Workers Complain About Poor Air Quality in Factory What Should You Test Malaysia

Workers Complain About Poor Air Quality in Factory What Should You Test Malaysia Workers may complain: “The air feels stuffy.” “There is a strange smell.” “I get headaches after working here.” “The production area feels uncomfortable.” “The ventilation seems poor.” When this happens, buying a random air quality meter is not the best starting point. Poor indoor air quality can involve several different factors. The better question is: What should we measure to understand the problem? A factory indoor air quality investigation may involve: CO → PM2.5 / PM10 → VOC → Formaldehyde → Carbon Monoxide → Temperature → Humidity → Airflow The correct combination depends on the workplace and suspected source. 1. Start With the Workers' Complaint Different complaints can point towards different measurement priorities. For example: “The room feels stuffy.” Possible investigation: CO → Temperature → Humidity → Airflow “There is a chemical smell.” Possible investigation: VOC → Process-Specific Gas → Ventilation “There is a lot of dust.” Possible investigation: PM2.5 → PM10 → Dust Source “Workers feel uncomfortable in the afternoon.” Possible investigation: Temperature → Humidity → CO → Time-Based Monitoring There is rarely one instrument that answers every indoor air quality question. 2. Check Carbon Dioxide CO measurement can be useful when investigating ventilation and occupied indoor spaces. Higher CO readings can indicate that fresh-air ventilation may need further investigation, particularly where many people occupy an enclosed area. Potential locations include: Offices inside factories Meeting rooms Control rooms Laboratories Training rooms Enclosed production areas Staff rooms However, CO is only one parameter. A good CO reading does not automatically mean every aspect of indoor air quality is acceptable. 3. Measure PM2.5 and PM10 Factories can generate airborne particles from many processes. Examples include: Grinding Cutting Sanding Powder handling Cement Woodworking Packaging Material transfer Vehicle movement General production activity Particulate monitoring may include: PM2.5 and PM10 Measurements can help compare different locations and operating conditions. 4. Investigate VOCs When Chemicals Are Involved VOC stands for Volatile Organic Compounds. Potential sources can include: Solvents Paint Adhesives Cleaning chemicals Printing processes Coatings Manufacturing chemicals Stored chemical products If workers report an unusual chemical smell, VOC measurement may form part of the investigation. But VOC measurement should not automatically replace testing for a specific known hazardous gas. The process and chemicals involved should always be considered. 5. What About Formaldehyde? Formaldehyde may be relevant in certain environments involving: Building materials Furniture Adhesives Resins Wood products Manufacturing processes Renovation materials If formaldehyde is a suspected contaminant, a suitable HCHO measurement instrument may be considered. Again, the instrument should follow the suspected problem not the other way around. 6. Carbon Monoxide Can Be a Different Problem Carbon monoxide is particularly important around combustion sources. Potential sources include: Engines Generators Forklifts Boilers Furnaces Vehicles Poorly ventilated combustion equipment If combustion is involved, CO measurement may need to be considered separately from general indoor air quality measurements. 7. Temperature and Humidity Matter Sometimes workers describe the problem as “bad air,” but the main issue may be thermal discomfort. High temperature and humidity can make a workplace feel: Hot Sticky Stuffy Uncomfortable Low humidity may also create discomfort in certain environments. Therefore: Temperature + Relative Humidity are useful supporting measurements during many workplace environmental investigations. 8. Don't Forget Airflow You can have an air-conditioned room and still have poor air distribution. Possible problems include: Blocked vents Weak airflow Poor fresh-air supply Incorrect air distribution Dead zones Inadequate exhaust Production changes affecting ventilation An anemometer can help investigate air velocity at: Supply vents Exhaust points Workstations Production areas Duct outlets This connects indoor air quality measurement with ventilation troubleshooting. 9. Measure Different Locations Do not take only one reading near the entrance. Compare areas such as: Outside Air ↓ Office ↓ Production Area ↓ Chemical Area ↓ Worker Position ↓ Warehouse ↓ Ventilation Supply / Exhaust Comparing locations can provide more useful information than one isolated measurement. 10. Measure at Different Times Indoor air conditions can change significantly throughout the day. For example: 8:00 AM Factory starts operation. 10:00 AM Production increases. 1:00 PM Temperature rises. 3:00 PM Occupancy and production continue. 5:00 PM Conditions may differ again. A single reading may miss these changes. For changing conditions, consider: Data Logger → Continuous Monitoring → Trend Analysis 11. Look at the Production Process One of the most important questions is: What happens in this area? For example: Welding Area Possible concerns: Particles → Fumes → Gas → Heat → Ventilation Painting Area Possible concerns: VOC → Solvent Vapour → Ventilation Grinding Area Possible concerns: PM → Noise → Airflow Generator Room Possible concerns: CO → Temperature → Noise → Ventilation Office Inside Factory Possible concerns: CO → Temperature → Humidity → PM → VOC Different workplaces require different measurement strategies. Example: Workers Complain About Headaches Suppose a customer contacts MTM and says: “Several workers complain of headaches in the afternoon. What meter should we buy?” It would be premature to immediately recommend one instrument. We first need to understand: Where are they working? How many people occupy the area? Is there air conditioning? Is fresh air supplied? Are chemicals used nearby? Are there combustion sources? Does the complaint happen at a particular time? From there, a possible measurement approach might be: CO ↓ Temperature & Humidity ↓ PM2.5 / PM10 ↓ VOC / HCHO where relevant ↓ CO where combustion is possible ↓ Airflow ↓ Long-Term Monitoring That is a measurement solution not simply a product recommendation. One Complaint May Require Several Measurements Poor air quality is a perfect example of why MTM should not be viewed simply as a company with hundreds of instruments. The customer does not need to understand every SKU. The customer needs help answering: “What is causing our problem?” The measurement pathway may include: CO Meter Air Quality Meter Particle Meter VOC / Formaldehyde Meter Carbon Monoxide Meter Temperature & Humidity Meter Anemometer Data Logger Which instruments are appropriate depends on the actual environment and objective. From Complaint to Measurement Solution MTM's approach is: Worker Complaint ↓ Understand the Workplace ↓ Identify Possible Parameters ↓ Select Suitable Instruments ↓ Measure ↓ Compare Locations and Times ↓ Investigate the Source ↓ Take Corrective Action ↓ Measure Again This is more useful than simply asking: “Which air quality meter is cheapest?” Factory Environmental & Safety Measurement Solutions Malaysia MTM Precision supports factories, EHS teams, facility managers, maintenance departments, engineers and contractors with testing and measurement solutions covering: Indoor Air Quality CO PM2.5 / PM10 VOC Formaldehyde Carbon Monoxide Temperature & Humidity Airflow Heat Stress Noise Gas Detection Industrial Maintenance You do not have to know which instrument you need before contacting us. Tell us the problem first. Need Help Investigating Poor Factory Air Quality? Tell MTM: What are workers experiencing? Where is it happening? What processes or chemicals are nearby? When does the problem occur? We can help identify suitable measurement parameters and instruments for the application. MTM Precision Sdn Bhd Showroom & Service Centre No. 29-1 & 29-2, Jalan Banda 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Website: www.mtmpre.com.my Tell us your testing problem. MTM will help you find the right measurement solution.

21 Aug 2026