How to Choose Eranntex MS104K-M Gas Sensor Configuration Malaysia
How to Choose Eranntex MS104K-M Gas Sensor Configuration Malaysia
The Eranntex MS104K-M can detect one to four gases simultaneously, but customers must select the required gases and measuring ranges before ordering.
There is no single sensor configuration suitable for every factory, confined space or maintenance application. The correct combination must follow the actual gases that may be present at the workplace.
Common Four-Gas Configuration
One of the most common configurations is:
EX: Combustible gas, normally displayed in %LEL
O₂: Oxygen concentration
CO: Carbon monoxide
H₂S: Hydrogen sulphide
This combination is widely used for general industrial safety and confined-space entry because it covers:
Fire and explosion risk
Oxygen deficiency or enrichment
Carbon monoxide exposure
Hydrogen sulphide exposure
However, it should not automatically be specified for every application.
What Does the EX Sensor Detect?
The EX sensor is used to indicate the concentration of combustible gas as a percentage of its Lower Explosive Limit, or %LEL.
It can help identify combustible-gas accumulation before the atmosphere reaches a dangerous explosive concentration.
Possible applications include:
Oil and gas facilities
Fuel-storage areas
Petrochemical plants
Tank maintenance
Gas pipelines
Boiler rooms
Wastewater facilities
Confined spaces with combustible-gas risks
Customers should tell MTM Precision which combustible gas is expected because the sensor is normally calibrated using a particular reference gas.
Different combustible gases may produce different response characteristics.
Why Is Oxygen Monitoring Important?
Normal outdoor air contains approximately 20.9% oxygen by volume.
Oxygen levels can become unsafe when oxygen is:
Displaced by another gas
Consumed by oxidation or biological activity
Reduced by combustion
Enriched by a leaking oxygen supply
Affected by industrial processes
An oxygen sensor is particularly important for tanks, manholes, sewers, vessels and poorly ventilated areas.
Oxygen measurement does not identify which gas displaced the oxygen. Additional sensors may still be required to detect toxic or combustible substances.
Where Does Carbon Monoxide Come From?
Carbon monoxide is a colourless and odourless toxic gas commonly associated with incomplete combustion.
Possible sources include:
Engines
Generators
Boilers
Furnaces
Forklifts
Welding and hot work
Vehicle exhaust
Fire and smoke
Enclosed combustion processes
Workers cannot rely on smell to detect carbon monoxide. A suitable CO sensor is required where CO exposure is possible.
Where Is Hydrogen Sulphide Found?
Hydrogen sulphide may be encountered in:
Sewers
Wastewater treatment plants
Sludge-handling areas
Manholes
Palm oil processing
Oil and gas operations
Chemical facilities
Organic-material decomposition
Tanks containing sulphur compounds
H₂S may be recognisable by a rotten-egg smell at low concentrations, but smell must never be used as a safety test. Olfactory fatigue can cause a person to stop noticing the odour.
When Is EX/O₂/CO/H₂S Not Enough?
The standard four-gas combination does not detect every hazardous gas.
A different configuration may be required for applications involving:
Carbon dioxide
Ammonia
Sulphur dioxide
Chlorine
Nitrogen dioxide
Hydrogen
VOCs
Formaldehyde
Refrigerant gases
Other process-specific substances
For example, an oxygen reading may fall when another gas displaces air, but this does not measure the concentration of the displacement gas itself.
If carbon dioxide is the primary hazard, a dedicated CO₂ sensor may be necessary.
Can Any Four Gases Be Combined?
Not every requested combination is automatically possible.
Sensor compatibility may be affected by:
Sensor dimensions
Power consumption
Detection technology
Internal detector layout
Gas cross-sensitivity
Required measuring range
Environmental conditions
Pump and flow requirements
The manufacturer must confirm whether the selected gases can be installed together in one MS104K-M.
Choosing the Correct Measuring Range
Customers should not select a measuring range simply because a higher number appears better.
A suitable range should cover the expected concentration while maintaining the resolution and sensitivity required for the application.
When requesting a quotation, provide:
Normal background concentration
Expected working concentration
Alarm requirements
Possible maximum concentration
Applicable workplace limit
Need for leak detection or exposure monitoring
A detector for personal exposure monitoring may require a different range from an instrument intended to locate a high-concentration leak.
Sensor Technologies
Depending on the target gas and configuration, gas detectors may use technologies such as:
Electrochemical sensors
Catalytic-combustion sensors
Infrared sensors
Photoionisation detectors
Thermal-conductivity sensors
Each technology has different strengths, limitations, maintenance requirements and costs.
The sensor technology should be selected according to the target gas rather than the lowest instrument price.
Cross-Sensitivity Must Be Considered
Some gas sensors may respond partly to gases other than their intended target.
This is known as cross-sensitivity.
Cross-sensitivity does not necessarily indicate that the detector is defective. It is a characteristic that must be understood when interpreting measurements.
Customers should inform the supplier of other gases, vapours or chemicals that may be present at the site.
Pump Sampling or Diffusion?
The MS104K-M supports personal diffusion monitoring and connection to an external pump for remote sampling.
Choose diffusion monitoring when:
The detector is worn by a worker
The surrounding atmosphere needs continuous monitoring
The sampling point is safely accessible
Choose pump-suction sampling when:
Testing before confined-space entry
Sampling inside a tank or manhole
Measuring at different depths
Investigating a remote location
Approaching the sampling point may be unsafe
The pump, hose and filter must be compatible with the selected gases.
Information Required Before Ordering
To select the correct MS104K-M configuration, answer these questions:
Which gases may be present?
How many gases must be measured simultaneously?
What measuring range is required for each gas?
Is the application for personal safety, leak detection or environmental measurement?
Is confined-space pre-entry testing required?
Is pump-suction sampling needed?
What sampling distance is required?
Are there interfering gases or vapours?
What calibration documents are required?
How many detectors are needed?
Without this information, a quotation may not match the actual application.
Why Choose MTM Precision?
MTM Precision supplies gas detectors, environmental monitoring instruments, industrial testing equipment and safety measurement solutions throughout Malaysia.
Our team can assist with:
Gas sensor configuration
Measuring-range selection
Four-gas detector comparison
Diffusion and pump-suction requirements
Confined-space application matching
Sampling hose and accessory selection
Product quotation and availability
Basic operating guidance
After-sales and technical support
Request an Eranntex MS104K-M Quotation
When contacting us, avoid requesting only a “four-gas detector.”
Tell us the gases, ranges and workplace application. MTM Precision can then confirm whether the requested sensor combination is available and whether the MS104K-M is the correct model.
Contact MTM Precision
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
We support customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.
14 Sep 2026