Correct total station setup is one of the most important parts of accurate surveying.
Even when using a high-quality total station, errors in tripod positioning, centering, levelling, instrument height or backsight setup can affect the final survey results.
This step-by-step guide explains how to set up a total station correctly for surveying and construction work in Malaysia.
Step 1: Select a Stable Survey Point
Before setting up the instrument, identify the correct control point or survey station.
The location should provide:
Stable ground
Good visibility to required survey points
Sufficient working space around the instrument
Minimal obstruction between the total station and targets
Avoid unstable ground where the tripod legs may move or sink during measurement.
Step 2: Set Up the Tripod
Open the tripod legs and position the tripod approximately over the survey point.
Adjust the legs so that the tripod head is reasonably level and at a comfortable working height.
Push the tripod feet firmly into the ground where appropriate.
The tripod must remain stable throughout the survey.
A small movement at the tripod can affect the position of the instrument.
Step 3: Mount the Total Station
Carefully remove the total station from its carrying case.
Place it onto the tripod head and secure it using the tripod fixing screw.
Before releasing your hand from the instrument, make sure it is properly attached.
Never leave a total station unsecured on a tripod.
Step 4: Centre the Total Station Over the Survey Point
The instrument should be positioned directly above the required survey point.
Depending on the total station, centering may be performed using an:
Optical plummet
Laser plummet
Look through the optical plummet or activate the laser plummet and check the position relative to the ground mark.
Adjust the tripod or tribrach position until the instrument is approximately centred.
Step 5: Perform Rough Levelling
Adjust the tripod legs to bring the circular bubble approximately into the centre.
This is the rough levelling stage.
Getting reasonably close using the tripod legs makes the next fine-levelling process easier.
Step 6: Fine-Level Using the Levelling Screws
The levelling screws at the base of the total station are used for precise levelling.
A common method is to align the instrument with two levelling screws and adjust them together while observing the level.
Then rotate the instrument and use the third screw to complete the adjustment.
Modern total stations may also provide an electronic level on the display.
Continue adjusting until the instrument indicates that it is correctly levelled.
Step 7: Recheck the Centering
This step is frequently overlooked.
After levelling the total station, check the optical or laser plummet again.
Levelling adjustments can slightly change the instrument's position over the ground point.
If the instrument is no longer centred, carefully correct the position and then check the level again.
You may need to repeat:
Centre → Level → Recheck Centre → Recheck Level
until both are correct.
Step 8: Measure the Instrument Height
Measure the instrument height according to the procedure specified for your total station and survey workflow.
Enter the correct value into the instrument.
An incorrect instrument height can produce incorrect elevation results.
Do not estimate the height when accurate survey work is required.
Step 9: Set Up the Prism
Position the prism accurately over the required backsight or survey point.
Check that the prism pole is vertical.
Enter the correct prism height into the total station when required.
Also make sure the correct prism constant is selected.
Using the wrong prism constant can introduce a systematic error into distance measurements.
Step 10: Enter the Station Coordinates
If working from known coordinates, enter the coordinates of the occupied station.
Depending on the system used, this may include:
Easting
Northing
Elevation
Always verify the numbers before continuing.
A simple data-entry error can affect every subsequent coordinate measured from that setup.
Step 11: Establish the Backsight
Aim the telescope toward the known backsight or reference point.
Use the horizontal and vertical controls to aim accurately at the prism or target.
The backsight establishes the orientation of the total station.
Incorrect backsight setup is one of the most serious field mistakes because subsequent points can appear internally consistent while still being positioned incorrectly.
Step 12: Check Before Starting the Survey
Before collecting large amounts of data or beginning important setting-out work, perform a verification measurement.
Where possible, measure another known point and compare the result with its expected coordinates or distance.
This provides a quick check that the setup is reasonable.
Total Station Setup Checklist
Before beginning work, check:
Tripod is stable
Total station is securely mounted
Instrument is centred
Instrument is level
Centering has been rechecked after levelling
Instrument height is correct
Prism height is correct
Correct prism constant is selected
Station coordinates are correct
Backsight coordinates are correct
Backsight orientation is verified
Battery has sufficient charge
A two-minute check can prevent hours of incorrect fieldwork.
Common Total Station Setup Mistakes
Poor Tripod Stability
If a tripod leg moves during surveying, the instrument position may change.
This can affect measurements taken after the movement.
Instrument Not Exactly Centred
Small centering errors may become important in precision surveying and short-distance angular work.
Incorrect Levelling
The total station's compensator can correct only within its designed operating range.
It should not be treated as a substitute for proper instrument levelling.
Wrong Instrument Height
Entering the wrong instrument height affects calculated elevations.
Wrong Prism Height
Incorrect prism height can also produce elevation errors.
Wrong Prism Constant
Different prism systems may use different prism constants.
Always confirm that the instrument setting matches the prism being used.
Incorrect Backsight
An incorrect backsight can rotate the orientation of the survey and affect subsequent setting-out or coordinate measurements.
Why Does My Total Station Keep Going Out of Level?
If the instrument repeatedly goes out of level even after careful setup, check:
Tripod stability
Tripod head
Tribrach
Levelling screws
Ground condition
Instrument mounting
If the physical setup is stable but the problem continues, the total station may require professional inspection.
Should You Check Calibration Before Important Survey Work?
For accuracy-critical work, the condition of the total station should be considered before starting the project.
Calibration checks can help verify important systems such as:
Horizontal angle measurement
Vertical angle measurement
EDM distance measurement
Compensator
Optical or laser plummet
Telescope alignment
Levelling system
A total station should also be inspected if it has been dropped, suffered a significant impact or begins producing unusual measurements.
Total Station Calibration & Repair Malaysia
MTM Precision supports professional surveyors, contractors and engineering companies with total station calibration, servicing and repair in Malaysia.
If your total station:
Cannot maintain level
Produces inconsistent coordinates
Shows unusual angle readings
Gives inconsistent distance measurements
Has centering problems
Has been dropped or knocked
Has not been calibrated for an extended period
professional inspection is recommended before using it for critical surveying work.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
06 Sep 2026