Factory Too Hot What Should You Measure When Workers Complain About Heat Malaysia

Factory Too Hot What Should You Measure When Workers Complain About Heat Malaysia One of the most common workplace complaints in Malaysia is: “The factory is too hot.” Workers may say: “Morning is okay, but afternoon is very hot.” “This production line is much hotter than the others.” “The exhaust fans are running but we still feel hot.” “Workers near the oven cannot stand there for long.” “The warehouse roof makes the whole area hot.” The first reaction may be: “We need a thermometer.” But factory heat is not always a single temperature problem. A proper investigation may involve: Air Temperature → Humidity → Radiant Heat → Air Movement → Workload → Heat Stress → Ventilation → Hot Equipment The better question is: Why is this work area hot, when is it worst, and what are workers actually exposed to? 1. Start With the Worker Before choosing an instrument, ask: Who is affected? Where are they working? What task are they performing? How physically demanding is the work? What PPE or clothing is worn? How long are they in the hot area? At what time is the complaint worst? Heat investigation starts with the actual work environment. 2. “Factory Temperature” Is Not One Number A factory can contain: 28°C Office 31°C Warehouse Hot Production Line Very Hot Oven Area Outdoor Loading Bay all at the same time. One temperature measurement at reception tells you almost nothing about worker conditions elsewhere. 3. Map the Hot Areas A useful first investigation may compare: Production Line A Production Line B Oven Area Warehouse Loading Bay Worker Rest Area This helps identify the actual hot zones. 4. Time Matters Malaysia's factory environment can change significantly throughout the day. A useful comparison may be: 9:00 AM ↓ 12:00 PM ↓ 3:00 PM ↓ 5:00 PM If workers complain only in the afternoon, measure in the afternoon. 5. Don't Investigate a 3 PM Complaint at 9 AM This sounds obvious, but it is a common measurement mistake. If the factory says: “The problem starts after lunch.” a morning spot reading may completely miss the condition. Measure during the actual complaint period or use appropriate logging. 6. Temperature and Humidity Are a Useful Starting Point A temperature / humidity meter can help quantify basic environmental conditions. Humidity matters because thermal comfort and heat conditions are influenced by more than air temperature alone. For general troubleshooting: Temperature + Relative Humidity is often a useful first measurement. 7. But Heat Stress Is More Than Room Temperature Suppose two areas both show similar air temperature. One area is beside: Hot machinery or radiant heat while another is not. Worker heat conditions may be very different. This is why ordinary temperature alone may not answer an occupational heat-stress question. 8. WBGT May Be Appropriate Where occupational heat stress is being assessed, WBGT may be an appropriate measurement approach depending on the applicable assessment requirements. WBGT considers thermal environmental factors differently from a normal thermometer. The key point is: Room Temperature ≠ Complete Heat-Stress Assessment 9. Measure Where Workers Actually Work Do not place the instrument: Inside the air-conditioned supervisor office when the affected worker is beside: An oven. Measurements should represent the actual work environment and assessment objective. 10. Different Jobs Can Have Different Heat Exposure Consider: Worker A Standing near packing machine. Worker B Loading heavy material beside furnace. Even in the same building, their thermal conditions and physical workload can be very different. Therefore, heat investigation should be job-specific where appropriate. 11. Air Movement Can Make a Big Difference A factory may be hot partly because air movement is poor. Possible causes include: Weak exhaust Poor cross ventilation Blocked louvres Incorrect fan positioning Factory layout changes Stored materials blocking airflow An anemometer can help investigate air velocity. 12. “We Installed More Fans” Does Not Automatically Solve the Problem More fans may increase local air movement. But the factory still needs to understand: Where is hot air going? Is fresh air entering? Is hot air being exhausted? Is air simply circulating inside the same hot space? This turns the problem into a ventilation investigation. 13. Measure Airflow at Relevant Locations Depending on the facility, compare appropriate: Fresh-Air Inlet Worker Position Exhaust Louvre Hot Process Area Adjacent Cooler Area This can help understand the air movement pattern. 14. Hot Machines Can Be Part of the Problem Heat may come from: Ovens Furnaces Boilers Compressors Motors Steam pipes Production equipment Heated products Suitable temperature instruments can help investigate equipment or surface temperature where appropriate. 15. Air Temperature and Surface Temperature Are Different An infrared thermometer may be useful for suitable surface-temperature checks. But it should not be treated as a replacement for an air-temperature or WBGT instrument. Ask: What are you trying to measure? Air? Worker heat environment? Machine surface? The target determines the instrument. 16. Roof Heat Can Affect Warehouses A warehouse under a metal roof may become significantly hotter during the afternoon. A useful investigation may compare: Morning versus Afternoon and: Near Roof / Upper Area versus Worker Level depending on the objective. This can support ventilation or insulation investigations. 17. Data Logging Helps When Conditions Change Throughout the Day Instead of sending someone to manually check every hour, a suitable logger can record environmental conditions continuously. This helps reveal: When temperature starts rising When the peak occurs How long the hot condition lasts When conditions return to normal Trend data is often more useful than one spot reading. 18. Compare Production OFF and Production ON Suppose the factory is comfortable before production starts. Then the temperature rises after several machines operate. Compare: Production OFF ↓ Partial Production ↓ Full Production This can help determine how much the process contributes to the heat problem. 19. Compare Before and After Ventilation Improvement Suppose maintenance installs or services an exhaust system. Do not stop at: “Workers say it feels better.” Where appropriate, compare: Temperature / Heat Condition Before Air Velocity Before versus: Temperature / Heat Condition After Air Velocity After This provides measurable verification. 20. Example: Production Area Gets Very Hot After Lunch Factory complaint: “The production floor becomes extremely hot between 1 PM and 4 PM.” Possible pathway: Temperature / Humidity ↓ WBGT Where Appropriate ↓ Measure Air Velocity ↓ Compare Hot Zones ↓ Identify Process / Solar Heat Sources ↓ Investigate Ventilation ↓ Corrective Action ↓ Measure Again Now the factory knows what is actually changing. 21. Example: Workers Near Oven Complain About Heat Customer: “Only the workers near the oven complain.” Possible investigation: Worker Location ↓ Heat-Stress Measurement Where Appropriate ↓ Air Velocity ↓ Surface / Process Temperature Where Relevant ↓ Compare Nearby Work Areas ↓ Review Ventilation / Shielding / Work Controls ↓ Measure Again The solution is specific to the work scene. 22. Example: Warehouse Is Hot Even With Many Fans Customer: “We installed fans everywhere but the warehouse is still hot.” Possible pathway: Temperature Mapping ↓ Humidity ↓ Air Velocity Mapping ↓ Identify Fresh-Air Entry ↓ Identify Exhaust Path ↓ Check Hot-Air Recirculation ↓ Corrective Action ↓ Repeat Measurements This is much stronger than selling another fan or thermometer. 23. Example: Factory Wants a WBGT Meter Customer: “We need a WBGT meter.” MTM should still ask: Indoor or outdoor? What work activity? Which area? How many locations? Spot measurement or ongoing monitoring? What assessment procedure are you following? This helps select an instrument that matches the intended use. 24. Don't Confuse WBGT With an Ordinary Thermometer A normal temperature meter is useful. A WBGT meter is useful. But they answer different questions. Thermometer What is the temperature? WBGT Supports appropriate assessment of: Thermal stress conditions depending on the methodology used. Choose based on the question. 25. Build a Factory Heat Map Instead of writing: “Factory = 33°C” create a structured picture. For example: AreaMorningAfternoonWorker ComplaintPackingLowerHigherMildProductionLowerHigherModerateOven AreaHighVery HighStrongWarehouseLowerHighModerateRest AreaLowerLowerLow Then add appropriate: Humidity WBGT Air Velocity where required. Now the factory can prioritize action. 26. Heat Measurement Should Lead to Action The purpose is not: Measure → Write Number → Finish The useful cycle is: Measure ↓ Identify Hot Zone / Time ↓ Investigate Cause ↓ Improve Ventilation / Engineering or Work Controls as Appropriate ↓ Measure Again ↓ Continue Monitoring Measurement supports decisions. What Instruments Might Be Needed? Depending on the heat problem, a solution may include: Temperature & Humidity Meter For basic environmental measurements. Temperature / Humidity Data Logger For continuous trend monitoring. WBGT Meter For appropriate occupational heat-stress assessment. Anemometer For airflow and ventilation investigation. Infrared Thermometer For suitable non-contact surface-temperature checks. Contact Temperature Instrument Where contact measurement is more appropriate. Not every hot factory needs every instrument. The correct combination depends on: Worker + Process + Heat Source + Time + Airflow + Assessment Objective Don't Search Only for “Factory Temperature Meter” A factory heat complaint can involve: Temperature Humidity Radiant Heat Air Movement Physical Workload Hot Equipment Roof Heat Ventilation One thermometer gives only one part of the picture. From “Factory Too Hot” to Measurement Solution The better approach is: Workers Report Heat ↓ Identify Area / Job ↓ Identify Worst Time ↓ Temperature / Humidity ↓ Heat-Stress Measurement Where Appropriate ↓ Air Velocity ↓ Identify Heat Sources ↓ Investigate Ventilation ↓ Corrective Action ↓ Measure Again This is a workplace heat investigation. One Heat Complaint Can Connect Multiple MTM Solutions Environmental Monitoring Temperature → Humidity → Data Logging Occupational Safety WBGT → Heat-Stress Investigation Ventilation Air Velocity → Fresh Air → Exhaust Industrial Measurement Surface Temperature → Equipment Heat Source This is the MTM positioning: Not: “We sell WBGT meters.” But: “Tell us which part of your factory is too hot and when it happens. MTM helps determine what should be measured.” Factory Heat Stress & Workplace Temperature Measurement Solutions Malaysia MTM Precision supports: Manufacturing plants Production areas Warehouses Boiler rooms Kitchens and food processing Loading bays Workshops Outdoor work areas EHS departments Safety officers Facility managers with measurement solutions covering: Temperature Humidity WBGT Heat Stress Air Velocity Ventilation Surface Temperature Data Logging Environmental Monitoring MTM's value is not: “Which temperature meter would you like?” It is: “Tell us where workers feel hot, when it happens and what process is operating. MTM helps determine what should be measured.” Workers Complaining That the Factory Is Too Hot? You do not need to know whether you need a thermometer, WBGT meter, anemometer or data logger. Tell MTM: Which area is hot? What work is being performed? What time is worst? Are hot machines, ovens, boilers or steam involved? Is ventilation installed? Do you need troubleshooting, heat-stress measurement or continuous monitoring? We can help identify suitable measurement options for the problem. MTM Precision Sdn Bhd Showroom & Service Centre No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Website: www.mtmpre.com.my Don't start with the thermometer. Start with where and when the heat problem happens. Tell MTM the factory problem we'll help you determine what needs to be measured.

21 Aug 2026