NOYAFA JMS11 and JMS12 for Office Indoor Air Quality Screening Malaysia
Preliminary Air Quality Screening for Offices
New office furniture, partitions, carpet, paint and cleaning products may release volatile compounds into indoor air.
The NOYAFA JMS11 and NOYAFA JMS12 provide a convenient way to conduct preliminary screening for:
Formaldehyde—or HCHO
Total volatile organic compounds—or TVOC
The JMS12 additionally displays:
Temperature
Relative humidity
These portable instruments are useful for room comparison and trend observation. They do not replace a formal occupational indoor air quality assessment or certified laboratory analysis.
Why Check Indoor Air in an Office?
Employees may spend eight hours or more inside an office each working day.
Indoor conditions may be affected by:
New desks and cabinets
Office partitions
Carpet
Paint
Adhesive
Renovation materials
Printers and copying equipment
Cleaning products
Air fresheners
Limited fresh-air exchange
Closed meeting rooms
Stored chemicals
Preliminary screening can help identify areas that may require better ventilation or further professional investigation.
Common Office Applications
The JMS11 or JMS12 may be used for initial checks in:
Newly renovated offices
Meeting rooms
Training rooms
Workstation areas
Reception areas
Printing rooms
Storage rooms
Pantry areas
New furniture sections
Rooms with a noticeable chemical smell
Each area should be evaluated separately because materials, occupancy and ventilation may differ.
JMS11 or JMS12 for Office Use?
NOYAFA JMS11
The JMS11 is suitable when the main requirement is:
Basic HCHO screening
Basic TVOC screening
Occasional office checks
Simple operation
Replaceable battery power
Lower initial cost
NOYAFA JMS12
The JMS12 is more suitable when the user also wants:
Temperature
Relative humidity
A more complete test record
Repeated monitoring
Rechargeable operation
Comparison of air-conditioned and non-air-conditioned conditions
For regular office checks, the JMS12 generally provides more useful environmental information.
Checking a Newly Renovated Office
A newly renovated workplace may contain:
New partitions
Fresh paint
Carpet adhesive
Vinyl flooring
Built-in cabinets
Workstations
Chairs
Decorative panels
Sealants
Cleaning-product residue
Do not rely on smell alone. A strong smell cannot identify a specific chemical, while the absence of smell does not prove that no volatile pollutants are present.
Use a structured room-comparison method.
Step-by-Step Office Screening Method
Step 1: Prepare a location list
Identify the areas to be checked, such as:
Reception
Open office
Meeting room
Manager’s room
Printing area
Storeroom
Newly renovated section
Older unaffected section
Using a planned sequence improves consistency.
Step 2: Record operating conditions
Before each measurement, note:
Air conditioner on or off
Doors open or closed
Windows open or closed
Number of occupants
Cleaning recently completed
New furniture present
Time of day
These details are important when comparing readings.
Step 3: Avoid interfering products
Do not test immediately after:
Spraying air freshener
Using alcohol disinfectant
Applying perfume
Cleaning tables
Polishing furniture
Using aerosol products
Allow the area to ventilate and stabilise first.
Step 4: Position the detector
Place the JMS11 or JMS12 in an open position representative of the occupied area.
Avoid:
Direct air-conditioner airflow
Open windows
Printer exhaust outlets
Sanitiser dispensers
Cleaning-product cabinets
Direct contact with new furniture
Blocking the sensor openings
Step 5: Allow the readings to stabilise
Keep the instrument in one location before recording:
HCHO
TVOC
Temperature and humidity for JMS12
Time
Room condition
Step 6: Compare locations
Repeat the same method in every selected area.
An older, unaffected office area may provide a useful internal comparison with the newly renovated section.
Suggested Office Inspection Record
AreaHCHOTVOCTemperatureHumidityOccupancyVentilationReceptionRecordRecordJMS12JMS12RecordRecordOpen officeRecordRecordJMS12JMS12RecordRecordMeeting roomRecordRecordJMS12JMS12RecordRecordNew furniture areaRecordRecordJMS12JMS12RecordRecordPrinting roomRecordRecordJMS12JMS12RecordRecordOlder office sectionRecordRecordJMS12JMS12RecordRecord
Repeat the record after ventilation or on another day if a particular area shows a consistent difference.
Why Can Meeting-Room Readings Be Different?
Meeting rooms may remain closed for long periods and then become occupied by several people.
Their conditions can change due to:
Limited ventilation
Closed doors
Higher temperature
Increased humidity
Furniture
Carpet
Cleaning products
Whiteboard cleaner
Air freshener
The JMS12 can record temperature and humidity, but it should not be treated as a dedicated carbon dioxide monitor.
If the purpose is to assess occupancy-related ventilation, use a specified NDIR CO2 meter.
TVOC Is Not Carbon Dioxide
A TVOC reading cannot be converted into carbon dioxide concentration.
For office ventilation assessment, a proper CO2 instrument should state:
CO2 measurement in ppm
Sensor type
Measurement range
Accuracy
Preferably NDIR technology
The JMS11 and JMS12 are used mainly for HCHO and TVOC screening, not occupancy-related CO2 assessment.
Why Can the Printing Area Show a Different Reading?
Printers, copying equipment, paper products, toner-related processes and cleaning materials may create different environmental conditions from general office areas.
If an increased reading is observed near printing equipment:
Compare it with the open office.
Check ventilation.
Record whether equipment was operating.
Avoid placing the detector against an exhaust outlet.
Repeat the test when the equipment is not operating.
A portable reading alone cannot identify the exact chemical source.
Why Does the Reading Increase After Office Cleaning?
Office cleaners may use:
Alcohol
Disinfectant
Floor cleaner
Glass cleaner
Furniture polish
Air freshener
These products can release volatile compounds and temporarily affect semiconductor gas sensors.
If the purpose is to assess normal occupied conditions, conduct the test after cleaning vapours have dispersed.
Record the cleaning time when comparing results.
Why Does the Reading Change When Air Conditioning Starts?
Air conditioning can change:
Temperature
Humidity
Air circulation
Mixing of indoor air
However, many systems mainly recirculate air and do not necessarily provide substantial fresh-air exchange.
A cooler room does not automatically mean that gaseous pollutants have been removed.
When taking readings, record:
Air conditioner operating condition
Fresh-air system condition
Door and window condition
Time since the system started
Checking New Office Furniture
Take separate measurements:
In the general workstation area
Near the new desk or cabinet
Inside a closed cabinet if source investigation is required
In an older furniture area
A reading inside a closed cabinet may be higher because vapours accumulate in a small enclosed space.
Do not treat an inside-cabinet reading as representative of the entire office.
Screening Before Employees Move In
A preliminary check before occupancy may be useful after:
Renovation
Repainting
Carpet installation
Furniture installation
Partition installation
Final cleaning
Compare the office:
Before ventilation
After ventilation
With air conditioning operating
At different times of day
Across different rooms
This provides a more useful picture than one measurement taken immediately after construction work ends.
What Should Be Done If One Area Is Consistently Higher?
Check for local sources
Look for new furniture, chemical storage, cleaning products, adhesive or recent repair work.
Improve ventilation
Increase suitable fresh-air exchange where practical.
Remove unnecessary chemicals
Do not store open or poorly sealed cleaning products in occupied areas.
Repeat the test
Conduct another measurement under similar conditions.
Compare another location
Use an older or unaffected office section as a reference.
Arrange professional assessment
Seek a qualified professional if elevated readings persist or employees report continuing discomfort.
Is JMS11 or JMS12 Suitable for DOSH Compliance?
The JMS11 and JMS12 should be treated as preliminary screening instruments.
They should not automatically be used as the sole instruments for:
Occupational exposure assessment
Regulatory compliance
Certified indoor air quality reporting
Legal documentation
Specific chemical identification
Formal workplace assessment should follow the applicable Malaysian requirements and use appropriate professional methods and equipment.
Important Measurement Limitations
The detectors may respond to interfering substances such as:
Perfume
Alcohol
Sanitiser
Cleaning chemicals
Air freshener
Solvent
Furniture polish
They do not replace dedicated instruments for:
PM2.5
Carbon dioxide
Carbon monoxide
Individual VOC analysis
Occupational exposure monitoring
Choose the detector according to the parameter that actually needs to be measured.
Buy NOYAFA JMS11 and JMS12 for Office Use in Malaysia
MTM Precision supplies indoor air quality and environmental testing instruments for offices, facilities teams, contractors and property managers.
Contact us for:
JMS11 and JMS12 availability
Model selection
Updated specifications
Office and renovation applications
Alternative PM2.5 or NDIR CO2 monitors
Basic operating guidance
Delivery throughout Malaysia
Collection from our Puchong showroom
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
18 Sep 2026