How to Check Electromagnetic Field Levels in Offices and Server Rooms Malaysia

How to Check Electromagnetic Field Levels in Offices and Server Rooms Malaysia

 

Modern offices and server rooms contain many electrical and wireless devices operating at the same time.

 

WiFi access points, network equipment, servers, UPS systems, electrical panels, power cables and communication equipment can all contribute to the electromagnetic environment.

 

For facility teams and technicians who need to investigate these environments, the TENMARS TM-190T provides a combination of 3-axis low-frequency magnetic field, AC electric field and RF electromagnetic field measurement from 50 MHz to 10 GHz.

 

What EMF Sources Can Be Found in an Office?

 

Possible electromagnetic field sources include:

 

WiFi access points

 

Wireless networking equipment

 

Electrical distribution boards

 

Power cables

 

Computer equipment

 

Server equipment

 

Communication devices

 

UPS systems

 

The important point is that these sources do not necessarily produce the same type of electromagnetic field.

 

This is why selecting the correct measurement mode matters.

 

What About Server Rooms?

 

Server rooms can contain a much higher concentration of electrical and communication equipment.

 

Possible sources include:

 

Server racks

 

Network switches

 

Power distribution units

 

UPS systems

 

Electrical cabling

 

Wireless access points

 

Communication equipment

 

Electrical panels

 

An EMF survey should therefore begin by identifying the equipment rather than simply walking around looking for the highest reading.

 

Low-Frequency EMF vs RF

 

A useful first step is to separate electromagnetic sources into two broad groups.

 

Electrical Sources

 

Examples include:

 

Electrical panels

 

UPS equipment

 

Power cables

 

Transformers

 

Low-frequency magnetic and electric-field measurements may be relevant to these sources.

 

Wireless and RF Sources

 

Examples include:

 

WiFi access points

 

Wireless communication equipment

 

RF transmitters

 

RF electromagnetic-field measurement is relevant to these sources.

 

The TM-190T can investigate both categories.

 

Step 1 – Create a Simple Measurement Map

 

Before measuring, identify several points around the room.

 

For an office, these might include:

 

Reception

 

Employee workstations

 

Meeting room

 

WiFi access point area

 

Electrical panel

 

Server room entrance

 

For a server room:

 

Entrance

 

Technician working position

 

Server rack area

 

UPS area

 

Network equipment area

 

Electrical distribution area

 

Number the measurement points so they can be repeated later.

 

Step 2 – Take a Background Reading

 

Start in an area away from the suspected source.

 

This provides a reference reading for comparison.

 

Do not assume the background value will be zero.

 

Other electrical and RF sources may still be present.

 

Step 3 – Check Normal Occupied Positions

 

One of the most useful measurements is at the location where people normally work.

 

Examples include:

 

Office desk

 

Server-room technician position

 

Control desk

 

Maintenance position

 

Meeting-room seating area

 

A measurement directly beside a piece of equipment may be useful for source investigation, but it does not necessarily represent conditions at the normal occupied position.

 

Step 4 – Compare Distance

 

Take readings at consistent distances where practical.

 

For example:

 

Background → 2 m → 1 m → normal working position → near source

 

Record the distance with every measurement.

 

This makes future comparison much easier.

 

Step 5 – Select the Correct Field Type

 

If you are checking an electrical distribution panel, use the measurement function appropriate to the electrical field being investigated.

 

If you are checking a WiFi access point, RF measurement is relevant.

 

Do not assume that one measurement mode represents every electromagnetic source in the room.

 

Example Office EMF Survey

 

A simple office record might look like this:

 

LocationSuspected SourceMeasurement TypeWorkstation AGeneral environmentAppropriate EMF checkMeeting RoomWiFi access pointRFElectrical RoomDistribution panelLow-frequency EMFServer RoomMixed equipmentMultiple measurementsReceptionGeneral environmentReference

 

Actual readings can then be added for each location.

 

Checking Around WiFi Access Points

 

WiFi equipment produces RF electromagnetic fields.

 

When investigating an access point, compare readings at:

 

Background location

 

Several metres away

 

Normal occupied position

 

Closer to the access point

 

RF readings can fluctuate because wireless transmission activity changes over time.

 

Repeated measurements may therefore provide more useful information than one instantaneous value.

 

Checking Around UPS Systems

 

UPS equipment is common in server rooms and data centres.

 

When investigating the electromagnetic environment around a UPS system, consider:

 

Distance

 

Electrical load

 

Cable routing

 

Normal technician position

 

Nearby electrical equipment

 

If measurements will be repeated later, use consistent locations.

 

Checking Around Server Racks

 

A server rack may contain multiple pieces of electronic and networking equipment.

 

Do not automatically assume that any measured electromagnetic field originates from one server.

 

Nearby equipment, power distribution and communication systems may also contribute.

 

Take measurements at several positions around the rack and document the measurement type.

 

Why 3-Axis Measurement Helps

 

The TM-190T provides 3-axis low-frequency magnetic field measurement.

 

This is useful around electrical infrastructure because the magnetic-field direction may not be obvious.

 

Instead of depending only on one sensor orientation, the instrument evaluates magnetic-field components across three spatial directions.

 

RF Measurement Up to 10GHz

 

For higher-frequency RF investigation, the TM-190T covers:

 

50 MHz to 10 GHz

 

This makes it relevant for broad RF field investigation around many wireless and communication sources operating within this frequency range.

 

However, it is important to remember:

 

The TM-190T is not a spectrum analyser.

 

It measures RF electromagnetic field strength but does not automatically identify individual frequencies, WiFi channels or transmitters.

 

Server Room vs Data Centre

 

A server room may contain only a few racks and supporting equipment.

 

A large data centre can contain extensive:

 

Server infrastructure

 

Network equipment

 

Power distribution

 

UPS systems

 

Cooling systems

 

Communication infrastructure

 

As the facility becomes more complex, a structured measurement plan becomes increasingly important.

 

Building an EMF Measurement Record

 

For repeat inspections, record:

 

Location: Server Room A

Measurement Point: Rack 03 technician position

Distance: Recorded

Measurement Mode: RF / magnetic / electric field

Reading: Recorded value

Equipment Condition: Normal operation

Date & Time: Recorded

 

This provides much better information than an isolated EMF number.

 

Can an EMF Meter Find a Faulty Server?

 

Not directly.

 

An EMF meter should not be treated as a server diagnostic instrument.

 

If a server, UPS or electrical system has a fault, other diagnostic equipment may be needed.

 

Depending on the problem, technicians may use:

 

Thermal imagers

 

Clamp meters

 

Multimeters

 

Power analysers

 

Environmental monitors

 

Network testers

 

EMF measurement is one part of a broader facility investigation.

 

Does a High Reading Mean the Office Is Unsafe?

 

Not automatically.

 

A measurement result needs technical context before a safety conclusion is made.

 

Relevant factors may include:

 

Field type

 

Frequency

 

Measurement units

 

Measurement position

 

Exposure duration

 

Applicable guidelines

 

Measurement procedure

 

For formal occupational or regulatory assessment, the applicable exposure standard and required measurement methodology should be identified.

 

Why TENMARS TM-190T for Offices and Server Rooms?

 

The advantage of the TENMARS TM-190T is its multi-field capability.

 

One facility may contain:

 

Electrical equipment → low-frequency fields

 

and

 

Wireless equipment → RF fields

 

The TM-190T allows technicians to investigate both categories using one portable instrument.

 

This can be particularly useful for:

 

Facility management

 

Server-room inspection

 

Data-centre maintenance

 

Electrical maintenance

 

Workplace environmental investigation

 

Looking for an EMF Meter for Server Rooms in Malaysia?

 

MTM Precision Sdn Bhd supplies TENMARS and industrial testing instruments in Malaysia.

 

If you need to investigate electromagnetic fields in an office, server room, electrical room or data centre, tell us what equipment is present and what you need to measure.

 

We can help determine whether you require low-frequency EMF measurement, RF measurement or a multi-field solution such as the TENMARS TM-190T.

 

Contact MTM Precision

 

MTM Precision Sdn Bhd

Showroom & Service Centre – Puchong, Selangor, Malaysia

 

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

Serving customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.

 

Contact MTM Precision for TENMARS TM-190T quotation, server room EMF testing and electromagnetic field meter enquiries in Malaysia.


 

20 Sep 2026