Carbon monoxide is a colourless and odourless toxic gas commonly produced when fuel does not burn completely.

 

Workers cannot see or smell CO. A suitable gas detector is therefore required where carbon monoxide may accumulate.

 

The Eranntex MS104K-M portable multi-gas detector can be configured with a CO sensor together with other gases for factory maintenance, confined-space entry and industrial safety monitoring.

 

Where Does Carbon Monoxide Come From?

 

Possible CO sources include:

 

Generators

 

Boilers

 

Furnaces

 

Vehicle exhaust

 

Petrol or diesel engines

 

Forklifts

 

Welding and hot work

 

Fires and smoke

 

Heaters

 

Poorly maintained combustion equipment

 

Incomplete combustion inside process systems

 

Risk increases when combustion equipment operates in a poorly ventilated or enclosed area.

 

Why Is Carbon Monoxide Dangerous?

 

Carbon monoxide interferes with the body’s ability to transport oxygen.

 

Exposure may cause symptoms such as:

 

Headache

 

Dizziness

 

Weakness

 

Nausea

 

Confusion

 

Loss of coordination

 

Unconsciousness

 

These symptoms can be mistaken for tiredness or illness. Personnel should not rely on physical symptoms to identify a hazardous atmosphere.

 

Any suspected exposure should be managed according to the organisation’s emergency and medical procedures.

 

Why Use CO with Other Gas Sensors?

 

Carbon monoxide may not be the only hazard.

 

A commonly selected MS104K-M configuration includes:

 

CO: Carbon monoxide

 

O₂: Oxygen

 

EX: Combustible gas

 

H₂S: Hydrogen sulphide

 

This allows one instrument to monitor several common industrial and confined-space hazards simultaneously.

 

The final gas combination should always follow the workplace risk assessment.

 

CO Monitoring in Boiler Rooms

 

Carbon monoxide may be generated when boiler combustion is incomplete.

 

Possible contributing conditions include:

 

Poor ventilation

 

Blocked flue or exhaust

 

Incorrect burner adjustment

 

Insufficient combustion air

 

Equipment malfunction

 

Exhaust recirculation

 

Fuel-system problems

 

A portable detector can support inspection and maintenance, but it does not replace fixed monitoring, ventilation or proper boiler servicing where these controls are required.

 

CO Monitoring Around Generators

 

Running a generator indoors or near an air intake can allow exhaust gases to accumulate.

 

CO may enter:

 

Generator rooms

 

Basements

 

Temporary work enclosures

 

Utility rooms

 

Adjacent offices

 

Underground spaces

 

Poorly ventilated work zones

 

Technicians should assess the complete area rather than measure only beside the generator.

 

CO During Welding and Hot Work

 

Hot work can change atmospheric conditions, especially inside tanks and confined spaces.

 

Carbon monoxide may be generated during certain combustion and welding activities. Oxygen and combustible-gas risks may also be present.

 

Monitoring may therefore be required before and throughout the work according to the hot-work permit and safety procedure.

 

Diffusion Mode for Personal CO Monitoring

 

In diffusion mode, the MS104K-M measures the air surrounding the worker.

 

For personal monitoring, the detector should be:

 

Positioned within the breathing zone

 

Exposed to the surrounding atmosphere

 

Visible or audible to the user

 

Kept away from obstruction by clothing

 

Checked according to the site procedure

 

The detector should accompany the worker rather than remain at the entrance to the work area.

 

Pump Sampling for Remote Locations

 

When the suspected atmosphere cannot be approached safely, the external pump can draw a sample through a hose or probe.

 

Possible applications include:

 

Tank pre-entry testing

 

Manhole inspection

 

Underground chamber checks

 

Enclosed machinery spaces

 

Boiler or process-vessel inspection

 

Investigation behind a barrier

 

Allow sufficient time for the gas sample to travel through the hose and reach the sensor.

 

What Measuring Range Is Required?

 

The required CO range depends on whether the detector is used for:

 

Personal exposure monitoring

 

Confined-space safety

 

Leak investigation

 

Combustion troubleshooting

 

Emergency response

 

High-concentration process measurement

 

Do not select a range only because it has a higher maximum value.

 

A range that is too broad may not provide the resolution required for low-level monitoring. The expected concentration and alarm requirements should be confirmed before ordering.

 

CO Sensor Cross-Sensitivity

 

Electrochemical CO sensors may respond to certain interfering gases.

 

The actual cross-sensitivity depends on the sensor model and technology.

 

Customers should inform MTM Precision if the workplace contains:

 

Hydrogen

 

Solvents

 

Alcohol vapours

 

Other toxic gases

 

Unusual process chemicals

 

Technical confirmation may be necessary when interfering substances are expected.

 

Why Does the CO Reading Not Return to Zero?

 

Possible causes include:

 

CO remains in the area

 

Poor ventilation

 

Gas trapped inside the sampling hose

 

Sensor recovery after high exposure

 

Contaminated filter or tubing

 

Incorrect fresh-air adjustment

 

Calibration drift

 

Ageing sensor

 

Cross-sensitive gas

 

Sensor fault

 

Move the detector to a known clean atmosphere and follow the required checking procedure.

 

Do not automatically zero the detector if the surrounding air cannot be confirmed as clean.

 

What If the CO Alarm Activates?

 

If a CO alarm occurs:

 

Follow the site’s emergency procedure

 

Leave the affected area

 

Do not ignore or silence the alarm

 

Warn nearby personnel

 

Stop the suspected source where authorised and safe

 

Improve ventilation where appropriate

 

Investigate from a safe location

 

Retest before allowing work to resume

 

The detector provides a warning but does not remove the source of carbon monoxide.

 

Bump Test and Calibration

 

A bump test confirms that the CO sensor and alarms respond when exposed to test gas.

 

Calibration verifies and adjusts measurement accuracy using certified reference gas.

 

The MS104K-M may require calibration or technical inspection after:

 

A failed bump test

 

Sensor replacement

 

Over-range CO exposure

 

Long-term storage

 

Physical damage

 

Unstable readings

 

Scheduled calibration expiry

 

A detector that fails its functional check should be removed from safety use.

 

Common CO Monitoring Mistakes

 

Avoid:

 

Depending on smell

 

Assuming open doors provide enough ventilation

 

Leaving the detector outside the worker’s breathing zone

 

Using the wrong CO measuring range

 

Recording a pump sample too quickly

 

Ignoring cross-sensitivity

 

Zeroing in an unknown atmosphere

 

Skipping bump tests

 

Continuing work after an alarm

 

Assuming a normal oxygen reading means CO is absent

 

Oxygen and carbon monoxide are separate measurements.

 

Information Required for a CO Detector Quotation

 

Provide:

 

Workplace and application

 

Expected CO source

 

Required CO measuring range

 

Other gases to be monitored

 

Diffusion or pump-sampling requirement

 

Sampling distance

 

Number of detectors

 

Required accessories

 

Calibration or documentation requirements

 

This allows the detector to be configured according to the actual risk.

 

Why Choose MTM Precision?

 

MTM Precision supplies gas detectors, environmental monitoring instruments, industrial testing equipment and safety measurement solutions throughout Malaysia.

 

Our team can assist with:

 

CO detector selection

 

Multi-gas sensor configuration

 

Measuring-range confirmation

 

Factory and confined-space application matching

 

Diffusion and pump-sampling requirements

 

Sampling accessories

 

Product quotation and availability

 

Basic operating guidance

 

After-sales and technical coordination

 

Request an Eranntex MS104K-M Quotation

 

Tell MTM Precision where the carbon monoxide may come from and which additional gases need to be monitored.

 

We can help determine whether a CO-equipped MS104K-M is suitable for the application.

 

Contact MTM Precision

 

MTM Precision Sdn Bhd

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Website: www.mtmpre.com.my

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

 

We support customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.


 

14 Sep 2026