1310nm vs 1550nm Fibre Testing: Which NOVKER NK281 Wavelength Should You Use? Malaysia
The NOVKER NK281 Stable Light Source is available with different optical wavelength configurations. For single-mode fibre testing, two of the most commonly used wavelengths are 1310nm and 1550nm.
These wavelengths travel through the same fibre but do not always produce identical loss readings. Understanding their differences helps technicians select the correct NK281 configuration and recognise potential fibre-cabling problems.
What Are 1310nm and 1550nm?
The values 1310nm and 1550nm describe the wavelength of the optical signal transmitted through the fibre.
Single-mode fibre networks commonly operate within these wavelength regions because they provide favourable transmission characteristics.
A stable light source generates the selected optical signal. An optical power meter at the opposite end measures the received power and helps calculate the total link loss.
For accurate testing, the NK281 and optical power meter must be set to the same wavelength.
Why Is 1310nm Commonly Used?
The 1310nm wavelength is widely used for single-mode fibre installation and maintenance.
It is suitable for:
-
FTTH fibre links
-
Building-to-building fibre
-
Campus networks
-
Telecom access networks
-
Factory network backbones
-
General single-mode fibre acceptance testing
At 1310nm, standard single-mode fibre normally provides suitable attenuation performance and relatively low chromatic dispersion.
For contractors requiring a basic single-mode fibre test kit, 1310nm is one of the essential wavelengths.
Why Is 1550nm Important?
The 1550nm wavelength is also widely used in long-distance and telecom fibre networks.
Compared with 1310nm, standard single-mode fibre generally has lower attenuation per kilometre at 1550nm. This makes it useful for longer transmission distances.
However, 1550nm is more sensitive to bending-related loss. A fibre that has been bent too tightly may show a more noticeable loss increase at 1550nm than at 1310nm.
This characteristic makes dual-wavelength testing useful for identifying installation problems that might not be obvious from a 1310nm result alone.
1310nm vs 1550nm: Main Differences
1310nm
-
Commonly used for standard single-mode testing
-
Suitable for short and medium fibre links
-
Less sensitive to some bending conditions
-
Important for FTTH and access-network testing
-
Often used as the first testing wavelength
1550nm
-
Lower fibre attenuation over long distances
-
Common in telecom transmission systems
-
More sensitive to macro-bending loss
-
Useful for detecting tight bends and poor cable routing
-
Recommended as the second wavelength in a complete single-mode test
Why Test at Both Wavelengths?
Testing at only one wavelength may not provide the complete picture.
For example, a fibre link may produce:
-
1310nm loss: 1.8dB
-
1550nm loss: 3.7dB
The unusually large difference may indicate a tight bend, crushed cable section or poor cable management.
If both readings are consistent with the calculated loss budget, the link is more likely to be operating normally.
Dual-wavelength testing provides a stronger basis for installation acceptance and troubleshooting.
How to Test with the NOVKER NK281
The NK281 must be used with a compatible optical power meter.
Step 1: Check the configuration
Confirm that the NK281 supports both 1310nm and 1550nm. Different configurations may provide different wavelengths.
Step 2: Clean the connectors
Clean the NK281 output connector, optical power meter connector and reference patch cords.
Dirt can create additional loss and make the comparison unreliable.
Step 3: Establish a 1310nm reference
Set the NK281 and power meter to 1310nm. Connect them using a suitable reference patch cord and establish the reference value.
Step 4: Test the installed link
Connect the fibre link under test and record the 1310nm loss result.
Step 5: Establish a 1550nm reference
Change both instruments to 1550nm. Establish the reference again if required by the test procedure.
Step 6: Record the second result
Measure and record the 1550nm loss. Compare both readings with the expected link-loss budget.
Do Not Mix the Wavelength Settings
The transmitted and measured wavelengths must match.
Incorrect example:
-
NK281 output: 1310nm
-
Optical power meter setting: 1550nm
Correct example:
-
NK281 output: 1310nm
-
Optical power meter setting: 1310nm
The optical power meter applies wavelength-dependent calibration. Selecting the wrong wavelength can produce an inaccurate reading even when optical power is present.
What Causes High Loss at Both Wavelengths?
If the loss is high at both 1310nm and 1550nm, possible causes include:
-
Dirty connectors
-
Damaged patch cords
-
Poor fusion splices
-
Faulty mechanical splices
-
Excessive connector loss
-
Long fibre distance
-
Incorrect reference procedure
-
Damaged fibre cable
-
Wrong fibre core
-
Poorly seated adaptors
Clean and reconnect all accessible test points before deciding that the installed cable is defective.
An OTDR can then be used to locate the high-loss event.
What Causes Higher Loss at 1550nm?
When the 1550nm result is significantly worse than the 1310nm result, inspect for:
-
Tight fibre bends
-
Cable trapped behind equipment
-
Patch cords bent below their minimum radius
-
Overtightened cable ties
-
Fibre squeezed inside a distribution box
-
Poor cable routing around cabinet corners
-
Damaged or crushed cable sections
These conditions may create greater attenuation at longer wavelengths.
The exact difference that is acceptable depends on the link design, fibre type and project specification.
Is 1490nm Also Required?
The 1490nm wavelength is associated with downstream transmission in many PON systems.
However, the correct instrument depends on the testing objective. A standard stable-light-source loss test is different from measuring live upstream and downstream PON signals.
When testing an active PON network, a suitable PON optical power meter may be required to measure the relevant wavelengths separately without disrupting service.
Therefore:
-
Use NK281 plus a standard power meter for controlled end-to-end loss testing.
-
Use a PON power meter when measuring live PON transmission levels.
-
Confirm the project and network requirements before choosing the wavelength configuration.
Is 1625nm Necessary?
The 1625nm wavelength is often associated with fibre maintenance and out-of-band testing.
It may be useful for specialised telecom applications, but many general FTTH and building-network contractors primarily require 1310nm and 1550nm.
Do not pay for additional wavelengths unless they support the customer’s actual testing work.
Recommended Configuration for General Contractors
For most contractors testing standard single-mode fibre, a 1310/1550nm dual-wavelength NK281 is likely to offer the best balance between practical coverage and cost.
Consider additional wavelengths when:
-
The customer works with specialised telecom systems.
-
The project specifies particular test wavelengths.
-
Multimode fibre must also be tested.
-
The unit will be used for several types of fibre network.
-
Four-wavelength capability is genuinely required.
Single-Mode and Multimode Are Different
The 1310nm and 1550nm combination is primarily associated with single-mode fibre testing.
Multimode fibre commonly uses:
-
850nm
-
1300nm
Before purchasing the NK281, identify the fibre type. A single-mode-only configuration is not the correct choice for a contractor who regularly needs to certify multimode links.
Should You Choose NK281 or NK301?
Choose the NK281 when you want:
-
A practical field-testing instrument
-
Single-mode fibre-loss testing
-
Additional RJ45 network-cable functions
-
One device for mixed fibre and copper-network work
Consider the NK301 when you need:
-
A dedicated professional light source
-
A particular single-mode and multimode combination
-
Up to four integrated optical wavelengths
-
Longer continuous operating time
The final decision should be based on the required wavelength configuration, not merely the model number.