How to Level a Total Station Correctly Levelling Screws Guide Malaysia

How to Level a Total Station Correctly – Levelling Screws Guide Malaysia   Correct levelling is one of the most important steps when setting up a total station.   Before measuring angles, distances or coordinates, the instrument must be properly mounted, centred and levelled. Poor levelling can cause setup problems and may reduce the reliability of surveying work.   This guide explains how to use the three levelling screws (foot screws) on a total station and what to check when an instrument is difficult to level.   What Are Total Station Levelling Screws?   Levelling screws are the three adjustable screws located around the base or tribrach of the total station.   Their purpose is to change the inclination of the instrument so that its vertical axis is correctly established.   They work together with the:   Circular level   Electronic level   Tribrach   Compensator   The levelling screws should be adjusted smoothly. Excessive force should not be necessary.   Step 1: Set Up the Tripod   Place the tripod approximately over the survey point.   Spread the tripod legs sufficiently to provide a stable base and adjust the height to a comfortable working position.   Before mounting the total station, try to make the tripod head approximately level.   This reduces the amount of adjustment required later.   Step 2: Mount and Secure the Total Station   Place the total station onto the tripod and secure it correctly.   Always confirm that the instrument is firmly attached before letting go.   A loose connection between the tripod and instrument can cause movement during surveying.   Step 3: Rough-Level With the Tripod Legs   Check the circular bubble.   Instead of immediately making large adjustments with the levelling screws, use the tripod legs to bring the bubble approximately toward the centre.   This is called rough levelling.   Once the bubble is reasonably centred, continue with the levelling screws.   Step 4: Position Two Levelling Screws Parallel to the Display   Rotate the total station so that two levelling screws are approximately parallel to the instrument or your viewing position.   These two screws will be adjusted together.   A useful way to remember the movement is:   Both thumbs move inward or outward together.   Watch the bubble or electronic level while making small adjustments.   Continue until the level is centred in that direction.   Step 5: Rotate the Total Station 90 Degrees   Rotate the instrument approximately 90°.   The third levelling screw can now be used to correct the remaining direction.   Turn the third screw slowly until the bubble or electronic level is centred.   Avoid making unnecessarily large adjustments.   Step 6: Rotate and Check Again   Rotate the total station through different directions and observe the level.   The instrument should remain level as it rotates.   If necessary, repeat the adjustment using the levelling screws until the level remains correctly centred.   Step 7: Recheck Centering Over the Survey Point   Levelling is only part of the setup.   After levelling, check the optical or laser plummet again.   The instrument may have moved slightly away from the survey point during adjustment.   For accurate work, both conditions must be satisfied:   Correctly centred + correctly levelled   If you correct the centering, check the level again afterwards.   What Does the Electronic Level Do?   Many modern total stations provide an electronic level on the display.   This makes fine levelling easier because the operator can see the instrument's inclination electronically.   However, the electronic level does not eliminate the need for proper setup.   The tripod should still be stable and the instrument should be approximately level before fine adjustment.   What Is the Total Station Compensator?   A total station compensator detects small residual instrument tilt and compensates for it within the instrument's specified operating range.   This improves measurement reliability when the total station is very slightly off level.   However:   A compensator is not a replacement for proper levelling.   The surveyor should always level the instrument correctly before starting measurements.   Why Does My Total Station Bubble Move When I Rotate the Instrument?   This is an important troubleshooting sign.   If you carefully level the total station but the level moves significantly when the instrument is rotated, possible causes include:   Incorrect initial levelling   Unstable tripod   Loose tripod connection   Tribrach problem   Levelling screw problem   Circular level requiring adjustment   Electronic level requiring checking   Instrument requiring calibration or servicing   Try setting up the instrument again on firm ground.   If the same problem repeatedly occurs, professional inspection is advisable.   Why Are My Total Station Levelling Screws Too Tight?   Levelling screws should normally operate smoothly.   If one or more screws are unusually tight, difficult to turn or inconsistent in movement, avoid forcing them.   Possible causes can include:   Dirt or contamination   Mechanical wear   Impact damage   Damaged threads   Tribrach problems   Forcing a damaged levelling mechanism may make the problem worse.   Have the tribrach or instrument inspected if the screws cannot be adjusted normally.   Why Are My Levelling Screws Too Loose?   Excessive looseness can also be a problem.   If the levelling mechanism cannot maintain a stable position, the total station may move after setup.   This is especially important during:   Construction setting out   Control surveys   Boundary surveys   Engineering surveys   Precision alignment   A total station should remain stable throughout the measurement process.   Total Station Is Level but Measurements Are Still Wrong   Correct levelling does not guarantee that every other instrument parameter is correct.   If measurements remain inconsistent, check:   Station coordinates   Backsight coordinates   Instrument height   Prism height   Prism constant   Target setup   EDM settings   Telescope alignment   Compensator condition   The total station itself may also require calibration.   When Should a Total Station Be Checked or Calibrated?   Consider professional inspection when:   The level changes significantly during rotation   The instrument cannot be levelled normally   Levelling screws are damaged   The instrument has been dropped   Angle readings appear inconsistent   Distance measurements appear abnormal   The optical or laser plummet appears misaligned   Survey results repeatedly disagree with known control points   Calibration can verify whether important instrument systems remain within the required tolerance.   Total Station Calibration and Repair Malaysia   MTM Precision provides total station calibration, inspection, servicing and repair in Malaysia.   Checks may include relevant instrument functions such as:   Horizontal angle   Vertical angle   EDM distance measurement   Compensator   Telescope alignment   Optical or laser plummet   Levelling system   Tribrach and levelling screws   For surveyors and contractors, maintaining the total station in good condition helps reduce the risk of discovering measurement problems only after setting-out or construction work has already been completed.   Contact MTM Precision   MTM Precision Sdn. Bhd. Showroom & Service Centre No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia   馃寪 Website: www.mtmpre.com.my 馃摟 Email: mtmpre@yahoo.com 馃摫 WhatsApp: +6016-660 7346  

06 Sep 2026