Factory Warehouse Environmental Problems What Should You Measure Malaysia

Factory Warehouse Environmental Problems What Should You Measure Malaysia A warehouse manager may report: “The warehouse becomes very hot in the afternoon.” “Some cartons feel damp.” “We are worried about humidity during the rainy season.” “There is a lot of dust when forklifts are moving.” “Some aisles are too dark.” “We don't know what happens to temperature overnight.” These may sound like separate problems. But they all belong to one larger question: What environmental conditions are our products and workers actually experiencing inside the warehouse? A practical investigation may involve: Temperature → Humidity → Data Logging → Material Moisture → Airflow → PM2.5 / PM10 → Lux The correct starting point is not: “Which warehouse meter should we buy?” It is: “What is happening to the warehouse, the stored products or the workers?” 1. Start With What Is Being Stored Different products can have different environmental sensitivities. Ask: What products are stored? How long are they stored? Are they sensitive to heat? Are they sensitive to humidity? Is packaging affected by moisture? Are there manufacturer storage requirements? Which part of the warehouse has the problem? The measurement plan should follow the storage requirement. 2. One Temperature Reading Is Not a Warehouse Temperature Study Suppose the warehouse supervisor checks: 9:00 AM → 29°C and concludes: “Temperature is okay.” But the warehouse may reach a much higher temperature at: 2:00 PM or 4:00 PM. A single measurement is only a snapshot. If the problem changes throughout the day, time-based monitoring becomes much more useful. 3. Use Temperature Data Logging A temperature data logger can help record conditions across: Morning → Afternoon → Night → Weekend This can reveal: Peak temperature Minimum temperature Daily cycles Overnight conditions Changes during loading Changes during shutdown periods Instead of: “The warehouse feels hotter in the afternoon.” you have a temperature history. 4. Humidity Can Be Just as Important In Malaysia, warehouse humidity can be an important concern. Depending on the stored product, high humidity may contribute to problems involving: Packaging Paper Cartons Wood Electronics Metal components Stored materials Therefore, many warehouse investigations should consider: Temperature + Relative Humidity rather than temperature alone. 5. Monitor Temperature and Humidity Together A temperature / humidity data logger can help reveal whether the warehouse experiences environmental cycles. For example: Morning Lower Temperature / Higher RH Afternoon Higher Temperature / Different RH Night Conditions Change Again This can be more useful than occasional manual checks. 6. One Warehouse Can Have Several Micro-Environments A large warehouse may not have uniform conditions. Compare: Near Roller Shutter Centre Rear Upper Rack Lower Rack Near Roof Near External Wall Air-Conditioned Section Different locations can behave differently. 7. Measure at Different Heights This is especially important in high-bay warehouses. Temperature near the roof may differ from conditions near floor level. Depending on the objective, place sensors at representative: Low Middle and High locations. This helps build a warehouse environmental map. 8. Don't Put Every Logger Beside the Office If the complaint is: “Products at the rear upper racks are affected.” placing a logger beside the warehouse office will not answer the question. The sensor should be located where the problem occurs. Measurement location matters as much as instrument selection. 9. Material Moisture May Be a Different Problem Suppose workers say: “The cartons feel damp.” or: “This wood seems wetter than usual.” Now the problem may not be solved by measuring room humidity alone. Depending on the material, an appropriate moisture meter may help investigate the material itself. This creates two different questions: What is the warehouse environment? and What is the moisture condition of the material? 10. Environmental Humidity and Material Moisture Are Not the Same This distinction is important. A humidity meter measures: Relative humidity in the air. A moisture meter is used for appropriate measurement of: Moisture condition in a material. One should not automatically be substituted for the other. 11. Airflow Can Explain Hot Zones Suppose the front of the warehouse feels acceptable but the rear becomes very hot. Possible factors may include: Poor air circulation Roof heat Blocked ventilation Rack arrangement Closed shutters Weak fans An anemometer can help investigate air velocity. 12. Measure Airflow at the Problem Area Possible locations include: Ventilation Opening Fan Outlet Warehouse Centre Rear Storage Area Worker Position This helps determine whether air movement differs across the warehouse. 13. Forklift Traffic Can Increase Dust Warehouse particulate can come from: Forklift movement Outdoor road dust Pallets Packaging Material handling Loading activity Nearby production For appropriate screening, a PM2.5 / PM10 meter can help compare particulate conditions. 14. Compare Low and High Activity For example: Early Morning Few vehicles moving. Peak Loading Period Multiple forklifts and trucks operating. Compare relevant particulate measurements. This can help identify whether activity is associated with increased airborne particles. 15. Check Whether Outdoor Dust Is Entering Possible measurement locations: Outdoor Loading Area ↓ Roller Shutter ↓ Warehouse Entrance ↓ Warehouse Interior This can help investigate whether particulate conditions change from outside to inside. 16. Warehouse Lighting Is Another Common Problem Tall racks can block light. Workers may have difficulty: Reading labels Picking products Checking part numbers Inspecting cartons Driving forklifts Walking safely A lux meter can help quantify illumination at the actual work location. 17. Measure Aisles and Picking Locations Do not measure only in the brightest open area. Consider: Main Aisle Rack Aisle Picking Position Packing Station Loading Area Pedestrian Route The measurement should represent the task. 18. Compare Day and Night Conditions A warehouse with skylights or open loading doors may appear bright during the day. The night shift can be completely different. Compare: Day Shift versus Night Shift where lighting is a concern. 19. Example: Products at Upper Rack Keep Getting Hot Suppose a customer contacts MTM: “Products on the upper racks seem much hotter than products near the floor.” Do not immediately recommend one thermometer. A better investigation is: Place Temperature / Humidity Loggers at Multiple Heights ↓ Monitor Several Days ↓ Compare Low / Middle / High Rack ↓ Measure Airflow ↓ Investigate Heat Accumulation ↓ Corrective Action ↓ Monitor Again This creates a warehouse temperature-mapping solution. 20. Example: Cartons Become Damp During Rainy Periods Another customer says: “Some cartons feel damp during the rainy season.” Possible investigation: Temperature / Humidity Logging ↓ Compare Different Warehouse Zones ↓ Measure Material Moisture Where Appropriate ↓ Check Ventilation / Water Ingress ↓ Corrective Action ↓ Monitor Again The problem requires both environmental and material measurements. 21. Example: Warehouse Is Dusty During Loading Another customer says: “The warehouse becomes dusty whenever the loading bay is busy.” Possible pathway: PM2.5 / PM10 Screening ↓ Compare Low / High Activity ↓ Compare Loading Bay / Warehouse ↓ Check Airflow ↓ Identify Dust Source ↓ Corrective Action ↓ Measure Again Again, the instrument follows the problem. What Instruments Might Be Needed? Depending on the problem, a warehouse measurement solution may include: Temperature & Humidity Meter For spot environmental checks. Temperature / Humidity Data Logger For continuous monitoring. Moisture Meter For appropriate material-moisture measurements. Anemometer For airflow and ventilation investigation. PM2.5 / PM10 Meter For appropriate particulate screening. Lux Meter For warehouse illumination measurements. Indoor Air Quality Meter Where broader environmental screening is relevant. Not every warehouse needs every instrument. The correct combination depends on: Stored Product + Worker Complaint + Environment + Measurement Objective Don't Search for One “Warehouse Meter” There is no single meter that answers: Is the warehouse too hot? Is humidity too high? Are products absorbing moisture? Is dust increasing? Is ventilation poor? Are aisles too dark? These are different measurement questions. From Warehouse Problem to Measurement Solution The better approach is: Identify Product / Worker Problem ↓ Identify Location ↓ Determine Measurement Parameters ↓ Spot Check or Data Logging ↓ Compare Warehouse Zones ↓ Investigate Airflow / Dust / Lighting ↓ Corrective Action ↓ Measure Again This turns a general warehouse complaint into measurable information. One Warehouse Can Require a Complete Environmental Measurement System Storage Environment Temperature → Humidity → Data Logging Product Condition Material Moisture Air Environment PM2.5 / PM10 → Airflow Workplace Safety Lux The customer does not need to know which catalogue category each instrument belongs to. They only need to tell MTM: “We have a problem in our warehouse.” Then we help determine what needs to be measured. Factory Warehouse Environmental & Safety Measurement Solutions Malaysia MTM Precision supports: Manufacturing plants Warehouses Distribution centres Logistics facilities Facility managers Warehouse managers EHS departments Quality teams Maintenance departments with measurement solutions covering: Temperature Humidity Data Logging Material Moisture PM2.5 / PM10 Airflow Ventilation Lux Indoor Air Quality Environmental Monitoring MTM's value is not: “We have 500 different instruments.” It is: “Tell us what is happening to your warehouse, products or workers. We help identify what needs to be measured.” Need Help Investigating a Warehouse Environmental Problem? Tell MTM: What products are you storing? Is the problem temperature, humidity, moisture, dust, ventilation or lighting? Where in the warehouse does it happen? Does it occur at a particular time or season? Do you need a spot measurement or continuous monitoring? We can help identify suitable measurement options for your application. MTM Precision Sdn Bhd Showroom & Service Centre No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Website: www.mtmpre.com.my Tell us your testing problem. MTM will help you find the right measurement solution.

21 Aug 2026