How to Set Up a Total Station Correctly Step by Step Malaysia

How to Set Up a Total Station Correctly Step by Step Malaysia

 

Correct total station setup is one of the most important parts of accurate surveying.

 

Even when using a high-quality total station, errors in tripod positioning, centering, levelling, instrument height or backsight setup can affect the final survey results.

 

This step-by-step guide explains how to set up a total station correctly for surveying and construction work in Malaysia.

 

Step 1: Select a Stable Survey Point

 

Before setting up the instrument, identify the correct control point or survey station.

 

The location should provide:

 

Stable ground

 

Good visibility to required survey points

 

Sufficient working space around the instrument

 

Minimal obstruction between the total station and targets

 

Avoid unstable ground where the tripod legs may move or sink during measurement.

 

Step 2: Set Up the Tripod

 

Open the tripod legs and position the tripod approximately over the survey point.

 

Adjust the legs so that the tripod head is reasonably level and at a comfortable working height.

 

Push the tripod feet firmly into the ground where appropriate.

 

The tripod must remain stable throughout the survey.

 

A small movement at the tripod can affect the position of the instrument.

 

Step 3: Mount the Total Station

 

Carefully remove the total station from its carrying case.

 

Place it onto the tripod head and secure it using the tripod fixing screw.

 

Before releasing your hand from the instrument, make sure it is properly attached.

 

Never leave a total station unsecured on a tripod.

 

Step 4: Centre the Total Station Over the Survey Point

 

The instrument should be positioned directly above the required survey point.

 

Depending on the total station, centering may be performed using an:

 

Optical plummet

 

Laser plummet

 

Look through the optical plummet or activate the laser plummet and check the position relative to the ground mark.

 

Adjust the tripod or tribrach position until the instrument is approximately centred.

 

Step 5: Perform Rough Levelling

 

Adjust the tripod legs to bring the circular bubble approximately into the centre.

 

This is the rough levelling stage.

 

Getting reasonably close using the tripod legs makes the next fine-levelling process easier.

 

Step 6: Fine-Level Using the Levelling Screws

 

The levelling screws at the base of the total station are used for precise levelling.

 

A common method is to align the instrument with two levelling screws and adjust them together while observing the level.

 

Then rotate the instrument and use the third screw to complete the adjustment.

 

Modern total stations may also provide an electronic level on the display.

 

Continue adjusting until the instrument indicates that it is correctly levelled.

 

Step 7: Recheck the Centering

 

This step is frequently overlooked.

 

After levelling the total station, check the optical or laser plummet again.

 

Levelling adjustments can slightly change the instrument's position over the ground point.

 

If the instrument is no longer centred, carefully correct the position and then check the level again.

 

You may need to repeat:

 

Centre → Level → Recheck Centre → Recheck Level

 

until both are correct.

 

Step 8: Measure the Instrument Height

 

Measure the instrument height according to the procedure specified for your total station and survey workflow.

 

Enter the correct value into the instrument.

 

An incorrect instrument height can produce incorrect elevation results.

 

Do not estimate the height when accurate survey work is required.

 

Step 9: Set Up the Prism

 

Position the prism accurately over the required backsight or survey point.

 

Check that the prism pole is vertical.

 

Enter the correct prism height into the total station when required.

 

Also make sure the correct prism constant is selected.

 

Using the wrong prism constant can introduce a systematic error into distance measurements.

 

Step 10: Enter the Station Coordinates

 

If working from known coordinates, enter the coordinates of the occupied station.

 

Depending on the system used, this may include:

 

Easting

 

Northing

 

Elevation

 

Always verify the numbers before continuing.

 

A simple data-entry error can affect every subsequent coordinate measured from that setup.

 

Step 11: Establish the Backsight

 

Aim the telescope toward the known backsight or reference point.

 

Use the horizontal and vertical controls to aim accurately at the prism or target.

 

The backsight establishes the orientation of the total station.

 

Incorrect backsight setup is one of the most serious field mistakes because subsequent points can appear internally consistent while still being positioned incorrectly.

 

Step 12: Check Before Starting the Survey

 

Before collecting large amounts of data or beginning important setting-out work, perform a verification measurement.

 

Where possible, measure another known point and compare the result with its expected coordinates or distance.

 

This provides a quick check that the setup is reasonable.

 

Total Station Setup Checklist

 

Before beginning work, check:

 

Tripod is stable

 

Total station is securely mounted

 

Instrument is centred

 

Instrument is level

 

Centering has been rechecked after levelling

 

Instrument height is correct

 

Prism height is correct

 

Correct prism constant is selected

 

Station coordinates are correct

 

Backsight coordinates are correct

 

Backsight orientation is verified

 

Battery has sufficient charge

 

A two-minute check can prevent hours of incorrect fieldwork.

 

Common Total Station Setup Mistakes

 

Poor Tripod Stability

 

If a tripod leg moves during surveying, the instrument position may change.

 

This can affect measurements taken after the movement.

 

Instrument Not Exactly Centred

 

Small centering errors may become important in precision surveying and short-distance angular work.

 

Incorrect Levelling

 

The total station's compensator can correct only within its designed operating range.

 

It should not be treated as a substitute for proper instrument levelling.

 

Wrong Instrument Height

 

Entering the wrong instrument height affects calculated elevations.

 

Wrong Prism Height

 

Incorrect prism height can also produce elevation errors.

 

Wrong Prism Constant

 

Different prism systems may use different prism constants.

 

Always confirm that the instrument setting matches the prism being used.

 

Incorrect Backsight

 

An incorrect backsight can rotate the orientation of the survey and affect subsequent setting-out or coordinate measurements.

 

Why Does My Total Station Keep Going Out of Level?

 

If the instrument repeatedly goes out of level even after careful setup, check:

 

Tripod stability

 

Tripod head

 

Tribrach

 

Levelling screws

 

Ground condition

 

Instrument mounting

 

If the physical setup is stable but the problem continues, the total station may require professional inspection.

 

Should You Check Calibration Before Important Survey Work?

 

For accuracy-critical work, the condition of the total station should be considered before starting the project.

 

Calibration checks can help verify important systems such as:

 

Horizontal angle measurement

 

Vertical angle measurement

 

EDM distance measurement

 

Compensator

 

Optical or laser plummet

 

Telescope alignment

 

Levelling system

 

A total station should also be inspected if it has been dropped, suffered a significant impact or begins producing unusual measurements.

 

Total Station Calibration & Repair Malaysia

 

MTM Precision supports professional surveyors, contractors and engineering companies with total station calibration, servicing and repair in Malaysia.

 

If your total station:

 

Cannot maintain level

 

Produces inconsistent coordinates

 

Shows unusual angle readings

 

Gives inconsistent distance measurements

 

Has centering problems

 

Has been dropped or knocked

 

Has not been calibrated for an extended period

 

professional inspection is recommended before using it for critical surveying work.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


 

06 Sep 2026