Monitor Water Turbidity Before and After Filtration with QiWei WGZ-1B Malaysia

Monitor Water Turbidity Before and After Filtration Malaysia

 

How can you check whether a water-filtration system is actually improving water clarity?

 

Visual inspection alone may not reveal gradual changes in filtration performance. By measuring turbidity before and after filtration, maintenance teams can obtain numerical results and identify changes more consistently.

 

The QiWei WGZ-1B Portable Turbidity Meter measures water turbidity from 0 to 200 NTU, making it suitable for routine checking of clear to moderately turbid water samples.

 

โญ QiWei WGZ-1B Main Specifications

 

Measurement parameter: Turbidity

 

Measuring unit: NTU

 

Measuring range: 0–200 NTU

 

Minimum display: 0.1 NTU

 

Measurement principle: 90° scattered light

 

Repeatability: ≤1%

 

Zero drift: ±1%

 

Power supply: 5 × AA batteries or AC adapter

 

LCD display

 

Automatic power-off

 

Portable carrying case

 

Sample vials and Formazine standard solution included

 

๐Ÿ’ง Why Measure Turbidity Before and After Filtration?

 

A filtration system removes or reduces particles suspended in water. Measuring turbidity at different stages helps users assess whether the process is reducing water cloudiness.

 

Typical monitoring points include:

 

Raw-water inlet

 

Before filtration

 

After filtration

 

Storage tank

 

Final process-water outlet

 

Distribution point

 

Comparing these readings can provide an early indication of changes in filter performance.

 

๐Ÿ“Š Example of a Turbidity Comparison

 

A technician takes three samples:

 

Sampling PointExample ReadingInterpretationRaw-water inlet18.5 NTUWater entering the treatment processBefore final filtration7.2 NTUPartial reduction after treatmentAfter filtration1.1 NTULower turbidity after filtration

 

These values are only examples. Actual acceptance limits depend on the application, process requirements and applicable testing standards.

 

The most useful comparison is made when samples are collected and measured using the same procedure.

 

๐Ÿญ Suitable Water-Treatment Applications

 

The QiWei WGZ-1B may be used for routine turbidity monitoring in:

 

Commercial water-treatment systems

 

Industrial process-water systems

 

Building water-filtration systems

 

Swimming-pool filtration

 

Food and beverage facilities

 

Cooling-water treatment

 

Rainwater-harvesting systems

 

Educational laboratories

 

Environmental water testing

 

General quality-control applications

 

๐Ÿ” What Can a Rising Turbidity Reading Indicate?

 

An increase in turbidity after filtration may be associated with:

 

Filter media becoming dirty

 

Filter breakthrough

 

Insufficient backwashing

 

Damaged filter media

 

Incorrect chemical dosing

 

Poor settling or clarification

 

Increased raw-water contamination

 

Tank sediment disturbance

 

Contamination entering after filtration

 

Inconsistent sample collection

 

A turbidity result identifies a change in water clarity. Further inspection is normally required to determine the actual cause.

 

๐Ÿงช Recommended Testing Procedure

 

1. Select Fixed Sampling Points

 

Use the same locations for each monitoring session so that results can be compared properly.

 

2. Flush the Sampling Outlet

 

Allow stagnant water to clear before collecting the sample, according to the site’s established procedure.

 

3. Use Clean Sample Vials

 

Dirty, scratched or stained vials may interfere with optical measurement.

 

4. Remove Air Bubbles

 

Air bubbles scatter light and may cause the displayed turbidity result to increase.

 

5. Clean the Outside of the Vial

 

Remove fingerprints, dust and water droplets using a clean, lint-free cloth.

 

6. Measure Consistently

 

Use the same sample volume, vial orientation and waiting time whenever possible.

 

7. Record the Result

 

Record the sampling point, date, time, NTU reading and relevant operating condition.

 

8. Compare the Trend

 

Review changes over time instead of relying only on a single result.

 

โš ๏ธ Common Reasons for Unstable Readings

 

Air Bubbles

 

Bubbles may form when the sample is collected under pressure or shaken before testing.

 

Settling Particles

 

Larger particles may settle between sample collection and measurement, producing inconsistent readings.

 

Condensation

 

Moisture on the outside of a cold vial can affect the optical path.

 

Fingerprints

 

Fingerprints or oil on the vial may scatter light.

 

Scratched Glass

 

Scratched sample vials should be replaced.

 

Different Sampling Locations

 

Results from different points should not be compared without clearly recording where each sample was collected.

 

Poor Calibration Practice

 

Use suitable turbidity standards and follow the correct calibration procedure.

 

๐Ÿ› ๏ธ How Turbidity Monitoring Supports Preventive Maintenance

 

Routine turbidity records can help maintenance teams decide when to:

 

Inspect the filtration system

 

Perform backwashing

 

Replace filter cartridges

 

Check chemical dosing

 

Clean storage tanks

 

Investigate contamination

 

Review changes in raw-water quality

 

Take samples for further laboratory analysis

 

Turbidity trending can reveal gradual deterioration before the water becomes visibly cloudy.

 

๐Ÿ“‹ Suggested Turbidity Record

 

Record the following information for every measurement:

 

Date and time

 

Sampling location

 

Turbidity reading in NTU

 

Filter operating hours

 

Differential pressure, if available

 

Backwash or cartridge-replacement date

 

Chemical-treatment condition

 

Visual appearance

 

Name of technician

 

Corrective action taken

 

Consistent records make troubleshooting easier and improve communication between operators, contractors and management.

 

โš ๏ธ When Is WGZ-1B Not Suitable?

 

The WGZ-1B may not be the correct choice when:

 

Expected turbidity exceeds 200 NTU

 

Results must be reported as suspended solids in mg/L

 

The sample contains heavy sludge

 

Continuous online monitoring is required

 

A specific regulatory test method is mandatory

 

Extremely low turbidity requires higher resolution or specialised compliance equipment

 

For these applications, consider a higher-range turbidity meter, dedicated suspended-solids meter, online sensor or laboratory method.

 

โœ… Why Choose the QiWei WGZ-1B?

 

The WGZ-1B offers:

 

Portable turbidity measurement

 

Useful 0–200 NTU range

 

Simple routine operation

 

AC and battery power

 

Numerical comparison of water clarity

 

Field and laboratory flexibility

 

Practical support for filter-performance checks

 

An economical solution for general water-quality monitoring

 

๐Ÿ›’ Information Required for Model Selection

 

When requesting a quotation, provide:

 

Type of water being tested

 

Expected turbidity range

 

Sampling points

 

Testing frequency

 

Laboratory or field application

 

Internal monitoring or official reporting

 

Required certificate or test standard

 

Delivery location

 

MTM Precision can help determine whether the QiWei WGZ-1B, a higher-range turbidity meter or a suspended-solids instrument is more suitable.

 

๐Ÿ“ QiWei Water-Quality Instruments Malaysia

 

MTM Precision supplies water-quality instruments for customers in Selangor, Kuala Lumpur, Johor, Penang, Perak, Melaka, Negeri Sembilan, Pahang, Kedah, Perlis, Terengganu, Kelantan, Sabah and Sarawak.

 

Available categories include turbidity, suspended solids, pH, conductivity, TDS, salinity, dissolved oxygen, ORP, residual chlorine and multiparameter water-quality measurement.

 

๐Ÿ“ž Contact MTM Precision

 

MTM Precision Sdn Bhd

 

Tel / WhatsApp: +6016-660 7346

Office: +603-8080 7172

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

Showroom & Service Centre:

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Contact MTM Precision for the QiWei WGZ-1B price, availability, technical information and delivery throughout Malaysia.


 

15 Sep 2026