Gas-detector sensors do not last forever.
The sensors installed inside an Eranntex MS104K-M portable multi-gas detector can gradually lose sensitivity because of ageing, contamination, environmental exposure or repeated contact with high gas concentrations.
Understanding sensor life helps users plan calibration, replacement and purchasing without compromising workplace safety.
How Long Do Gas Detector Sensors Last?
There is no single lifespan that applies to every sensor.
Depending on the gas, sensor technology, operating environment and frequency of use, a sensor may commonly provide approximately two to three years of service. Some sensors may last longer, while others may require earlier replacement.
The actual service life starts being affected once the sensor is manufactured and activated—not only after the customer begins using the detector.
For this reason, customers should avoid keeping excessive quantities of gas detectors in storage without a clear sales or usage plan.
What Affects Sensor Life?
Sensor life can be affected by:
Type of gas sensor
Frequency of use
Gas concentration
Over-range exposure
Temperature
Humidity
Chemical contamination
Sensor-poisoning substances
Storage conditions
Calibration frequency
Physical damage
Age of the sensor
Two identical MS104K-M detectors can therefore require sensor replacement at different times.
Common Sensor Technologies
The MS104K-M may use different sensor technologies according to the selected gases.
Electrochemical Sensors
Electrochemical sensors are commonly used for gases such as:
Carbon monoxide
Hydrogen sulphide
Oxygen
Ammonia
Sulphur dioxide
Other toxic gases
These sensors contain components that are gradually consumed or affected by environmental conditions.
Catalytic-Combustion Sensors
Catalytic sensors are commonly used for combustible-gas detection in %LEL.
Their performance may be affected by exposure to sensor poisons, inhibitors or very high gas concentrations.
Infrared Sensors
Infrared sensors may be used for selected gases such as carbon dioxide or combustible hydrocarbons.
They can offer advantages in certain applications but normally have different costs, power requirements and detection limitations.
The installed sensor technology must be confirmed according to the ordered configuration.
Warning Signs of Sensor Deterioration
Possible signs that a sensor requires investigation include:
Failure during a bump test
Inability to complete calibration
Slow response to test gas
Unstable readings
Reading does not return to zero
Large difference from a reference instrument
Repeated calibration failure
Frequent sensor-error warning
Unexpected alarm in clean air
No response when gas is applied
Do not continue using the detector for safety-critical work until the issue has been checked.
Does a Successful Calibration Mean the Sensor Is New?
No.
Calibration confirms that the sensor can be adjusted to respond correctly at that time. It does not reset the sensor’s age or make an old sensor new again.
An ageing sensor may still pass calibration but later show:
Reduced sensitivity
Slower response
Shorter calibration stability
More frequent calibration drift
Calibration records and sensor age should therefore be reviewed together.
What Happens After Over-Range Exposure?
Exposure to gas above the sensor’s measuring range may affect sensor performance.
After an over-range event:
Leave the hazardous area.
Allow the detector to recover in clean air.
Follow the site’s safety procedure.
Perform the required bump test.
Arrange calibration or inspection if necessary.
Replace the sensor if it no longer responds correctly.
Do not assume that the detector remains accurate merely because the displayed reading returns to zero.
Combustible Sensor Poisoning
Certain chemicals can reduce or destroy the sensitivity of catalytic combustible-gas sensors.
Possible contaminants may include:
Silicone compounds
Lead-containing substances
Sulphur compounds
Some solvents
Corrosive chemicals
Other catalyst inhibitors
The exact effect depends on the sensor design and exposure.
A poisoned sensor may show a normal zero reading but fail to respond adequately to combustible gas. This is one reason regular bump testing is essential.
Storage Conditions Matter
Even detectors kept in storage require proper management.
Avoid storing the MS104K-M in locations with:
Extreme heat
Excessive humidity
Direct sunlight
Corrosive vapours
Solvent fumes
Dust contamination
Water exposure
Deeply discharged batteries
Detectors kept as standby units should still be inspected, charged, tested and calibrated according to the applicable schedule.
Should You Keep Many Gas Detectors in Stock?
Gas detectors differ from ordinary tools because the sensors have a finite service life.
For distributors and end users, a better approach is often to:
Keep practical quantities for immediate requirements
Confirm sensor production dates
Rotate inventory
Record detector and sensor details
Avoid excessive slow-moving configurations
Reorder according to actual demand
Keep common configurations rather than too many unusual combinations
Special-gas configurations can be ordered according to confirmed customer requirements.
When Should the Sensor Be Replaced?
Sensor replacement should be considered when:
It fails calibration
It fails a bump test
The detector reports a sensor fault
Response becomes unacceptably slow
Readings remain unstable
The sensor reaches its recommended service-life limit
It has been damaged or contaminated
Technical inspection confirms poor performance
A replacement sensor must match the gas, range and detector configuration.
Can Customers Replace the Sensor Themselves?
Sensor replacement may involve more than physically installing a new component.
After replacement, the detector may require:
Correct sensor identification
Parameter configuration
Fresh-air adjustment
Span calibration
Alarm verification
Leak or flow checking
Functional testing
Record updating
For safety-critical instruments, replacement and calibration should be handled by appropriately trained personnel using suitable equipment and certified test gas.
Information Needed for a Sensor Enquiry
When requesting a replacement sensor or technical assessment, provide:
Full detector model
Serial number
Gas type
Measuring range
Existing sensor technology
Sensor installation date, if known
Last calibration date
Error message or symptoms
Required quantity
Photos of the detector label and display
Do not request only an “MS104K-M sensor,” because the instrument can be supplied with different gases and ranges.
Plan for Future Operating Cost
The purchase price is only one part of owning a gas detector.
Customers should also consider:
Bump-test gas
Calibration gas
Regulators and adapters
Filters
Sampling hoses
Battery condition
Periodic calibration
Sensor replacement
Technical inspection
Downtime during servicing
Choosing a detector with accessible technical support can reduce future disruption.
Why Choose MTM Precision?
MTM Precision supplies gas detectors, environmental monitoring instruments, industrial testing equipment and safety measurement solutions throughout Malaysia.
Our team can assist with:
MS104K-M configuration selection
Sensor-life enquiries
Replacement-sensor identification
Bump-test and calibration requirements
Pump and sampling accessories
Product quotation and availability
Basic operating guidance
After-sales and technical coordination
Request an Eranntex MS104K-M Quotation
For a suitable detector configuration, tell us:
Gases to be measured
Required measuring ranges
Workplace application
Expected frequency of use
Diffusion or pump-sampling requirement
Quantity required
Calibration-document requirements
MTM Precision can help match the detector and sensor configuration to the actual application.
Contact MTM Precision
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
We support customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.
14 Sep 2026