How to Check New Furniture and Cabinets with NOYAFA JMS11 or JMS12 Malaysia
Checking Indoor Air Around New Furniture and Cabinets
New wardrobes, kitchen cabinets, desks, shelving and other furniture may introduce a noticeable smell into a room.
The smell may originate from:
Composite wood
Adhesive
Coatings
Paint
Laminate
Edge-sealing materials
Packaging
Cleaning products
The NOYAFA JMS11 and NOYAFA JMS12 can be used for preliminary screening of formaldehyde (HCHO) and total volatile organic compounds (TVOC) around new furniture.
The purpose is to compare locations and observe changes. These portable detectors do not identify the exact chemical composition of the furniture and do not replace laboratory testing.
Why Can New Furniture Affect Indoor Air?
Furniture can be manufactured from different materials, including:
Solid wood
Plywood
Particleboard
Medium-density fibreboard
Laminated panels
Metal
Plastic
Fabric
Foam
Composite wood products may use resins or adhesives during manufacturing. Coatings, laminate, edge treatments and cleaning products may also release volatile compounds.
The amount released into a room can vary according to:
Type of material
Manufacturing process
Age of the furniture
Surface area
Room temperature
Humidity
Ventilation
Whether cabinet doors remain closed
Length of time since installation
A strong smell alone cannot determine the concentration or identify a specific chemical.
What Can JMS11 and JMS12 Measure?
Both models provide preliminary readings for:
HCHO—formaldehyde
TVOC—total volatile organic compounds
The JMS12 also displays:
Temperature
Relative humidity
Temperature and humidity are useful because the room environment may change between morning and afternoon or between air-conditioned and non-air-conditioned conditions.
Which Model Is Better for Furniture Checks?
Choose NOYAFA JMS11 when:
You need basic HCHO and TVOC screening.
You only perform occasional checks.
You prefer replaceable batteries.
Affordability is the main priority.
You want a simple detector for home use.
Choose NOYAFA JMS12 when:
You also want temperature and humidity.
You plan to repeat the test over several days.
You are checking multiple rooms or properties.
You want a more complete measurement record.
You prefer rechargeable operation.
For repeated checks around new furniture, the JMS12 provides more environmental information. The JMS11 remains sufficient for straightforward screening.
General Room Test vs Source Test
A common mistake is to place the detector directly inside a newly installed cabinet and assume that the reading represents the entire room.
These are two different tests.
General room test
This test examines the condition in the occupied area.
Place the detector:
In an open position
Away from direct air-conditioner airflow
Away from windows
At a location representative of normal room use
With the ventilation openings unobstructed
Source-investigation test
This test examines whether the response becomes stronger near a particular item.
Possible positions include:
Beside the wardrobe
Near a cabinet panel
Inside a closed cabinet
Near a new desk
Close to a new mattress or upholstered item
Label source-level readings separately. Do not present a concentrated cabinet reading as the general room concentration.
Step-by-Step Furniture Testing Method
Step 1: Remove interfering products
Before testing, remove or avoid using:
Perfume
Air freshener
Alcohol-based sanitiser
Furniture polish
Cleaning spray
Insecticide
Solvent
Strongly scented products
These substances may influence the sensor and make it difficult to determine whether the furniture is responsible.
Step 2: Switch on the detector
Turn on the JMS11 or JMS12 in a clean and ventilated environment whenever practical.
Step 3: Take a general room reading
Place the detector in the centre or normal occupied section of the room.
Allow the displayed values to stabilise before recording:
HCHO
TVOC
Temperature and humidity if using the JMS12
Time
Door and window condition
Step 4: Take a reading near the furniture
Move the detector near the new furniture without pressing it directly against the surface.
Allow the reading to respond and stabilise.
Record this as the near-furniture reading.
Step 5: Test inside the cabinet if required
Open the cabinet carefully and place the detector in a suitable position without blocking its air openings.
The reading inside a closed cabinet may be significantly higher because the internal air volume is small and poorly ventilated.
Record this as the inside-cabinet reading.
Step 6: Ventilate the room and furniture
Open the room windows where suitable and leave cabinet doors or drawers open.
After ventilation, repeat the general room and near-furniture measurements.
Step 7: Repeat on another day
Repeat the same procedure under similar conditions. A consistent trend is more useful than one isolated measurement.
Suggested Test Record
LocationTest conditionHCHOTVOCTemperatureHumidityBedroom centreRoom closedRecordRecordJMS12JMS12Near wardrobeDoors closedRecordRecordJMS12JMS12Inside wardrobeCabinet closedRecordRecordJMS12JMS12Bedroom centreAfter ventilationRecordRecordJMS12JMS12Near wardrobeAfter ventilationRecordRecordJMS12JMS12
This table keeps general room readings separate from concentrated source-investigation readings.
Why Is the Reading Higher Inside the Cabinet?
A closed cabinet has limited ventilation and a much smaller internal air volume than the room.
Volatile compounds released from:
Wood panels
Adhesive
Laminate
Edge seals
Coatings
Stored products
may accumulate inside.
The higher internal reading does not automatically mean that the whole room has the same condition.
Open the cabinet doors, improve room ventilation and repeat the measurements.
Why Does the Reading Drop After Opening Cabinet Doors?
Opening the doors allows the accumulated vapours to mix with the larger volume of room air.
If windows are also opened, fresh-air exchange may further reduce the concentration.
The reading may rise again after the cabinet and room remain closed. Repeating the test helps determine whether this pattern is consistent.
Why Does the Reading Increase During the Afternoon?
Furniture and building materials may release volatile compounds differently as the room becomes warmer.
A west-facing bedroom or closed condominium unit may reach a higher temperature during the afternoon.
Other possible changes include:
Reduced ventilation
Higher humidity
Direct sunlight on furniture
Air conditioning being switched off
Longer room-closure time
The JMS12 allows temperature and humidity to be recorded with the HCHO and TVOC readings.
Can Furniture Smell Confirm Formaldehyde?
No. Odour alone cannot confirm that formaldehyde is present or determine its concentration.
A furniture smell may include several volatile substances from:
Adhesive
Coating
Packaging
Plastic
Foam
Cleaning agents
Wood products
Similarly, the absence of a strong smell does not prove that no volatile compounds are present.
The JMS11 and JMS12 provide screening information but do not chemically identify every substance.
Why Does Furniture Polish Cause a High TVOC Reading?
Furniture polish, cleaning spray and fragrance products may contain volatile ingredients.
If a cabinet is cleaned immediately before testing, the detector may respond to the cleaning product rather than only to emissions from the furniture material.
For a more meaningful comparison:
Stop using the cleaning product.
Remove the bottle or cloth from the area.
Ventilate the room.
Allow the environment to stabilise.
Repeat the test later.
Always record whether cleaning was recently performed.
Should New Cabinets Be Kept Open?
Opening cabinet doors and drawers can help trapped vapours disperse into the room, where they may then be removed through ventilation.
Practical actions may include:
Opening cabinet doors
Opening drawers
Increasing fresh-air exchange
Avoiding immediate storage of fragrance products
Keeping the room suitably ventilated
Repeating measurements over time
Ventilation requirements depend on the property and outdoor conditions. Consider security, rain and outdoor pollution before leaving windows open.
Can an Air Purifier Remove HCHO and TVOC?
Air purifiers are designed with different filtration technologies.
A standard particulate filter may be effective for particles but may not necessarily remove gaseous pollutants effectively.
When selecting equipment for gaseous pollutants, check whether it includes suitable gas-phase filtration, such as an appropriate activated-carbon or chemical filtration stage.
Filter capacity, airflow and replacement frequency are also important.
Do not assume that a lower PM2.5 reading means HCHO or TVOC has also been removed.
When Is Professional Testing Necessary?
Consider professional testing when:
Readings remain elevated after repeated ventilation
Occupants experience persistent discomfort
A certified property report is required
A dispute exists between buyer, tenant, contractor or furniture supplier
Employee exposure must be evaluated
A particular chemical must be identified
Regulatory compliance must be demonstrated
A portable semiconductor detector is intended for screening and comparison, not certified laboratory identification.
Important Sensor Precautions
Avoid exposing the JMS11 or JMS12 directly to:
Liquid
Concentrated solvent
Wet paint vapour
Open chemical containers
Aerosol spray
Excessive heat
Heavy condensation
Keep the air openings clean and unobstructed.
If the detector is exposed to perfume, alcohol or concentrated chemical vapour, move it to clean, ventilated air and allow the readings to recover before performing another test.
Buy NOYAFA JMS11 and JMS12 in Malaysia
MTM Precision supplies the NOYAFA JMS11 and JMS12 for preliminary checks around furniture, cabinets, renovated rooms, offices and vehicles.
Contact us for:
Current stock availability
JMS11 and JMS12 comparison
Updated specifications
Suitable model selection
Alternative PM2.5 or CO2 instruments
Basic operating guidance
Delivery throughout Malaysia
Collection from our Puchong showroom
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
18 Sep 2026