EMF Testing Near Electrical Panels, Transformers and Switchgear Malaysia
EMF Testing Near Electrical Panels, Transformers and Switchgear Malaysia
Electrical panels, transformers and switchgear are essential parts of factories, commercial buildings, data centres and industrial facilities throughout Malaysia.
Because these systems carry and distribute electrical power, electromagnetic fields may be present around the equipment during operation.
For electrical technicians, facility engineers and maintenance teams, an EMF meter such as the TENMARS TM-190T can be used to investigate how electromagnetic field readings vary around electrical installations and at normal working positions.
Why Measure EMF Around Electrical Equipment?
Electrical equipment can produce low-frequency electric and magnetic fields.
Typical equipment includes:
Main switchboards
Distribution boards
Transformers
Switchgear
Power cables
Busbars
Motor control centres
UPS systems
Electrical machinery
Field levels are not necessarily the same everywhere around the equipment.
They can vary according to:
Electrical load
Current
Equipment design
Cable arrangement
Distance
Measurement direction
Nearby electrical sources
This makes systematic measurement important.
Which Type of EMF Should You Measure?
One common mistake is treating all electromagnetic fields as the same.
For conventional electrical power equipment, the relevant investigation will often involve low-frequency magnetic fields and AC electric fields.
RF measurement is a different category and is more relevant to sources such as wireless communication equipment.
The TENMARS TM-190T is useful in mixed environments because it supports:
3-axis low-frequency magnetic field measurement
AC electric field measurement
RF electromagnetic field measurement
Its RF function covers 50 MHz to 10 GHz.
Measuring EMF Around an Electrical Panel
Do not take only one reading directly against the panel.
A better investigation compares several measurement positions.
For example:
Background area → 2 metres → 1 metre → normal operator position → near the panel
Record the result at each location.
This allows you to see how the electromagnetic field changes as the measurement point moves closer to the equipment.
Measure the Normal Working Position
This is particularly important in workplace investigations.
A technician may only stand directly beside a switchboard for a short period, while another operator may spend considerably more time at a nearby workstation.
Therefore, useful measurement points can include:
Normal operating position
Maintenance position
Nearby workstation
Walkway
Control station
Background location
This provides more context than simply searching for the highest possible reading.
EMF Measurement Around Transformers
Transformers are another common investigation point.
Measurements can be taken at several distances and positions around the installation.
For example:
Measurement PointPositionResultABackground areaRecord readingB2 m from transformerRecord readingC1 m from transformerRecord readingDNormal working positionRecord readingENear transformerRecord reading
The actual measurement plan should be adapted to the site and purpose of the investigation.
Why Transformer Readings Can Change with Load
Electrical operating conditions matter.
A transformer supplying a light load may not produce exactly the same field conditions as when the electrical load is much higher.
Therefore, when recording measurements, also note relevant operating conditions.
Useful information can include:
Date
Time
Measurement position
Distance
Field type
Reading
Equipment status
Approximate operating condition
This becomes particularly valuable when measurements are repeated later.
EMF Measurement Around Switchgear
Switchgear installations can contain multiple conductors, busbars, breakers and cable routes.
The electromagnetic environment may therefore vary across different parts of the installation.
Instead of assuming that one measurement represents the entire switchgear area, technicians can compare readings at:
Front of switchgear
Side of switchgear
Operator position
Cable entry area
Nearby walkway
Adjacent working areas
Consistent measurement positions are particularly important when building historical comparison data.
Why 3-Axis Magnetic Field Measurement Helps
Magnetic fields have direction.
With single-axis measurement, the orientation of the sensor can influence the reading.
The TENMARS TM-190T provides 3-axis magnetic field measurement, which is useful when the field direction is unknown.
This can make practical measurements around complex electrical installations easier.
Electrical Room EMF Survey
An electrical room may contain several potential electromagnetic sources at the same time.
For example:
Main switchboard
Transformers
Distribution boards
UPS systems
Power cables
Control equipment
A useful survey approach is to create a simple measurement map.
Mark several repeatable points around the room and record the readings at each position.
If future measurements are required, technicians can return to approximately the same positions for comparison.
EMF Testing in Data Centre Electrical Rooms
Data centres contain substantial electrical infrastructure.
Possible investigation areas include:
Main distribution boards
UPS rooms
Transformer areas
Power distribution equipment
Electrical cable routes
Server rooms
Network areas
Data centres can also contain RF communication sources.
This creates a mixed electromagnetic environment.
The TM-190T can be particularly practical here because technicians can investigate both low-frequency electrical fields and higher-frequency RF fields using one instrument.
EMF Measurement in Factories
Factories can contain even more varied sources.
Examples include:
Switchboards
Motors
Pumps
Compressors
Transformers
Production machinery
Welding equipment
Power cables
Wireless communication systems
When investigating factory EMF conditions, separate the different source types rather than assuming all readings come from the same equipment.
Can EMF Testing Detect an Electrical Fault?
An EMF meter should not automatically be treated as an electrical fault detector.
A changed reading may justify further investigation, but it does not by itself identify the cause of an electrical problem.
For electrical maintenance, other instruments may also be required depending on the problem, such as:
Clamp meters
Multimeters
Insulation testers
Thermal imagers
Power analysers
Earth resistance testers
EMF measurement should be considered one part of a broader investigation where appropriate.
Does a High EMF Reading Mean the Switchboard Is Dangerous?
Not automatically.
A measured value requires context before any safety conclusion can be made.
Factors can include:
Field type
Frequency
Measurement units
Distance
Exposure duration
Measurement procedure
Applicable guideline or standard
For formal occupational exposure or compliance assessments, users should identify the applicable standard and required measurement method.
Common Measurement Mistakes
Measuring Only at the Equipment Surface
A surface measurement may not represent the field at normal working positions.
Not Recording Distance
Without distance information, later comparison becomes difficult.
Comparing Different Operating Conditions
Changes in electrical load can influence measurements.
Confusing RF with Low-Frequency EMF
Electrical power equipment and wireless RF systems require different measurement considerations.
Making a Safety Conclusion from One Number
Measurement values should be interpreted using appropriate technical criteria.
Building an EMF Measurement Record
For industrial maintenance, consistency is valuable.
A simple record can include:
Equipment: Main Switchboard A
Location: Electrical Room
Measurement point: Operator position
Distance: 1 metre
Mode: Magnetic field
Reading: Recorded value
Equipment condition: Operating
Date/time: Recorded
Repeat the same process at selected locations.
Over time, this produces much more useful information than isolated readings with no measurement context.
Why TENMARS TM-190T for Industrial EMF Investigation?
The TENMARS TM-190T is useful when a technician encounters different electromagnetic sources during site work.
It combines:
3-axis magnetic field measurement
AC electric field measurement
RF electromagnetic field measurement from 50 MHz to 10 GHz
This makes it suitable for general electromagnetic-field investigation across electrical, industrial and wireless environments.
Looking for an EMF Meter for Electrical Testing in Malaysia?
MTM Precision Sdn Bhd supplies TENMARS and industrial testing instruments in Malaysia.
If you need to investigate electromagnetic fields around a:
Switchboard
Transformer
Electrical panel
Motor
UPS
Factory machine
Server room
Data centre
send us your application before selecting the instrument.
We can help determine whether you need low-frequency EMF measurement, RF measurement or a multi-field solution such as the TENMARS TM-190T.
Contact MTM Precision
MTM Precision Sdn Bhd
Showroom & Service Centre – Puchong, Selangor, Malaysia
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Serving customers across Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
Contact MTM Precision for TENMARS TM-190T quotation, industrial EMF meter selection and electrical testing enquiries in Malaysia.
19 Sep 2026