NOYAFA JMS11 and JMS12 for Office Indoor Air Quality Screening Malaysia

Preliminary Air Quality Screening for Offices

 

New office furniture, partitions, carpet, paint and cleaning products may release volatile compounds into indoor air.

 

The NOYAFA JMS11 and NOYAFA JMS12 provide a convenient way to conduct preliminary screening for:

 

Formaldehyde—or HCHO

 

Total volatile organic compounds—or TVOC

 

The JMS12 additionally displays:

 

Temperature

 

Relative humidity

 

These portable instruments are useful for room comparison and trend observation. They do not replace a formal occupational indoor air quality assessment or certified laboratory analysis.

 

Why Check Indoor Air in an Office?

 

Employees may spend eight hours or more inside an office each working day.

 

Indoor conditions may be affected by:

 

New desks and cabinets

 

Office partitions

 

Carpet

 

Paint

 

Adhesive

 

Renovation materials

 

Printers and copying equipment

 

Cleaning products

 

Air fresheners

 

Limited fresh-air exchange

 

Closed meeting rooms

 

Stored chemicals

 

Preliminary screening can help identify areas that may require better ventilation or further professional investigation.

 

Common Office Applications

 

The JMS11 or JMS12 may be used for initial checks in:

 

Newly renovated offices

 

Meeting rooms

 

Training rooms

 

Workstation areas

 

Reception areas

 

Printing rooms

 

Storage rooms

 

Pantry areas

 

New furniture sections

 

Rooms with a noticeable chemical smell

 

Each area should be evaluated separately because materials, occupancy and ventilation may differ.

 

JMS11 or JMS12 for Office Use?

 

NOYAFA JMS11

 

The JMS11 is suitable when the main requirement is:

 

Basic HCHO screening

 

Basic TVOC screening

 

Occasional office checks

 

Simple operation

 

Replaceable battery power

 

Lower initial cost

 

NOYAFA JMS12

 

The JMS12 is more suitable when the user also wants:

 

Temperature

 

Relative humidity

 

A more complete test record

 

Repeated monitoring

 

Rechargeable operation

 

Comparison of air-conditioned and non-air-conditioned conditions

 

For regular office checks, the JMS12 generally provides more useful environmental information.

 

Checking a Newly Renovated Office

 

A newly renovated workplace may contain:

 

New partitions

 

Fresh paint

 

Carpet adhesive

 

Vinyl flooring

 

Built-in cabinets

 

Workstations

 

Chairs

 

Decorative panels

 

Sealants

 

Cleaning-product residue

 

Do not rely on smell alone. A strong smell cannot identify a specific chemical, while the absence of smell does not prove that no volatile pollutants are present.

 

Use a structured room-comparison method.

 

Step-by-Step Office Screening Method

 

Step 1: Prepare a location list

 

Identify the areas to be checked, such as:

 

Reception

 

Open office

 

Meeting room

 

Manager’s room

 

Printing area

 

Storeroom

 

Newly renovated section

 

Older unaffected section

 

Using a planned sequence improves consistency.

 

Step 2: Record operating conditions

 

Before each measurement, note:

 

Air conditioner on or off

 

Doors open or closed

 

Windows open or closed

 

Number of occupants

 

Cleaning recently completed

 

New furniture present

 

Time of day

 

These details are important when comparing readings.

 

Step 3: Avoid interfering products

 

Do not test immediately after:

 

Spraying air freshener

 

Using alcohol disinfectant

 

Applying perfume

 

Cleaning tables

 

Polishing furniture

 

Using aerosol products

 

Allow the area to ventilate and stabilise first.

 

Step 4: Position the detector

 

Place the JMS11 or JMS12 in an open position representative of the occupied area.

 

Avoid:

 

Direct air-conditioner airflow

 

Open windows

 

Printer exhaust outlets

 

Sanitiser dispensers

 

Cleaning-product cabinets

 

Direct contact with new furniture

 

Blocking the sensor openings

 

Step 5: Allow the readings to stabilise

 

Keep the instrument in one location before recording:

 

HCHO

 

TVOC

 

Temperature and humidity for JMS12

 

Time

 

Room condition

 

Step 6: Compare locations

 

Repeat the same method in every selected area.

 

An older, unaffected office area may provide a useful internal comparison with the newly renovated section.

 

Suggested Office Inspection Record

 

AreaHCHOTVOCTemperatureHumidityOccupancyVentilationReceptionRecordRecordJMS12JMS12RecordRecordOpen officeRecordRecordJMS12JMS12RecordRecordMeeting roomRecordRecordJMS12JMS12RecordRecordNew furniture areaRecordRecordJMS12JMS12RecordRecordPrinting roomRecordRecordJMS12JMS12RecordRecordOlder office sectionRecordRecordJMS12JMS12RecordRecord

 

Repeat the record after ventilation or on another day if a particular area shows a consistent difference.

 

Why Can Meeting-Room Readings Be Different?

 

Meeting rooms may remain closed for long periods and then become occupied by several people.

 

Their conditions can change due to:

 

Limited ventilation

 

Closed doors

 

Higher temperature

 

Increased humidity

 

Furniture

 

Carpet

 

Cleaning products

 

Whiteboard cleaner

 

Air freshener

 

The JMS12 can record temperature and humidity, but it should not be treated as a dedicated carbon dioxide monitor.

 

If the purpose is to assess occupancy-related ventilation, use a specified NDIR CO2 meter.

 

TVOC Is Not Carbon Dioxide

 

A TVOC reading cannot be converted into carbon dioxide concentration.

 

For office ventilation assessment, a proper CO2 instrument should state:

 

CO2 measurement in ppm

 

Sensor type

 

Measurement range

 

Accuracy

 

Preferably NDIR technology

 

The JMS11 and JMS12 are used mainly for HCHO and TVOC screening, not occupancy-related CO2 assessment.

 

Why Can the Printing Area Show a Different Reading?

 

Printers, copying equipment, paper products, toner-related processes and cleaning materials may create different environmental conditions from general office areas.

 

If an increased reading is observed near printing equipment:

 

Compare it with the open office.

 

Check ventilation.

 

Record whether equipment was operating.

 

Avoid placing the detector against an exhaust outlet.

 

Repeat the test when the equipment is not operating.

 

A portable reading alone cannot identify the exact chemical source.

 

Why Does the Reading Increase After Office Cleaning?

 

Office cleaners may use:

 

Alcohol

 

Disinfectant

 

Floor cleaner

 

Glass cleaner

 

Furniture polish

 

Air freshener

 

These products can release volatile compounds and temporarily affect semiconductor gas sensors.

 

If the purpose is to assess normal occupied conditions, conduct the test after cleaning vapours have dispersed.

 

Record the cleaning time when comparing results.

 

Why Does the Reading Change When Air Conditioning Starts?

 

Air conditioning can change:

 

Temperature

 

Humidity

 

Air circulation

 

Mixing of indoor air

 

However, many systems mainly recirculate air and do not necessarily provide substantial fresh-air exchange.

 

A cooler room does not automatically mean that gaseous pollutants have been removed.

 

When taking readings, record:

 

Air conditioner operating condition

 

Fresh-air system condition

 

Door and window condition

 

Time since the system started

 

Checking New Office Furniture

 

Take separate measurements:

 

In the general workstation area

 

Near the new desk or cabinet

 

Inside a closed cabinet if source investigation is required

 

In an older furniture area

 

A reading inside a closed cabinet may be higher because vapours accumulate in a small enclosed space.

 

Do not treat an inside-cabinet reading as representative of the entire office.

 

Screening Before Employees Move In

 

A preliminary check before occupancy may be useful after:

 

Renovation

 

Repainting

 

Carpet installation

 

Furniture installation

 

Partition installation

 

Final cleaning

 

Compare the office:

 

Before ventilation

 

After ventilation

 

With air conditioning operating

 

At different times of day

 

Across different rooms

 

This provides a more useful picture than one measurement taken immediately after construction work ends.

 

What Should Be Done If One Area Is Consistently Higher?

 

Check for local sources

 

Look for new furniture, chemical storage, cleaning products, adhesive or recent repair work.

 

Improve ventilation

 

Increase suitable fresh-air exchange where practical.

 

Remove unnecessary chemicals

 

Do not store open or poorly sealed cleaning products in occupied areas.

 

Repeat the test

 

Conduct another measurement under similar conditions.

 

Compare another location

 

Use an older or unaffected office section as a reference.

 

Arrange professional assessment

 

Seek a qualified professional if elevated readings persist or employees report continuing discomfort.

 

Is JMS11 or JMS12 Suitable for DOSH Compliance?

 

The JMS11 and JMS12 should be treated as preliminary screening instruments.

 

They should not automatically be used as the sole instruments for:

 

Occupational exposure assessment

 

Regulatory compliance

 

Certified indoor air quality reporting

 

Legal documentation

 

Specific chemical identification

 

Formal workplace assessment should follow the applicable Malaysian requirements and use appropriate professional methods and equipment.

 

Important Measurement Limitations

 

The detectors may respond to interfering substances such as:

 

Perfume

 

Alcohol

 

Sanitiser

 

Cleaning chemicals

 

Air freshener

 

Solvent

 

Furniture polish

 

They do not replace dedicated instruments for:

 

PM2.5

 

Carbon dioxide

 

Carbon monoxide

 

Individual VOC analysis

 

Occupational exposure monitoring

 

Choose the detector according to the parameter that actually needs to be measured.

 

Buy NOYAFA JMS11 and JMS12 for Office Use in Malaysia

 

MTM Precision supplies indoor air quality and environmental testing instruments for offices, facilities teams, contractors and property managers.

 

Contact us for:

 

JMS11 and JMS12 availability

 

Model selection

 

Updated specifications

 

Office and renovation applications

 

Alternative PM2.5 or NDIR CO2 monitors

 

Basic operating guidance

 

Delivery throughout Malaysia

 

Collection from our Puchong showroom

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre:

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.


 

18 Sep 2026