How to Use Eranntex MS104K-M for Confined Space Gas Testing Malaysia
How to Use Eranntex MS104K-M for Confined Space Gas Testing Malaysia
Confined spaces may contain toxic gases, combustible gases or unsafe oxygen levels, even when no unusual smell or visible warning sign is present.
The Eranntex MS104K-M portable 4-in-1 gas detector can be configured to monitor multiple gas hazards and perform atmospheric testing before a worker enters a confined space.
What Is a Confined Space?
Typical confined spaces include:
Storage tanks
Manholes
Sewers and drains
Underground chambers
Process vessels
Silos
Utility tunnels
Pits and trenches
Boilers
Ship compartments
Restricted access, poor ventilation and the possibility of a hazardous atmosphere make these locations dangerous.
Which Gases Should Be Tested?
A common MS104K-M configuration for confined-space work is:
Oxygen (O₂): Detects oxygen deficiency or enrichment
Combustible gas (EX): Indicates fire or explosion risk in %LEL
Carbon monoxide (CO): Detects toxic carbon monoxide exposure
Hydrogen sulphide (H₂S): Detects toxic hydrogen sulphide exposure
This standard four-gas combination is widely used, but it is not suitable for every workplace.
Facilities involving ammonia, carbon dioxide, sulphur dioxide, chlorine, VOCs or other process gases may require a different detector configuration.
A workplace risk assessment should identify the gases that need to be monitored before the instrument is ordered.
Why Pump Sampling Is Important
A worker should not enter a potentially hazardous space simply to obtain the first atmospheric reading.
The MS104K-M supports diffusion monitoring and external pump-suction sampling. By connecting a pump, hose or suitable sampling probe, the operator can draw a gas sample from inside the space while remaining outside.
Pump sampling is useful for:
Pre-entry atmospheric testing
Checking a tank before opening or maintenance
Testing through a manhole opening
Sampling at different depths
Inspecting difficult-to-reach areas
Investigating a suspected gas leak
The sampling hose must be suitable for the target gas and application.
Step 1: Inspect the Detector
Before use, check:
Battery condition
Sensor status
Alarm indicators
Pump and tubing condition
Sampling inlet
Calibration status
Physical condition of the detector
Required accessories
Do not use the instrument if the housing, sampling line or sensor inlet is damaged.
Step 2: Perform the Required Functional Check
A bump test confirms that the sensors respond to gas and that the audible, visual and vibration alarms operate.
A detector that fails its bump test should not be used for confined-space entry until the problem has been investigated and corrected.
A bump test does not replace calibration. Calibration uses certified reference gas to verify and adjust measurement accuracy.
Step 3: Test from Outside the Space
Connect the external pump and sampling hose before entry.
Allow enough time for the sample to travel through the hose and reach the sensors. A longer hose generally requires more sampling time.
The operator should consider:
Hose length
Pump flow
Sensor response time
Target gas characteristics
Volume of the sampling line
Do not record the result immediately after starting the pump because the sample may not yet have reached the detector.
Step 4: Test at Different Levels
Gases may accumulate at different heights according to their physical properties, temperature, ventilation and process conditions.
Where appropriate, test:
The upper section
The middle section
The lower section
Testing only near the opening may not represent the atmosphere deeper inside the space.
Step 5: Continue Monitoring During Entry
A safe pre-entry reading does not guarantee that conditions will remain safe.
Gas concentrations can change because of:
Welding or hot work
Cleaning chemicals
Sludge disturbance
Product residue
Ventilation failure
Leakage from connected pipelines
Engine or generator exhaust
Changes in the surrounding process
Workers should therefore continue monitoring according to the site’s confined-space procedure.
In diffusion mode, the detector should be worn within the worker’s breathing zone and must not be covered by clothing.
What Should You Do When the Alarm Activates?
If the MS104K-M produces a gas alarm:
Do not ignore or silence the warning and continue working
Leave the hazardous area according to the emergency procedure
Inform the responsible supervisor or safety personnel
Investigate the source of the alarm
Ventilate the space where appropriate
Retest before allowing re-entry
The detector is an early-warning instrument. It does not make an unsafe atmosphere safe.
Common Confined-Space Testing Mistakes
Avoid these common mistakes:
Entering the space before completing atmospheric testing
Selecting the wrong gas sensors
Testing only at the entrance
Reading the instrument before the sample reaches the sensors
Using damaged or unsuitable tubing
Skipping bump tests
Using an overdue calibration
Assuming that one initial reading is sufficient
Wearing the detector outside the breathing zone
Ignoring low-battery, pump-blockage or sensor warnings
Is the MS104K-M Suitable for Every Confined Space?
The MS104K-M is suitable when its installed sensors match the identified hazards and its measurement ranges are appropriate.
Customers should confirm:
Expected gases
Required detection ranges
Applicable sensor technology
Pump-sampling distance
Required hose material
Operating duration
Alarm settings
Documentation requirements
For specialised gases or more than four detection parameters, another Eranntex pumped multi-gas model may be more appropriate.
Why Choose MTM Precision?
MTM Precision supplies gas detectors, environmental instruments, industrial testing equipment and safety measurement solutions throughout Malaysia.
We can assist customers with:
Gas and measuring-range selection
Four-gas detector configuration
Confined-space application matching
Diffusion versus pump-suction selection
Sampling accessories
Product quotation and availability
Basic operating guidance
After-sales and technical support
Request an Eranntex MS104K-M Quotation
For a more accurate quotation, tell us:
Your industry and application
Gases to be measured
Required measuring ranges
Sampling-hose length
Number of instruments required
Required accessories
Calibration or test-report requirements
MTM Precision can help determine whether the MS104K-M, MS104K-S1, MS104K-S2 or another Eranntex gas detector matches the application.
Contact MTM Precision
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
We support customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.
14 Sep 2026