instrument is used


Site conditions


Transportation frequency


Project accuracy requirements


Previous impacts


Company quality procedures


Professional calibration or inspection may be required where documented accuracy is necessary.


Myzox CL-28 Specification


The Myzox CL-28 provides:


28X magnification


36 mm objective aperture


0.4 m minimum focusing distance


±2.0 mm accuracy for 1 km double-run leveling


±15′ self-leveling range


360° horizontal circle


Approx. 1.3 kg weight


Myzox CL-36 Specification


The Myzox CL-36 provides:


36X magnification


36 mm objective aperture


0.4 m minimum focusing distance


±1.0 mm accuracy for 1 km double-run leveling


±15′ self-leveling range


360° horizontal circle


Approx. 1.3 kg weight


Regardless of model, good instrument care remains important.


Daily Auto Level Care Checklist


Before use:


Inspect the instrument


Check tripod stability


Check the leveling staff


Confirm normal focusing


Confirm leveling mechanism operation


After use:


Remove dirt and dust


Check for moisture


Place the instrument in its carrying case


Store it safely


Report any impact or abnormal operation


Simple daily habits can help protect surveying equipment over the long term.


Long-Term Storage


If the instrument will not be used for an extended period:


Clean it before storage


Make sure it is appropriately dry


Keep it in its carrying case


Store it in a suitable indoor environment


Avoid unnecessary heat and moisture


Protect it from impact


Before returning the instrument to important field work, verify its operating condition.


Frequently Asked Questions


How should I store a Myzox Auto Level?


Keep it clean, appropriately dry and protected inside its carrying case in a suitable storage environment.


Can I leave an Auto Level inside a vehicle?


Avoid unnecessary prolonged exposure to extreme heat and uncontrolled storage conditions.


What should I do if the Auto Level gets wet?


Follow appropriate drying procedures before long-term storage and avoid leaving a heavily wet instrument sealed in its case.


Should I check the instrument after dropping it?


Yes. Its measurement performance should be verified before it is used for critical work.


How often should an Auto Level be checked?


The interval depends on usage, transportation, site conditions and project requirements.


Does the CL-36 require more maintenance than the CL-28?


Both are precision optical instruments and should receive appropriate handling, storage and periodic checking.


Myzox Auto Level Supplier Malaysia


MTM Precision supplies Myzox CL-28, CL-36 and professional surveying accessories in Malaysia.


As an authorized distributor of Myzox in Malaysia, we support contractors, engineers and survey professionals requiring reliable surveying instruments and after-sales support.


Contact MTM Precision


MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.


Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-6607346


Contact MTM Precision for enquiries about the Myzox CL-28, CL-36 Auto Level and professional surveying equipment in Malaysia.



16 Aug 2026