How to Use Azovtes AE-UT & AE-BUT Temperature Data Logger Malaysia
How to Use Azovtes AE-UT & AE-BUT Temperature Data Logger Malaysia
The Azovtes AE-UT and AE-BUT are disposable temperature data loggers designed for temperature monitoring during transportation and cold-chain applications.
They can be used for food, seafood, pharmaceutical products, fresh produce and other temperature-sensitive shipments.
Although the basic concept is simple — activate the logger, place it with the shipment and review the recorded data at the destination — correct preparation and placement are important for obtaining useful temperature records.
This guide explains the general workflow.
Step 1: Understand What You Need to Monitor
Before activating the logger, determine the objective of the monitoring.
Ask:
What product is being transported?
What temperature conditions are required?
How long will the journey take?
How frequently should temperature be recorded?
Where should the logger be positioned?
Does the customer have specific monitoring requirements?
Do not select temperature limits simply because they are commonly used for another product.
The correct requirements should follow the specifications for the goods being transported.
Step 2: Check the Logger Before Shipment
Before placing the logger inside the shipment, inspect it.
Check that:
The correct model has been selected
The logger is physically undamaged
The shipment details are correct
Required configuration has been completed
The device is ready before loading begins
This should be done before the cargo leaves the facility.
Step 3: Configure the Required Recording Parameters
The logger should be configured according to the monitoring requirement.
Depending on the available settings and workflow, parameters may include:
Recording interval
Start delay
Temperature alarm limits
Recording duration
Other logger settings
A shorter recording interval provides more frequent readings but generates more data.
A longer interval reduces the number of readings.
Choose an interval that makes sense for the duration and sensitivity of the shipment.
Step 4: Identify the Shipment
For businesses handling multiple deliveries, it is useful to associate the logger with a specific shipment.
Record information such as:
Shipment number
Customer
Product
Date
Vehicle number
Container number
Logger identification
Loading time
Destination
This makes it easier to match the recorded data with the correct shipment later.
Step 5: Activate the Logger
Activate the logger according to the manufacturer's operating procedure before or at the required monitoring start point.
Do not simply place an inactive logger into the shipment.
Before closing the package or container, verify that the logger has entered the intended operating state according to the device indications and instructions.
Step 6: Place the Logger at an Appropriate Location
Logger placement is extremely important.
The logger records temperature at its own monitoring location.
It does not automatically represent every point inside a truck, pallet or reefer container.
Possible locations include:
Inside a selected carton
With selected products
Between cartons
Between pallets
Near the centre of the load
Near the rear of a refrigerated truck
At selected points inside a reefer shipment
The correct position depends on what you are trying to monitor.
Step 7: Consider Multiple Loggers for Large Shipments
One logger may be suitable for a small shipment.
A large refrigerated truck or reefer container is different.
Temperature conditions can vary because of:
Airflow
Cargo arrangement
Distance from the refrigeration unit
Door opening
Pallet configuration
Loading density
For important or high-value shipments, multiple monitoring points may provide more representative information.
For example:
Front → Middle → Rear
or
Pallet A → Pallet B → Pallet C
The exact monitoring plan should follow the company's requirements.
Step 8: Send the Logger with the Shipment
Once activated and correctly positioned, the logger travels together with the cargo.
This is one of the major advantages of a disposable temperature data logger.
The logger can accompany the shipment through:
Loading → Truck → Warehouse → Port / Airport → Reefer Container → Destination → Receiving
This creates a temperature history covering the monitored portion of the journey.
Step 9: Retrieve the Logger at the Destination
The receiving party should locate the logger when the shipment arrives.
It is helpful to tell the customer in advance:
That a logger is included
Where it is located
How it should be handled
Who should review the data
Clear instructions reduce the risk of the logger being discarded with packaging before the information is retrieved.
Step 10: Access AE-UT Data
The Azovtes AE-UT uses a USB-based data-access workflow.
After the shipment reaches its destination, the logger can be connected as specified by the manufacturer so that the recorded information can be reviewed.
This makes AE-UT suitable when the receiving process is primarily computer-based.
Step 11: Access AE-BUT Data
The Azovtes AE-BUT provides USB plus Bluetooth connectivity.
Bluetooth provides an additional option for compatible mobile access.
This can be convenient for:
Warehouse personnel
Receiving teams
QA staff
Logistics coordinators
Field personnel
Always follow the manufacturer's instructions for the applicable software or application.
Step 12: Review the Entire Temperature History
Do not look only at the highest or lowest number.
Review the complete timeline.
Look for:
Stable periods
Sudden temperature changes
Gradual temperature increases
Repeated fluctuations
Extended excursions
Recovery periods
The shape of the temperature history can sometimes provide useful clues about what happened during transportation.
Step 13: Compare Temperature Changes with Shipment Events
If an unusual temperature event appears, compare its time with the logistics timeline.
For example:
8:00 AM — Loading
8:30 AM — Truck departure
11:15 AM — Delivery stop
11:30 AM — Temperature increase
12:10 PM — Temperature recovery
2:00 PM — Final delivery
This information may help the company investigate whether the change coincided with loading, door opening, delays or another event.
Step 14: Save the Temperature Record
Businesses may want to retain the recorded information according to their internal quality procedures.
Records can be useful for:
QA documentation
Customer reports
Shipment records
Internal investigation
Supplier evaluation
Logistics review
Process improvement
The retention period should follow the company's own requirements and any applicable procedures.
Common Mistake 1: Starting the Logger Too Late
If the logger is activated only after the cargo is already inside the truck, an important part of the loading process may not be recorded.
Decide beforehand when monitoring should begin.
Common Mistake 2: Poor Logger Placement
A logger positioned directly against an unusual heat or cold source may record conditions that do not represent the intended monitoring location.
Placement should reflect the purpose of the monitoring.
Common Mistake 3: Using Only One Logger for a Large Load
A single reading location may not represent an entire reefer container.
For large or valuable shipments, consider whether several monitoring points are necessary.
Common Mistake 4: Losing the Logger at the Destination
A disposable logger can easily be mistaken for packaging material.
Make sure the receiving customer knows that a temperature logger is inside the shipment.
Common Mistake 5: Assuming the Logger Decides Product Acceptance
A data logger provides temperature records.
It does not automatically determine whether food, pharmaceutical products or other goods should be accepted or rejected.
Product acceptance decisions should follow the relevant product specifications and quality procedures.
AE-UT or AE-BUT?
Choose Azovtes AE-UT when:
Disposable monitoring is required
USB data access is sufficient
A straightforward shipment workflow is preferred
Choose Azovtes AE-BUT when:
Disposable monitoring is required
Bluetooth connectivity is useful
Compatible mobile access is preferred
Receiving teams want additional data-access convenience
Applications in Malaysia
Azovtes disposable temperature data loggers can be considered for suitable applications involving:
Cold-chain logistics
Frozen food
Chilled food
Seafood
Pharmaceutical products
Fresh fruits and vegetables
Refrigerated transportation
Reefer containers
Import and export shipments
Need Help Setting Up Your Temperature Monitoring?
If you are unsure about the appropriate logger, recording interval or number of monitoring points, start by explaining the application.
Tell MTM Precision:
Product: What are you transporting?
Temperature: What conditions are required?
Duration: How long is the shipment?
Transport: Truck, air freight or reefer container?
Quantity: How many cartons or pallets?
Data access: USB or Bluetooth?
We can help you evaluate a suitable temperature data logging solution.
Contact MTM Precision
MTM Precision Sdn Bhd
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com