How to Check New Furniture and Cabinets with NOYAFA JMS11 or JMS12 Malaysia

Checking Indoor Air Around New Furniture and Cabinets

 

New wardrobes, kitchen cabinets, desks, shelving and other furniture may introduce a noticeable smell into a room.

 

The smell may originate from:

 

Composite wood

 

Adhesive

 

Coatings

 

Paint

 

Laminate

 

Edge-sealing materials

 

Packaging

 

Cleaning products

 

The NOYAFA JMS11 and NOYAFA JMS12 can be used for preliminary screening of formaldehyde (HCHO) and total volatile organic compounds (TVOC) around new furniture.

 

The purpose is to compare locations and observe changes. These portable detectors do not identify the exact chemical composition of the furniture and do not replace laboratory testing.

 

Why Can New Furniture Affect Indoor Air?

 

Furniture can be manufactured from different materials, including:

 

Solid wood

 

Plywood

 

Particleboard

 

Medium-density fibreboard

 

Laminated panels

 

Metal

 

Plastic

 

Fabric

 

Foam

 

Composite wood products may use resins or adhesives during manufacturing. Coatings, laminate, edge treatments and cleaning products may also release volatile compounds.

 

The amount released into a room can vary according to:

 

Type of material

 

Manufacturing process

 

Age of the furniture

 

Surface area

 

Room temperature

 

Humidity

 

Ventilation

 

Whether cabinet doors remain closed

 

Length of time since installation

 

A strong smell alone cannot determine the concentration or identify a specific chemical.

 

What Can JMS11 and JMS12 Measure?

 

Both models provide preliminary readings for:

 

HCHO—formaldehyde

 

TVOC—total volatile organic compounds

 

The JMS12 also displays:

 

Temperature

 

Relative humidity

 

Temperature and humidity are useful because the room environment may change between morning and afternoon or between air-conditioned and non-air-conditioned conditions.

 

Which Model Is Better for Furniture Checks?

 

Choose NOYAFA JMS11 when:

 

You need basic HCHO and TVOC screening.

 

You only perform occasional checks.

 

You prefer replaceable batteries.

 

Affordability is the main priority.

 

You want a simple detector for home use.

 

Choose NOYAFA JMS12 when:

 

You also want temperature and humidity.

 

You plan to repeat the test over several days.

 

You are checking multiple rooms or properties.

 

You want a more complete measurement record.

 

You prefer rechargeable operation.

 

For repeated checks around new furniture, the JMS12 provides more environmental information. The JMS11 remains sufficient for straightforward screening.

 

General Room Test vs Source Test

 

A common mistake is to place the detector directly inside a newly installed cabinet and assume that the reading represents the entire room.

 

These are two different tests.

 

General room test

 

This test examines the condition in the occupied area.

 

Place the detector:

 

In an open position

 

Away from direct air-conditioner airflow

 

Away from windows

 

At a location representative of normal room use

 

With the ventilation openings unobstructed

 

Source-investigation test

 

This test examines whether the response becomes stronger near a particular item.

 

Possible positions include:

 

Beside the wardrobe

 

Near a cabinet panel

 

Inside a closed cabinet

 

Near a new desk

 

Close to a new mattress or upholstered item

 

Label source-level readings separately. Do not present a concentrated cabinet reading as the general room concentration.

 

Step-by-Step Furniture Testing Method

 

Step 1: Remove interfering products

 

Before testing, remove or avoid using:

 

Perfume

 

Air freshener

 

Alcohol-based sanitiser

 

Furniture polish

 

Cleaning spray

 

Insecticide

 

Solvent

 

Strongly scented products

 

These substances may influence the sensor and make it difficult to determine whether the furniture is responsible.

 

Step 2: Switch on the detector

 

Turn on the JMS11 or JMS12 in a clean and ventilated environment whenever practical.

 

Step 3: Take a general room reading

 

Place the detector in the centre or normal occupied section of the room.

 

Allow the displayed values to stabilise before recording:

 

HCHO

 

TVOC

 

Temperature and humidity if using the JMS12

 

Time

 

Door and window condition

 

Step 4: Take a reading near the furniture

 

Move the detector near the new furniture without pressing it directly against the surface.

 

Allow the reading to respond and stabilise.

 

Record this as the near-furniture reading.

 

Step 5: Test inside the cabinet if required

 

Open the cabinet carefully and place the detector in a suitable position without blocking its air openings.

 

The reading inside a closed cabinet may be significantly higher because the internal air volume is small and poorly ventilated.

 

Record this as the inside-cabinet reading.

 

Step 6: Ventilate the room and furniture

 

Open the room windows where suitable and leave cabinet doors or drawers open.

 

After ventilation, repeat the general room and near-furniture measurements.

 

Step 7: Repeat on another day

 

Repeat the same procedure under similar conditions. A consistent trend is more useful than one isolated measurement.

 

Suggested Test Record

 

LocationTest conditionHCHOTVOCTemperatureHumidityBedroom centreRoom closedRecordRecordJMS12JMS12Near wardrobeDoors closedRecordRecordJMS12JMS12Inside wardrobeCabinet closedRecordRecordJMS12JMS12Bedroom centreAfter ventilationRecordRecordJMS12JMS12Near wardrobeAfter ventilationRecordRecordJMS12JMS12

 

This table keeps general room readings separate from concentrated source-investigation readings.

 

Why Is the Reading Higher Inside the Cabinet?

 

A closed cabinet has limited ventilation and a much smaller internal air volume than the room.

 

Volatile compounds released from:

 

Wood panels

 

Adhesive

 

Laminate

 

Edge seals

 

Coatings

 

Stored products

 

may accumulate inside.

 

The higher internal reading does not automatically mean that the whole room has the same condition.

 

Open the cabinet doors, improve room ventilation and repeat the measurements.

 

Why Does the Reading Drop After Opening Cabinet Doors?

 

Opening the doors allows the accumulated vapours to mix with the larger volume of room air.

 

If windows are also opened, fresh-air exchange may further reduce the concentration.

 

The reading may rise again after the cabinet and room remain closed. Repeating the test helps determine whether this pattern is consistent.

 

Why Does the Reading Increase During the Afternoon?

 

Furniture and building materials may release volatile compounds differently as the room becomes warmer.

 

A west-facing bedroom or closed condominium unit may reach a higher temperature during the afternoon.

 

Other possible changes include:

 

Reduced ventilation

 

Higher humidity

 

Direct sunlight on furniture

 

Air conditioning being switched off

 

Longer room-closure time

 

The JMS12 allows temperature and humidity to be recorded with the HCHO and TVOC readings.

 

Can Furniture Smell Confirm Formaldehyde?

 

No. Odour alone cannot confirm that formaldehyde is present or determine its concentration.

 

A furniture smell may include several volatile substances from:

 

Adhesive

 

Coating

 

Packaging

 

Plastic

 

Foam

 

Cleaning agents

 

Wood products

 

Similarly, the absence of a strong smell does not prove that no volatile compounds are present.

 

The JMS11 and JMS12 provide screening information but do not chemically identify every substance.

 

Why Does Furniture Polish Cause a High TVOC Reading?

 

Furniture polish, cleaning spray and fragrance products may contain volatile ingredients.

 

If a cabinet is cleaned immediately before testing, the detector may respond to the cleaning product rather than only to emissions from the furniture material.

 

For a more meaningful comparison:

 

Stop using the cleaning product.

 

Remove the bottle or cloth from the area.

 

Ventilate the room.

 

Allow the environment to stabilise.

 

Repeat the test later.

 

Always record whether cleaning was recently performed.

 

Should New Cabinets Be Kept Open?

 

Opening cabinet doors and drawers can help trapped vapours disperse into the room, where they may then be removed through ventilation.

 

Practical actions may include:

 

Opening cabinet doors

 

Opening drawers

 

Increasing fresh-air exchange

 

Avoiding immediate storage of fragrance products

 

Keeping the room suitably ventilated

 

Repeating measurements over time

 

Ventilation requirements depend on the property and outdoor conditions. Consider security, rain and outdoor pollution before leaving windows open.

 

Can an Air Purifier Remove HCHO and TVOC?

 

Air purifiers are designed with different filtration technologies.

 

A standard particulate filter may be effective for particles but may not necessarily remove gaseous pollutants effectively.

 

When selecting equipment for gaseous pollutants, check whether it includes suitable gas-phase filtration, such as an appropriate activated-carbon or chemical filtration stage.

 

Filter capacity, airflow and replacement frequency are also important.

 

Do not assume that a lower PM2.5 reading means HCHO or TVOC has also been removed.

 

When Is Professional Testing Necessary?

 

Consider professional testing when:

 

Readings remain elevated after repeated ventilation

 

Occupants experience persistent discomfort

 

A certified property report is required

 

A dispute exists between buyer, tenant, contractor or furniture supplier

 

Employee exposure must be evaluated

 

A particular chemical must be identified

 

Regulatory compliance must be demonstrated

 

A portable semiconductor detector is intended for screening and comparison, not certified laboratory identification.

 

Important Sensor Precautions

 

Avoid exposing the JMS11 or JMS12 directly to:

 

Liquid

 

Concentrated solvent

 

Wet paint vapour

 

Open chemical containers

 

Aerosol spray

 

Excessive heat

 

Heavy condensation

 

Keep the air openings clean and unobstructed.

 

If the detector is exposed to perfume, alcohol or concentrated chemical vapour, move it to clean, ventilated air and allow the readings to recover before performing another test.

 

Buy NOYAFA JMS11 and JMS12 in Malaysia

 

MTM Precision supplies the NOYAFA JMS11 and JMS12 for preliminary checks around furniture, cabinets, renovated rooms, offices and vehicles.

 

Contact us for:

 

Current stock availability

 

JMS11 and JMS12 comparison

 

Updated specifications

 

Suitable model selection

 

Alternative PM2.5 or CO2 instruments

 

Basic operating guidance

 

Delivery throughout Malaysia

 

Collection from our Puchong showroom

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre:

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.


 

18 Sep 2026