10 Common Mistakes When Using NOYAFA JMS11 or JMS12 Air Quality Testers Malaysia

Avoid These Common Air Quality Testing Mistakes

 

The NOYAFA JMS11 and NOYAFA JMS12 are designed for preliminary indoor screening of:

 

Formaldehyde—or HCHO

 

Total volatile organic compounds—or TVOC

 

The JMS12 also displays:

 

Temperature

 

Relative humidity

 

Although both models are straightforward to operate, incorrect testing methods can produce confusing or inconsistent readings.

 

Here are ten common mistakes and the practical steps users can take to improve measurement consistency.

 

Mistake 1: Recording the Reading Immediately After Switching On

 

The sensor requires time to respond to the surrounding air.

 

The first number displayed after switching on the instrument may continue changing as the detector adjusts to the environment.

 

Better method

 

Place the tester in one position, keep the ventilation openings unobstructed and allow the readings to stabilise before recording them.

 

Use a consistent waiting period when comparing different locations.

 

Mistake 2: Moving the Detector Continuously

 

Carrying the detector from room to room without allowing stabilisation makes the readings difficult to interpret.

 

Each room may have different:

 

Temperature

 

Humidity

 

Ventilation

 

Furniture

 

Cleaning products

 

Airflow

 

Pollutant sources

 

Better method

 

Complete one location before moving to the next.

 

For every room:

 

Place the instrument.

 

Allow it to respond.

 

Record the result.

 

Note the room conditions.

 

Move to the next location.

 

Mistake 3: Testing Immediately After Using Hand Sanitiser

 

Alcohol-based sanitiser can cause a strong response from semiconductor gas sensors.

 

This frequently happens when the user sanitises their hands and immediately handles the detector.

 

Better method

 

Keep sanitiser away from the instrument during testing.

 

If exposure occurs:

 

Move the detector to clean, ventilated air.

 

Allow the readings to recover.

 

Do not blow into the sensor.

 

Repeat the test later.

 

Do not clean the air openings with alcohol.

 

Mistake 4: Spraying Perfume or Air Freshener Nearby

 

Perfume and air fresheners release volatile fragrance compounds. These vapours may increase the TVOC response.

 

A high reading after spraying fragrance does not automatically confirm a formaldehyde problem.

 

Better method

 

Remove fragrance products from the test area and avoid spraying anything during measurement.

 

Ventilate the room and allow it to stabilise before repeating the test.

 

Mistake 5: Placing the Detector Directly Beside a Chemical Source

 

Positioning the tester immediately beside:

 

Wet paint

 

Open adhesive

 

Solvent

 

Cleaning liquid

 

Furniture polish

 

An air freshener

 

may expose the sensor to a concentrated vapour.

 

This does not represent the normal occupied area of the room.

 

Better method

 

Take two separate measurements:

 

A general room measurement

 

A source-investigation measurement

 

Label them clearly and do not treat them as equivalent.

 

Mistake 6: Testing Only Inside a Closed Cabinet

 

Vapours can accumulate inside a small closed cabinet because of limited air exchange.

 

The inside-cabinet reading may be much higher than the reading in the bedroom or living room.

 

Better method

 

Take readings:

 

In the centre of the room

 

Near the cabinet

 

Inside the cabinet

 

After ventilation

 

Record each location separately.

 

An inside-cabinet result should not be presented as the general room concentration.

 

Mistake 7: Comparing Readings Taken Under Different Conditions

 

A room measured with all windows open cannot be compared directly with the same room after it has remained closed overnight without noting the different conditions.

 

Other variables may include:

 

Air conditioner on or off

 

Morning or afternoon

 

Hot or cool room

 

Cleaning recently completed

 

Different detector position

 

Different measurement duration

 

Better method

 

Keep the test conditions as consistent as possible and record every relevant difference.

 

The JMS12 helps by displaying temperature and humidity together with HCHO and TVOC.

 

Mistake 8: Blocking the Sensor Openings

 

The ventilation openings allow surrounding air to reach the sensor.

 

The response may become slow or inconsistent if the detector is:

 

Covered by a cloth

 

Held tightly

 

Placed in a bag

 

Pressed against a wall

 

Positioned on a soft surface

 

Kept inside a closed container

 

Better method

 

Place the unit on a stable surface with all air openings exposed.

 

Avoid holding it continuously during the test.

 

Mistake 9: Expecting Two Detectors to Show Identical Numbers

 

Two portable air quality testers may not display exactly the same value.

 

Possible reasons include:

 

Different sensor types

 

Individual sensor tolerance

 

Sensor age

 

Different response algorithms

 

Different exposure history

 

Slightly different placement

 

Air movement

 

Temperature and humidity

 

Better method

 

Use the same detector for repeated trend comparison whenever possible.

 

If comparing two instruments, place them together under identical conditions and allow both to stabilise.

 

For formal confirmation, use the appropriate professional reference method.

 

Mistake 10: Treating One Reading as a Certified Result

 

A single portable reading cannot provide a complete analysis of indoor air.

 

The JMS11 and JMS12 are useful for:

 

Preliminary screening

 

Room comparison

 

Checking before and after ventilation

 

Observing trends

 

Identifying areas for further investigation

 

They do not replace:

 

Laboratory analysis

 

Occupational exposure assessment

 

Regulatory compliance testing

 

Certified indoor air quality reports

 

Identification of individual chemical compounds

 

Better method

 

Repeat the test under controlled conditions. Arrange professional assessment when a certified or legally defensible result is required.

 

Additional Mistake: Confusing TVOC with CO2

 

TVOC and carbon dioxide are different measurements.

 

A TVOC reading cannot be converted into a reliable CO2 concentration.

 

For occupied-room ventilation assessment, use a dedicated CO2 meter that states:

 

Measurement in ppm

 

CO2 range

 

Accuracy

 

Sensor type

 

Preferably NDIR technology

 

The JMS11 and JMS12 should not be treated as dedicated CO2 instruments unless the exact product specification states otherwise.

 

Additional Mistake: Using JMS11 or JMS12 as a PM2.5 Monitor

 

HCHO and TVOC are gaseous-pollutant indicators. PM2.5 refers to fine airborne particles.

 

For haze, smoke and fine dust, choose a dedicated PM2.5 monitor with an optical particle sensor.

 

A low TVOC reading does not prove that PM2.5 is low.

 

Additional Mistake: Blowing into the Sensor

 

Some users blow directly into the detector to check whether it responds.

 

Human breath contains moisture and other compounds that can influence the sensor.

 

Better method

 

Allow the instrument to respond naturally to the room air.

 

Do not use breath, alcohol, perfume or concentrated chemical vapour as a functional test.

 

Additional Mistake: Exposing the Detector to Concentrated Chemicals

 

Deliberately placing the instrument above an open solvent, formaldehyde source or fuel container is unsafe and may overload the sensor.

 

Concentrated exposure may:

 

Saturate the sensor

 

Contaminate the air path

 

Extend recovery time

 

Damage the instrument

 

Create health and fire risks

 

Use normal room comparisons instead.

 

Recommended Testing Procedure

 

For a more consistent result:

 

1. Prepare the room

 

Avoid perfume, cleaning spray, sanitiser and air freshener.

 

2. Record the room condition

 

Note doors, windows, air conditioning, temperature and recent activities.

 

3. Position the detector

 

Use an open location away from direct airflow and concentrated sources.

 

4. Allow stabilisation

 

Do not record the first displayed number.

 

5. Record the results

 

Record HCHO, TVOC, location and time. Add temperature and humidity when using the JMS12.

 

6. Ventilate the area

 

Open suitable doors or windows where outdoor conditions permit.

 

7. Repeat the test

 

Use the same position and similar timing.

 

8. Compare the trend

 

Look for repeatable patterns instead of depending on one isolated result.

 

Suggested Measurement Record

 

Date and timeLocationHCHOTVOCTemperatureHumidityRoom conditionTest 1Bedroom centreRecordRecordJMS12JMS12ClosedTest 2Bedroom centreRecordRecordJMS12JMS12After ventilationTest 3Near wardrobeRecordRecordJMS12JMS12Cabinet closedTest 4Other roomRecordRecordJMS12JMS12Comparison

 

This approach makes the results easier to understand and explain.

 

When Should You Contact the Supplier?

 

Contact the supplier if the instrument:

 

Does not switch on

 

Cannot charge correctly

 

Displays a continuous error

 

Has damaged buttons or screen

 

Was exposed to liquid

 

Shows an abnormal value in several clean locations

 

Does not respond to any environmental change

 

Has suffered impact or excessive heat

 

Provide:

 

Model number

 

Photo or video of the display

 

Test location

 

Operating time

 

Nearby products

 

Room condition

 

Steps already taken

 

This information helps distinguish a possible product fault from an environmental response.

 

JMS11 or JMS12: Which Is Easier to Document?

 

The JMS11 is straightforward for HCHO and TVOC screening.

 

The JMS12 provides a more complete record because it also displays temperature and humidity.

 

Choose:

 

JMS11 for simple, occasional checks

 

JMS12 for repeated monitoring and environmental comparison

 

Both models should be used as screening instruments within the limitations of their sensor technology.

 

Buy NOYAFA JMS11 and JMS12 in Malaysia

 

MTM Precision supplies the NOYAFA JMS11 and JMS12 air quality testers for homes, offices, vehicles and renovated properties.

 

Contact us for:

 

Model selection

 

Stock availability

 

Updated specifications

 

Basic operating guidance

 

Troubleshooting support

 

Alternative PM2.5 or NDIR CO2 monitors

 

Delivery throughout Malaysia

 

Collection from our Puchong showroom

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre:

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.


 

18 Sep 2026