Eranntex MS104K-M Price and Quotation Guide Malaysia
Eranntex MS104K-M Price and Quotation Guide Malaysia
The price of an Eranntex MS104K-M portable multi-gas detector depends on its sensor configuration, measuring ranges, sampling accessories and documentation requirements.
Because the MS104K-M can detect between one and four gases, there is no single price that applies to every configuration.
Customers should provide the required gas details before requesting a formal quotation.
What Affects the MS104K-M Price?
The main factors include:
Number of installed gas sensors
Type of gases
Measuring range of each gas
Sensor technology
Diffusion or pump-sampling accessories
Sampling-hose length
Probe and filter requirements
Data or communication options
Calibration requirements
Certification and documentation
Order quantity
Delivery schedule
A detector fitted with specialised sensors can cost significantly more than a standard four-gas unit.
Standard Four-Gas Configuration
A commonly requested configuration is:
EX: Combustible gas in %LEL
O₂: Oxygen
CO: Carbon monoxide
H₂S: Hydrogen sulphide
This combination is widely used for confined-space entry, factory maintenance, manhole inspection and general industrial safety.
Customers should still confirm whether these are the actual hazards at their workplace.
Why Special-Gas Configurations Cost More
Some gases require more expensive sensor technologies or specialised measuring ranges.
Examples may include:
Carbon dioxide
Ammonia
Sulphur dioxide
Chlorine
VOCs
Hydrogen
Formaldehyde
Other application-specific gases
The final price may be affected by:
Sensor manufacturing cost
Sensor service life
Required accuracy
Detection range
Resolution
Cross-sensitivity requirements
Calibration-gas availability
Combination compatibility
A specialised four-gas configuration should therefore not be expected to cost the same as EX/O₂/CO/H₂S.
Pump and Sampling Accessories
The MS104K-M supports external pump-suction measurement for remote gas sampling.
Depending on the job, the quotation may include:
External sampling pump
Sampling hose
Telescopic or fixed probe
Dust filter
Moisture filter
Water trap
Calibration cap
Carrying case
Charging accessories
The required hose material and length should be selected according to the target gas and sampling environment.
Why Hose Length Must Be Confirmed
A longer sampling hose may be required for tanks, manholes, deep chambers or other confined spaces.
However, hose length affects:
Sample travel time
Pump load
Flow rate
Response time
Risk of condensation
Possibility of gas absorption
Customers should provide the approximate sampling depth instead of requesting an unspecified “long hose.”
Calibration and Documentation
The quoted price may vary according to the required documentation.
Customers should state whether they need:
Factory test report
Calibration report
Local calibration certificate
Serial-number traceability
Sensor information
Product certification documents
Project submission documents
A factory test report and a third-party or accredited calibration certificate are not necessarily the same.
The required document type should be confirmed before ordering.
Initial Price vs Long-Term Cost
The lowest purchase price may not provide the lowest ownership cost.
Gas-detector users should consider:
Sensor replacement
Calibration frequency
Bump-test gas
Calibration gas
Filters
Sampling hoses
Battery condition
Technical support
Instrument downtime
Availability of replacement parts
Gas sensors have a finite service life, commonly around two to three years depending on the sensor and operating conditions.
Should You Buy Extra Units for Stock?
Keeping standby detectors can reduce downtime, but excessive storage may waste sensor life.
A practical approach is to:
Purchase according to the number of workers
Include a reasonable standby quantity
Record sensor and instrument dates
Rotate detectors
Maintain charging and test schedules
Avoid holding too many unusual configurations
Reorder according to confirmed demand
For uncommon gases, it may be better to order against a specific customer or project requirement.
How Many Detectors Does a Company Need?
The required quantity depends on:
Number of workers
Number of entry teams
Shift arrangement
Whether each worker needs personal monitoring
Number of simultaneous work locations
Need for standby units
Calibration and servicing rotation
One detector may not be sufficient for several workers operating at different locations.
The company’s safety officer should determine detector allocation according to the risk assessment and work procedure.
Questions to Include in Your Enquiry
For an accurate MS104K-M quotation, provide:
Which gases need to be detected?
What measuring range is required for each gas?
What is the workplace application?
Is the detector for personal monitoring or leak investigation?
Is confined-space pre-entry testing required?
Is pump-suction sampling needed?
What sampling-hose length is required?
How many detectors are needed?
What accessories are required?
What calibration or certification documents are needed?
Photos of the work location or an existing detector label may also help clarify the requirement.
Avoid Asking Only for a “Four-Gas Detector”
The phrase “four-gas detector” does not provide enough information for an accurate quotation.
Two instruments can both detect four gases but have very different:
Gas combinations
Measuring ranges
Sensor technologies
Sampling methods
Certifications
Accessories
Prices
A good quotation should match the detector to the hazard rather than simply offer the cheapest four-sensor unit.
MS104K-M vs Lower-Cost Alternatives
The Eranntex MS104K-M may be more suitable than a basic entry-level detector when the customer requires:
Configurable detection of up to four gases
Diffusion and pump-suction sampling
Remote confined-space testing
Pump-blockage warning
Data storage
Multiple alarm modes
Industrial application flexibility
Manufacturer technical support
For basic single-gas monitoring, an MS104K-S1 may be more economical.
For one or two gases without remote sampling, an MS104K-S2 may be sufficient.
Why Choose MTM Precision?
MTM Precision supplies gas detectors, environmental monitoring instruments, industrial testing equipment and safety measurement solutions throughout Malaysia.
Our team can assist with:
Gas and measuring-range selection
MS104K model comparison
Four-gas detector configuration
Pump and diffusion requirements
Sampling accessory selection
Calibration-document clarification
Product quotation and availability
Basic operating guidance
After-sales and technical coordination
Request an Eranntex MS104K-M Price
For the most relevant quotation, send us:
Gas names
Required ranges
Intended application
Pump-sampling requirement
Hose length
Quantity
Accessories
Required certificates or reports
MTM Precision will review the requirement and recommend a suitable configuration rather than quote an unspecified detector.
Contact MTM Precision
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
We support customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.
14 Sep 2026