Sound Level Meter vs Noise Dosimeter for Factory Safety Malaysia
Meta Description: Compare sound level meters and personal noise dosimeters for factory noise monitoring in Malaysia. Learn which instrument is suitable for machinery checks, area surveys and employee exposure assessment.
Sound Level Meter vs Noise Dosimeter for Factory Safety Malaysia
Factory noise may vary according to the machine, production process, distance, operating load and time spent in the area.
A high sound level beside one machine does not automatically represent an employee’s total daily exposure. Similarly, a personal noise-dose result may show excessive exposure without immediately identifying which machine is causing the problem.
This is why factory safety teams may require both a sound level meter and a personal noise dosimeter.
What Is a Sound Level Meter?
A sound level meter measures the sound pressure level at a particular location and time.
It is commonly used to:
-
Measure noise around machinery
-
Compare different production areas
-
Locate major noise sources
-
Check noise before and after maintenance
-
Evaluate engineering controls
-
Create a basic factory noise map
-
Investigate worker complaints
-
Compare equipment under different loads
-
Check whether a new machine has increased area noise
The instrument is normally held or positioned at the required measurement point.
A sound level meter mainly answers:
“How loud is this location or machine right now?”
What Is a Noise Dosimeter?
A noise dosimeter is worn by an employee during the work period. It measures changing noise exposure while the person moves between different locations and performs different tasks.
It is suitable for:
-
Employees working in several factory zones
-
Maintenance technicians with changing duties
-
Forklift drivers
-
Production operators
-
Workers exposed to intermittent high noise
-
Employees working near multiple machines
-
Full-shift personal exposure monitoring
-
Comparing different job groups
A noise dosimeter mainly answers:
“How much noise has this worker received over the monitoring period?”
Sound Level Meter vs Noise Dosimeter
Use a Sound Level Meter When:
-
The noise source must be located
-
Machinery must be compared
-
A factory noise map is required
-
Maintenance results need to be checked
-
Noise at a fixed location is being investigated
-
Engineering controls are being evaluated
-
A quick area survey is required
Use a Noise Dosimeter When:
-
Employee exposure changes throughout the shift
-
The worker moves between several locations
-
Noise is intermittent
-
Personal daily exposure must be assessed
-
Different job groups must be compared
-
A fixed-position reading cannot represent the worker’s activities
The instruments are complementary rather than interchangeable.
Practical Factory Example
Consider a maintenance technician who spends the day working in:
-
A compressor room
-
A production line
-
A quieter workshop
-
A generator area
-
An office
-
A pump room
A sound level meter can measure each area and identify which equipment produces the highest noise.
However, the technician’s daily exposure depends on how long the person remains in each area. A dosimeter worn throughout the work period provides a more representative personal exposure record.
The sound level meter identifies the likely source. The dosimeter evaluates the employee’s accumulated exposure.
Landtek SL-5868P Sound Level Meter
The Landtek SL-5868P is a professional sound level meter suitable for industrial noise measurement and factory inspection applications.
It may be used for:
-
Machinery-noise checks
-
Production-area surveys
-
Workshop noise measurements
-
Comparison before and after maintenance
-
Investigation of abnormal equipment noise
-
Basic environmental and occupational-noise screening
Before purchasing, confirm that the instrument’s measurement range, frequency weighting, time weighting, data functions and performance class match the intended application.
A general sound level meter used for maintenance screening should not automatically be presented as a replacement for the equipment and procedures required in a formal occupational noise risk assessment.
Why Smartphone Apps Are Not Enough
A smartphone application may indicate that an area is loud, but its results can vary according to:
-
Phone microphone design
-
Protective case
-
Automatic gain control
-
Application settings
-
Device orientation
-
Frequency response
-
Lack of acoustic calibration
-
Maximum level limitations
A phone can help create awareness, but it should not replace a suitable sound level meter for industrial measurements or workplace-noise decisions.
Important Noise Measurement Settings
When choosing or using a noise instrument, consider:
Frequency Weighting
A-weighting, displayed as dB(A), is commonly used for many occupational-noise measurements because it approximates the response of human hearing.
C-weighting, displayed as dB(C), may be relevant for peak sound and noise containing stronger low-frequency components.
Time Weighting
Common settings include:
-
Fast
-
Slow
-
Impulse, where supported
The selected time weighting affects how quickly the displayed reading responds to changing noise.
Maximum and Peak Levels
A maximum reading and a peak sound-pressure reading are not necessarily the same. The instrument must support the required measurement function.
Equivalent Continuous Level
An integrating sound level meter may calculate an equivalent continuous sound level over a selected period. This is different from observing only an instantaneous display.
How to Conduct a Basic Factory Noise Survey
A practical preliminary survey may include:
-
List the main machines and noisy processes.
-
Measure the background noise before production starts.
-
Check each machine during normal operation.
-
Measure near the worker’s typical position.
-
Record the distance from the noise source.
-
Note the machine load and operating condition.
-
Check adjacent work areas.
-
Identify intermittent or impact-noise events.
-
Compare readings before and after maintenance.
-
Mark high-noise areas for further assessment.
The record should include the date, time, location, activity, instrument settings and operating condition.
Why Maintenance Can Reduce Factory Noise
An abnormal increase in noise may indicate:
-
Worn bearings
-
Misalignment
-
Loose guards
-
Poor lubrication
-
Damaged gears
-
Air leakage
-
Cavitation
-
Unbalanced fans
-
Loose foundations
-
Excessive vibration
Noise measurement can therefore support both workplace safety and preventive maintenance.
If a machine becomes louder than its normal baseline, the maintenance team can investigate before the condition worsens.
Noise-Control Verification
A sound level meter can help compare conditions before and after:
-
Installing an acoustic enclosure
-
Adding a barrier
-
Repairing a machine
-
Replacing worn bearings
-
Improving lubrication
-
Reducing compressed-air leakage
-
Isolating vibration
-
Changing equipment speed
-
Relocating a noisy process
-
Improving operator distance
Measurements should be taken under comparable operating conditions. A lower reading after maintenance is meaningful only if machine load, distance and measurement settings are similar.
Malaysia Workplace Noise Requirements
Malaysia’s Occupational Safety and Health (Noise Exposure) Regulations 2019 replaced the former 1989 factory noise regulations and came into force on 1 June 2019.
DOSH defines excessive noise using several criteria, including daily noise exposure, personal noise dose, maximum sound pressure and peak sound pressure. The official overview is available from DOSH Malaysia.
Where a formal noise risk assessment is required, the employer should appoint a registered Noise Risk Assessor. DOSH describes the assessor’s responsibilities as including the assessment, report preparation and noise-control recommendations.
Routine measurements taken by a factory maintenance team can help identify possible problems, but they do not automatically replace a formal assessment by the appropriate competent person.
Common Factory Noise-Monitoring Mistakes
Measuring Only Beside the Machine
This identifies source noise but may not represent employee exposure.
Measuring Only Once
Noise may change with load, production speed and operating cycle.
Holding the Meter Too Close to the Body
Reflections from the user’s body may affect the reading.
Ignoring Measurement Distance
Readings taken at different distances cannot be compared properly without recording the measurement position.
Using a Sound Level Meter Instead of a Dosimeter
A fixed-point measurement may not represent a worker who moves throughout the shift.
Using a Dosimeter to Locate the Machine
A personal dose result shows accumulated exposure but may not identify which source contributed the most unless activities and times are also recorded.
Changing Instrument Settings
Results measured with different weighting or response settings may not be directly comparable.
Which Instrument Should a Factory Buy?
Choose a sound level meter first when the main objective is:
-
Maintenance inspection
-
Locating loud machinery
-
Comparing factory zones
-
Checking noise-control improvements
-
Conducting routine safety screening
Choose a noise dosimeter when the main objective is:
-
Measuring personal exposure
-
Monitoring mobile workers
-
Assessing a full work shift
-
Comparing employee groups
-
Capturing changing noise throughout the day
For a complete occupational-noise programme, factories may require both instruments together with a competent noise risk assessment.
Questions to Ask Before Buying
Before selecting an instrument, determine:
-
Is the goal area measurement or personal exposure?
-
Does the employee remain at one workstation?
-
Is the noise continuous, intermittent or impulsive?
-
Is data logging required?
-
Which frequency and time weightings are needed?
-
Is an integrating measurement function required?
-
What instrument performance class is required?
-
Will the results support maintenance screening or formal assessment?
These questions help prevent a basic sound meter from being purchased for an application that requires a personal dosimeter or more specialised measurement system.
Factory Noise Meter Supplier Malaysia
MTM Precision supplies sound level meters and industrial noise-measurement instruments for factories, workshops, machinery inspection and workplace-safety applications in Malaysia.
Contact MTM Precision with details of the measurement objective, expected noise level and whether area or personal monitoring is required.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
01 Sep 2026