How to Detect Gas Leaks During Factory Maintenance Malaysia
Gas leaks in a factory may occur around pipes, valves, regulators, storage areas, process equipment and utility systems. Some leaks produce a noticeable smell, but others may be invisible, odourless or difficult to recognise before they become dangerous.
A portable gas detector helps maintenance teams identify hazardous atmospheres and investigate possible leak sources. However, the detector must match the target gas and the way the inspection will be performed.
Where Can Gas Leaks Occur in a Factory?
Common inspection points include:
Pipe joints and flanges
Valves and valve stems
Pressure regulators
Flexible hoses
Gas-cylinder connections
Storage tanks
Boiler and burner systems
Refrigeration equipment
Compressors
Chemical-processing equipment
Wastewater areas
Battery-charging rooms
Confined spaces
Gas cabinets and manifolds
Leaks may develop due to worn seals, corrosion, vibration, loose fittings, physical damage or incorrect installation.
Identify the Target Gas First
There is no universal portable detector that is suitable for every gas.
Before selecting an instrument, determine:
Which gas may be leaking
Whether it is combustible, toxic or asphyxiating
Expected concentration
Required measuring range
Possible cross-sensitivities
Whether the work area is classified as hazardous
Whether remote sampling is required
Examples of gases that may be encountered during factory maintenance include:
Methane
LPG
Hydrogen
Carbon monoxide
Hydrogen sulphide
Ammonia
Carbon dioxide
Oxygen deficiency
Refrigerant gases
Volatile organic compounds
A standard four-gas detector usually measures O₂, LEL, CO and H₂S. It should not be assumed to detect ammonia, carbon dioxide, refrigerants or every combustible gas without confirming its sensor configuration.
Gas Leak Detector vs Multi-Gas Detector
These instruments may be used for different purposes.
Gas Leak Detector
A gas leak detector is generally used to investigate and locate a suspected leak around a particular component.
Typical applications include:
Checking pipe connections
Scanning valves and regulators
Inspecting gas appliances
Testing cylinder connections
Tracing leakage around machinery
Checking natural-gas installations
A probe-equipped pump detector can help the technician compare readings at different points and move closer to the suspected source.
Multi-Gas Detector
A multi-gas detector is mainly used to warn workers when the surrounding atmosphere becomes hazardous.
It is suitable for:
Confined-space entry
Factory shutdown work
Wastewater maintenance
Tank cleaning
Boiler-room inspection
Chemical-process areas
Personal gas monitoring
Some pump-type multi-gas detectors can also perform remote sampling before workers enter an area.
Pump-Type or Diffusion-Type for Leak Detection?
For locating a leak, a pump-type detector is generally more practical because it actively draws gas through a probe or tube.
It allows the user to:
Sample from a safer distance
Reach difficult locations
Check inside enclosures
Compare concentrations at multiple points
Test an area before approaching it
A diffusion detector is better suited to personal protection and continuous monitoring around the worker.
For higher-risk maintenance, teams may use a pump-type detector to investigate the area while workers also wear diffusion-type personal detectors.
Practical Gas-Leak Inspection Sequence
Gas-leak work should be carried out by trained personnel under the factory’s safety procedure. A general inspection sequence includes:
1. Review the Process
Identify the gas, equipment, pressure, operating condition and previous leak history.
2. Control the Work Area
Restrict access where necessary. Remove ignition sources when a combustible atmosphere may be present and follow the appropriate emergency or permit procedure.
3. Confirm the Detector Configuration
Check that the installed sensor is designed for the suspected gas and required concentration range.
4. Inspect the Detector
Check:
Sensor openings
Filter
Sampling probe
Tubing
Pump operation
Battery level
Calibration status
5. Perform a Bump Test
Expose the detector to suitable test gas and confirm that the sensors and alarms respond before relying on it.
6. Check the General Atmosphere
Before moving directly toward the suspected source, check whether the surrounding area is already hazardous.
7. Approach Gradually
Move the probe slowly around potential leakage points. Observe changes in readings instead of immediately placing the detector against the equipment.
8. Monitor Continuously
Gas concentration may change with ventilation, equipment operation and maintenance activities. Continue monitoring until the work is completed and the area has been confirmed safe under the site procedure.
Why Does the Reading Increase but Not Identify the Exact Leak?
A gas detector measures the gas reaching its sensor. Air movement can carry gas away from the actual leak point.
Readings may be affected by:
Ventilation fans
Open doors
Wind
Hot surfaces
Equipment movement
Gas density
Probe position
Sampling-tube length
Pump-flow rate
The highest reading does not always sit directly over the damaged component. Technicians may need to approach from different directions and compare multiple points.
Should You Use Soap Solution?
A suitable leak-detection solution may help confirm leakage at certain pressurised pipe joints by producing bubbles. However, it is not appropriate for every gas, surface, pressure or electrical installation.
A gas detector provides atmospheric information and may help locate the general leak area. A leak-detection solution can sometimes help confirm the exact joint.
Users should follow the equipment manufacturer’s instructions and site procedures. Do not apply unsuitable liquid to hot, energised, reactive or sensitive equipment.
Common Gas-Leak Detection Mistakes
Avoid these common mistakes:
Depending only on smell
Using a detector with the wrong sensor
Skipping the bump test
Ignoring an overdue calibration
Blocking the detector’s gas inlet
Moving the probe too quickly
Testing only one side of the equipment
Ignoring ventilation direction
Using a diffusion detector for inaccessible remote points
Entering an enclosed area before atmospheric testing
Continuing work after a gas alarm without following site procedure
Assuming that a zero reading proves there is no hazard
A zero reading may also result from an expired sensor, blocked inlet, unsuitable measuring range or incorrect detector.
What Should You Do When the Detector Alarms?
Treat every alarm according to the factory’s established safety procedure.
Depending on the site and gas involved, necessary actions may include:
Stop work
Warn nearby personnel
Leave the affected area
Prevent unauthorised entry
Eliminate ignition sources where safe and applicable
Isolate the gas supply using approved procedures
Improve ventilation
Inform the safety or emergency-response team
Continue remote monitoring from a safe location
Do not silence the alarm and continue working without identifying the reason for the reading.
Gas Detection for Planned Factory Maintenance
Gas detection should be prepared before shutdown or maintenance work begins.
Planning may include:
Listing the gases used in each production area
Identifying confined spaces
Selecting suitable sensors
Confirming the number of detectors needed
Assigning pump and personal monitors
Scheduling calibration
Preparing bump-test gas and regulators
Charging detector batteries
Inspecting sampling tubes and filters
Recording detector assignments
Preparing spare instruments
Last-minute detector selection increases the risk of receiving an instrument with the wrong gas configuration.
Gas Detector Options from MTM Precision
MTM Precision supplies portable gas detectors for gas-leak investigation, confined-space entry and factory-maintenance applications in Malaysia.
Selected solutions include:
OTYWELL OT131 – pump-type detector for selected gas-leak applications
OTYWELL G40S – portable multi-gas monitoring
OTYWELL G60 – industrial multi-gas configurations
OTYWELL OT135S – pump-type multi-gas configurations
Eranntex MS104K series – professional multi-gas monitoring options
Smart Sensor ST8904 – four-gas detector
Wintact WT8812 – portable multi-gas detector
The exact detector should be selected according to the target gas, measuring range, pump requirement and working environment.
Information Required for a Recommendation
When requesting a quotation, provide:
Target gas
Factory process or equipment
Expected concentration
Leak location or personal-monitoring requirement
Indoor, outdoor or confined-space use
Pump or diffusion preference
Required measuring range
Number of users
Data-recording requirement
Calibration or test-report requirement
Photos of the equipment and a description of the work process may also help identify a suitable detector.
Contact MTM Precision
Contact MTM Precision for gas-leak detectors and multi-gas detectors for factory maintenance, confined spaces and industrial-safety applications in Malaysia.
MTM Precision Sdn Bhd
Website: www.mtmpre.com
Email: mtmpre@yahoo.com
WhatsApp: 016-660 7346
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
14 Sep 2026