Four-Gas Detector for Confined Spaces: O2, LEL, CO and H2S Explained Malaysia

A four-gas detector is commonly used for confined-space entry because it monitors four major atmospheric hazards at the same time: Oxygen (O) Combustible gas (%LEL) Carbon monoxide (CO) Hydrogen sulphide (HS) This combination is widely used for tanks, manholes, sewers, pits, vessels and factory-maintenance work. However, a four-gas detector does not detect every possible hazardous gas. Users must first identify the gases associated with the workplace, process and materials before deciding that a standard four-gas configuration is sufficient. Why Test the Atmosphere Before Entry? A confined space may appear safe while containing an atmosphere that can cause poisoning, unconsciousness, fire or explosion. Possible hazards include: Low oxygen Excess oxygen Combustible gas or vapour Toxic gas Gas released from sludge or residue Process gas entering through connected pipes Fumes generated during maintenance Changing conditions caused by poor ventilation Atmospheric testing should be carried out before entry and continued throughout the work according to the site’s confined-space procedure. What Does the O Sensor Measure? The oxygen sensor measures oxygen concentration as a percentage by volume. Normal fresh air contains approximately 20.9% oxygen. A detector may alarm when oxygen falls below or rises above the approved site limits. Causes of Low Oxygen Oxygen deficiency may be caused by: Nitrogen or inert-gas displacement Rusting and oxidation Combustion Welding Biological decomposition Chemical reactions Poor ventilation Gas release inside an enclosed space A worker may become impaired or unconscious without receiving a clear sensory warning. Causes of High Oxygen Oxygen enrichment may occur due to leaking oxygen equipment or an oxygen-related process. An oxygen-enriched atmosphere can increase the likelihood and severity of combustion. Materials that normally burn slowly may ignite more easily. What Does %LEL Measure? LEL means Lower Explosive Limit. The combustible-gas channel indicates how close the atmosphere is to the concentration at which the gas or vapour can ignite. The reading is normally shown as %LEL. For example, a reading of 10% LEL means that the measured concentration has reached 10% of the lower explosive limit for the gas to which the detector is responding or calibrated. It does not mean the atmosphere contains 10% gas by volume. Possible Sources of Combustible Gas Natural gas LPG Methane Hydrogen Fuel vapour Solvents Process chemicals Decomposition gas Leaking pipes or cylinders Combustible-gas sensors have limitations. Their response may depend on the calibration gas, actual target gas, oxygen level and sensor technology. What Is Carbon Monoxide? span style="color:#000000;">Carbon monoxide is a toxic gas produced by incomplete combustion. Possible factory and maintenance sources include: Engines Generators Boilers Furnaces Burners Welding and hot work Forklifts Fire or smouldering material Poorly ventilated combustion equipment Carbon monoxide cannot be reliably identified by smell, colour or appearance. The CO channel of a four-gas detector is commonly displayed in parts per million (ppm). What Is Hydrogen Sulphide? Hydrogen sulphide is a highly toxic gas that may be produced by decomposing organic material or certain industrial processes. Possible locations include: Sewers Manholes Wastewater plants Sludge tanks Drainage systems Pulp and paper facilities Oil and gas operations Chemical processes HS may have a recognisable odour at low concentrations, but smell should never be used as a safety test. The ability to notice the odour can quickly become unreliable. The HS reading is normally displayed in ppm. In What Order Should the Atmosphere Be Tested? Testing procedures commonly consider: Oxygen concentration Combustible atmosphere Toxic gases This order is important because some combustible-gas sensor technologies require sufficient oxygen to operate correctly. The actual procedure, acceptance criteria and alarm limits must follow the site risk assessment, detector instructions and applicable Malaysian safety requirements. Why Test at Different Levels? Gases and vapours may collect at different heights depending on their density, temperature, source and ventilation. A confined space should not be represented by a single reading taken only at the opening. Where appropriate, test: Upper level Middle level Lower level Areas with poor ventilation Around suspected gas sources Near connected pipelines or process openings A pump-type detector with suitable sampling tubing can be used for remote testing before entry. Allow enough time for the sample to travel through the tube and for the sensor readings to stabilise at each level. Pump-Type vs Diffusion Four-Gas Detector Pump-Type Four-Gas Detector A pump-type model actively draws air through a probe or sampling tube. It is suitable for: Pre-entry atmospheric testing Sampling tanks and manholes Checking multiple depths Remote area inspection Testing enclosed equipment Diffusion Four-Gas Detector A diffusion model monitors the atmosphere immediately surrounding the instrument. It is commonly used for: Personal worker protection Continuous monitoring after entry Factory-maintenance patrols Wastewater operations Routine industrial-safety work Forconfined-space work, a pump detector may be used for pre-entry testing while workers wear diffusion detectors during entry. Does a Four-Gas Detector Detect CO? Normally, a standard O, LEL, CO and HS detector does not measure carbon dioxide. CO and CO are different gases and require different sensors. Applications involving fermentation, laboratories, food processing, dry ice, beverage production, inert-gas systems or certain confined spaces may require a dedicated CO sensor. Selected models such as the OTYWELL OT135S can be configured with CO together with other required gases. The exact sensor combination must be confirmed before ordering. Does It Detect Ammonia or Sulphur Dioxide? Not unless the detector contains the corresponding sensors. A standard four-gas detector should not be expected to detect: Ammonia Sulphur dioxide Chlorine Nitrogen dioxide Phosphine Refrigerant gases VOCs Every combustible or toxic gas OTYWELL and Eranntex offer selected multi-gas configurations for customers who require application-specific sensors. Checks Required Before Use Before using a four-gas detector: Inspect the housing and sensor openings Check the pump, tube and filter where applicable Confirm the installed gases Review the calibration status Switch on the detector in clean air Allow the self-test and warm-up to finish Perform the required bump test Confirm audible, visual and vibration alarms Check the battery capacity Record the pre-use inspection A normal display or zero reading does not prove that all sensors are functioning. What Should Happen If the Detector Alarms? When any channel alarms: Stop work Follow the site emergency procedure Leave or avoid the affected area Warn nearby personnel Inform the responsible supervisor Investigate only from a safe location Do not reset the alarm and continue without identifying the cause The detector’s alarm levels should only be configured by authorised personnel according to the organisation’s safety requirements. Four-Gas and Multi-Gas Detector Options MTM Precision supplies portable gas detectors for confined spaces, factory maintenance and industrial-safety applications in Malaysia. Selected options include: OTYWELL G40S OTYWELL G60 OTYWELL OT135S Eranntex MS104K-S1 Eranntex MS104K-S2 Smart Sensor ST8904 Wintact WT8812 Standard four-gas models are suitable for selected O, LEL, CO and HS applications. OTYWELL and Eranntex options can support customers requiring pump sampling, additional gases or more specialised configurations. Information Required for Model Selection When requesting a quotation, provide: Type of confined space Industry and process Target gases Required measuring ranges Pump or diffusion requirement Sampling-tube length Number of workers Data-logging requirement Alarm-setting requirement Calibration or test-report requirement MTM Precision can then recommend whether a standard four-gas detector is sufficient or a customised multi-gas configuration is required. Contact MTM Precision Contact MTM Precision for four-gas and multi-gas detectors for confined spaces, wastewater facilities, factories and maintenance teams in Malaysia. MTM Precision Sdn Bhd Website: www.mtmpre.com Email: mtmpre@yahoo.com WhatsApp: 016-660 7346 Showroom & Service Centre No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia.

14 Sep 2026