How to Maintain and Store Myzox CL-28 CL-36 Auto Level Malaysia

How to Maintain and Store Myzox CL-28 CL-36 Auto Level Malaysia

 

The Myzox CL-28 and CL-36 Auto Levels are precision optical surveying instruments designed for construction leveling, benchmark transfer and civil engineering applications.

 

Proper handling, transportation, cleaning and storage can help maintain reliable instrument performance and reduce the risk of damage.

 

This is particularly important on construction sites where surveying equipment may be exposed to dust, vibration, moisture, heat and frequent transportation.

 

MTM Precision Sdn. Bhd. is an authorized distributor of Myzox in Malaysia, supplying professional Myzox surveying instruments and accessories.

 

Why Is Auto Level Maintenance Important?

 

An Auto Level contains precision optical and mechanical components.

 

Although it is designed for field use, unnecessary shock, contamination or poor storage can affect its condition.

 

Proper care helps protect:

 

Telescope optics

 

Focusing mechanism

 

Leveling mechanism

 

Compensator

 

Adjustment components

 

Instrument housing

 

Tribrach and leveling screws

 

Good maintenance also helps reduce unexpected problems when the instrument is required for important site measurements.

 

1. Always Use the Carrying Case

 

When the Auto Level is not being used, store it in its proper carrying case.

 

The case provides protection against:

 

Impact

 

Dust

 

Dirt

 

Accidental contact

 

Transportation movement

 

Avoid placing the Auto Level loosely in a vehicle together with heavy tools or construction equipment.

 

2. Protect the Instrument During Transportation

 

Construction surveying equipment is often transported between different job sites.

 

Repeated vibration and impact can potentially affect precision equipment.

 

When transporting the Myzox CL-28 or CL-36:

 

Keep it inside the carrying case

 

Secure the case inside the vehicle

 

Avoid placing heavy objects on top

 

Do not throw or drop the case

 

Minimize unnecessary vibration where possible

 

After unusually rough transportation, consider checking instrument performance before important work.

 

3. Do Not Carry the Auto Level Long Distances on the Tripod

 

For short repositioning on suitable ground, site procedures may vary.

 

However, carrying a precision instrument attached to a tripod over difficult terrain increases the risk of:

 

Impact

 

Tripod collision

 

Falling

 

Instrument damage

 

For significant movement between working locations, remove and transport the instrument appropriately.

 

4. Keep Optical Surfaces Clean

 

Dust, fingerprints and dirt on optical surfaces can reduce viewing clarity.

 

Optical surfaces should be cleaned carefully using appropriate optical cleaning materials and techniques.

 

Avoid:

 

Dirty cloth

 

Abrasive materials

 

Excessive pressure

 

Unnecessary touching of lenses

 

Do not treat precision optical surfaces like ordinary construction equipment.

 

5. Remove Loose Dust Carefully

 

Construction sites can contain cement dust, soil and other fine particles.

 

Before wiping an optical surface, remove loose particles using a suitable method to reduce the risk of scratching.

 

The instrument body can also be kept clean to prevent excessive dirt from accumulating around moving components.

 

6. Protect the Instrument from Excessive Moisture

 

Malaysia's humid and rainy environment means surveying equipment can frequently encounter moisture.

 

If the instrument becomes wet during field use, follow appropriate drying and storage procedures before long-term storage.

 

Avoid sealing a heavily wet instrument into its case for extended periods.

 

Persistent moisture can be undesirable for optical and mechanical equipment.

 

7. Avoid Extreme Heat Where Possible

 

Do not unnecessarily leave the Auto Level exposed inside an extremely hot vehicle for long periods.

 

Large temperature changes can also lead to condensation when equipment is moved between different environments.

 

Allow the instrument to acclimatize appropriately when moving between significantly different temperatures.

 

8. Do Not Force the Controls

 

Focusing knobs, leveling screws and other mechanical controls should operate normally.

 

If a component feels unusually tight or jammed, do not apply excessive force.

 

Forcing a precision mechanism may create additional damage.

 

Arrange inspection if operation appears abnormal.

 

9. Check the Tripod Regularly

 

The Auto Level may be in good condition while the tripod creates instability.

 

Check the tripod for:

 

Loose screws

 

Damaged clamps

 

Worn leg components

 

Loose head

 

Poor locking

 

Physical damage

 

A stable surveying tripod is essential for reliable leveling.

 

10. Check the Leveling Staff

 

The leveling staff is also part of the measurement system.

 

Inspect it for:

 

Physical damage

 

Loose sections

 

Difficult extension

 

Dirty graduations

 

Bent components

 

If the staff cannot be positioned properly, measurement reliability may be affected.

 

11. Check Instrument Performance After a Drop

 

If the Auto Level has been dropped or subjected to a strong impact, do not assume that it remains correctly adjusted.

 

Even when there is no obvious external damage, its measurement condition may have changed.

 

Consider:

 

Visual inspection

 

Basic operational check

 

Field verification such as an appropriate two-peg test

 

Professional inspection if accuracy is uncertain

 

This is especially important before critical engineering work.

 

12. Perform Periodic Accuracy Checks

 

An instrument can appear to operate normally while still requiring adjustment.

 

Periodic field checks can help identify potential issues.

 

The frequency should depend on:

 

How often the instrument is used

 

Site conditions

 

Transportation frequency

 

Project accuracy requirements

 

Previous impacts

 

Company quality procedures

 

Professional calibration or inspection may be required where documented accuracy is necessary.

 

Myzox CL-28 Specification

 

The Myzox CL-28 provides:

 

28X magnification

 

36 mm objective aperture

 

0.4 m minimum focusing distance

 

±2.0 mm accuracy for 1 km double-run leveling

 

±15′ self-leveling range

 

360° horizontal circle

 

Approx. 1.3 kg weight

 

Myzox CL-36 Specification

 

The Myzox CL-36 provides:

 

36X magnification

 

36 mm objective aperture

 

0.4 m minimum focusing distance

 

±1.0 mm accuracy for 1 km double-run leveling

 

±15′ self-leveling range

 

360° horizontal circle

 

Approx. 1.3 kg weight

 

Regardless of model, good instrument care remains important.

 

Daily Auto Level Care Checklist

 

Before use:

 

Inspect the instrument

 

Check tripod stability

 

Check the leveling staff

 

Confirm normal focusing

 

Confirm leveling mechanism operation

 

After use:

 

Remove dirt and dust

 

Check for moisture

 

Place the instrument in its carrying case

 

Store it safely

 

Report any impact or abnormal operation

 

Simple daily habits can help protect surveying equipment over the long term.

 

Long-Term Storage

 

If the instrument will not be used for an extended period:

 

Clean it before storage

 

Make sure it is appropriately dry

 

Keep it in its carrying case

 

Store it in a suitable indoor environment

 

Avoid unnecessary heat and moisture

 

Protect it from impact

 

Before returning the instrument to important field work, verify its operating condition.

 

Frequently Asked Questions

 

How should I store a Myzox Auto Level?

 

Keep it clean, appropriately dry and protected inside its carrying case in a suitable storage environment.

 

Can I leave an Auto Level inside a vehicle?

 

Avoid unnecessary prolonged exposure to extreme heat and uncontrolled storage conditions.

 

What should I do if the Auto Level gets wet?

 

Follow appropriate drying procedures before long-term storage and avoid leaving a heavily wet instrument sealed in its case.

 

Should I check the instrument after dropping it?

 

Yes. Its measurement performance should be verified before it is used for critical work.

 

How often should an Auto Level be checked?

 

The interval depends on usage, transportation, site conditions and project requirements.

 

Does the CL-36 require more maintenance than the CL-28?

 

Both are precision optical instruments and should receive appropriate handling, storage and periodic checking.

 

Myzox Auto Level Supplier Malaysia

 

MTM Precision supplies Myzox CL-28, CL-36 and professional surveying accessories in Malaysia.

 

As an authorized distributor of Myzox in Malaysia, we support contractors, engineers and survey professionals requiring reliable surveying instruments and after-sales support.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-6607346

 

Contact MTM Precision for enquiries about the Myzox CL-28, CL-36 Auto Level and professional surveying equipment in Malaysia.


 