How to Check Electromagnetic Field Levels in Offices and Server Rooms Malaysia
How to Check Electromagnetic Field Levels in Offices and Server Rooms Malaysia
Modern offices and server rooms contain many electrical and wireless devices operating at the same time.
WiFi access points, network equipment, servers, UPS systems, electrical panels, power cables and communication equipment can all contribute to the electromagnetic environment.
For facility teams and technicians who need to investigate these environments, the TENMARS TM-190T provides a combination of 3-axis low-frequency magnetic field, AC electric field and RF electromagnetic field measurement from 50 MHz to 10 GHz.
What EMF Sources Can Be Found in an Office?
Possible electromagnetic field sources include:
WiFi access points
Wireless networking equipment
Electrical distribution boards
Power cables
Computer equipment
Server equipment
Communication devices
UPS systems
The important point is that these sources do not necessarily produce the same type of electromagnetic field.
This is why selecting the correct measurement mode matters.
What About Server Rooms?
Server rooms can contain a much higher concentration of electrical and communication equipment.
Possible sources include:
Server racks
Network switches
Power distribution units
UPS systems
Electrical cabling
Wireless access points
Communication equipment
Electrical panels
An EMF survey should therefore begin by identifying the equipment rather than simply walking around looking for the highest reading.
Low-Frequency EMF vs RF
A useful first step is to separate electromagnetic sources into two broad groups.
Electrical Sources
Examples include:
Electrical panels
UPS equipment
Power cables
Transformers
Low-frequency magnetic and electric-field measurements may be relevant to these sources.
Wireless and RF Sources
Examples include:
WiFi access points
Wireless communication equipment
RF transmitters
RF electromagnetic-field measurement is relevant to these sources.
The TM-190T can investigate both categories.
Step 1 – Create a Simple Measurement Map
Before measuring, identify several points around the room.
For an office, these might include:
Reception
Employee workstations
Meeting room
WiFi access point area
Electrical panel
Server room entrance
For a server room:
Entrance
Technician working position
Server rack area
UPS area
Network equipment area
Electrical distribution area
Number the measurement points so they can be repeated later.
Step 2 – Take a Background Reading
Start in an area away from the suspected source.
This provides a reference reading for comparison.
Do not assume the background value will be zero.
Other electrical and RF sources may still be present.
Step 3 – Check Normal Occupied Positions
One of the most useful measurements is at the location where people normally work.
Examples include:
Office desk
Server-room technician position
Control desk
Maintenance position
Meeting-room seating area
A measurement directly beside a piece of equipment may be useful for source investigation, but it does not necessarily represent conditions at the normal occupied position.
Step 4 – Compare Distance
Take readings at consistent distances where practical.
For example:
Background → 2 m → 1 m → normal working position → near source
Record the distance with every measurement.
This makes future comparison much easier.
Step 5 – Select the Correct Field Type
If you are checking an electrical distribution panel, use the measurement function appropriate to the electrical field being investigated.
If you are checking a WiFi access point, RF measurement is relevant.
Do not assume that one measurement mode represents every electromagnetic source in the room.
Example Office EMF Survey
A simple office record might look like this:
LocationSuspected SourceMeasurement TypeWorkstation AGeneral environmentAppropriate EMF checkMeeting RoomWiFi access pointRFElectrical RoomDistribution panelLow-frequency EMFServer RoomMixed equipmentMultiple measurementsReceptionGeneral environmentReference
Actual readings can then be added for each location.
Checking Around WiFi Access Points
WiFi equipment produces RF electromagnetic fields.
When investigating an access point, compare readings at:
Background location
Several metres away
Normal occupied position
Closer to the access point
RF readings can fluctuate because wireless transmission activity changes over time.
Repeated measurements may therefore provide more useful information than one instantaneous value.
Checking Around UPS Systems
UPS equipment is common in server rooms and data centres.
When investigating the electromagnetic environment around a UPS system, consider:
Distance
Electrical load
Cable routing
Normal technician position
Nearby electrical equipment
If measurements will be repeated later, use consistent locations.
Checking Around Server Racks
A server rack may contain multiple pieces of electronic and networking equipment.
Do not automatically assume that any measured electromagnetic field originates from one server.
Nearby equipment, power distribution and communication systems may also contribute.
Take measurements at several positions around the rack and document the measurement type.
Why 3-Axis Measurement Helps
The TM-190T provides 3-axis low-frequency magnetic field measurement.
This is useful around electrical infrastructure because the magnetic-field direction may not be obvious.
Instead of depending only on one sensor orientation, the instrument evaluates magnetic-field components across three spatial directions.
RF Measurement Up to 10GHz
For higher-frequency RF investigation, the TM-190T covers:
50 MHz to 10 GHz
This makes it relevant for broad RF field investigation around many wireless and communication sources operating within this frequency range.
However, it is important to remember:
The TM-190T is not a spectrum analyser.
It measures RF electromagnetic field strength but does not automatically identify individual frequencies, WiFi channels or transmitters.
Server Room vs Data Centre
A server room may contain only a few racks and supporting equipment.
A large data centre can contain extensive:
Server infrastructure
Network equipment
Power distribution
UPS systems
Cooling systems
Communication infrastructure
As the facility becomes more complex, a structured measurement plan becomes increasingly important.
Building an EMF Measurement Record
For repeat inspections, record:
Location: Server Room A
Measurement Point: Rack 03 technician position
Distance: Recorded
Measurement Mode: RF / magnetic / electric field
Reading: Recorded value
Equipment Condition: Normal operation
Date & Time: Recorded
This provides much better information than an isolated EMF number.
Can an EMF Meter Find a Faulty Server?
Not directly.
An EMF meter should not be treated as a server diagnostic instrument.
If a server, UPS or electrical system has a fault, other diagnostic equipment may be needed.
Depending on the problem, technicians may use:
Thermal imagers
Clamp meters
Multimeters
Power analysers
Environmental monitors
Network testers
EMF measurement is one part of a broader facility investigation.
Does a High Reading Mean the Office Is Unsafe?
Not automatically.
A measurement result needs technical context before a safety conclusion is made.
Relevant factors may include:
Field type
Frequency
Measurement units
Measurement position
Exposure duration
Applicable guidelines
Measurement procedure
For formal occupational or regulatory assessment, the applicable exposure standard and required measurement methodology should be identified.
Why TENMARS TM-190T for Offices and Server Rooms?
The advantage of the TENMARS TM-190T is its multi-field capability.
One facility may contain:
Electrical equipment → low-frequency fields
and
Wireless equipment → RF fields
The TM-190T allows technicians to investigate both categories using one portable instrument.
This can be particularly useful for:
Facility management
Server-room inspection
Data-centre maintenance
Electrical maintenance
Workplace environmental investigation
Looking for an EMF Meter for Server Rooms in Malaysia?
MTM Precision Sdn Bhd supplies TENMARS and industrial testing instruments in Malaysia.
If you need to investigate electromagnetic fields in an office, server room, electrical room or data centre, tell us what equipment is present and what you need to measure.
We can help determine whether you require low-frequency EMF measurement, RF measurement or a multi-field solution such as the TENMARS TM-190T.
Contact MTM Precision
MTM Precision Sdn Bhd
Showroom & Service Centre – Puchong, Selangor, Malaysia
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Serving customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
Contact MTM Precision for TENMARS TM-190T quotation, server room EMF testing and electromagnetic field meter enquiries in Malaysia.
20 Sep 2026