How to Measure AC Electric Field Strength with TENMARS TM-190T Malaysia

How to Measure AC Electric Field Strength with TENMARS TM-190T Malaysia

 

When discussing electromagnetic fields, many users immediately think about magnetic fields or RF radiation from WiFi equipment.

 

However, AC electric fields are another important measurement category around energised electrical systems.

 

The TENMARS TM-190T combines AC electric field measurement with 3-axis low-frequency magnetic field and RF electromagnetic field measurement, allowing technicians to investigate several types of electromagnetic environments using one portable instrument.

 

What Is an AC Electric Field?

 

An electric field can exist around an energised conductor or electrical system because of electrical potential.

 

This is different from a magnetic field, which is strongly associated with current flow.

 

In practical electrical environments, both electric and magnetic fields may be present.

 

This is why an EMF meter capable of measuring more than one field type can be useful.

 

Electric Field vs Magnetic Field

 

These terms are often grouped together as “EMF,” but they are not identical.

 

A simple practical distinction is:

 

Electric field

Associated with electrical voltage and energised systems.

 

Magnetic field

Associated with electrical current flow.

 

The exact field conditions around equipment depend on the electrical system, equipment construction, shielding, load and measurement location.

 

Where Can AC Electric Fields Be Present?

 

Possible investigation areas include:

 

Electrical panels

 

Switchboards

 

Power cables

 

Electrical rooms

 

Industrial machinery

 

Electrical appliances

 

Power distribution systems

 

Energised equipment

 

The objective of measurement should be established before testing begins.

 

Why Use TENMARS TM-190T?

 

The TM-190T is useful because it is not limited to one type of electromagnetic field.

 

It supports:

 

AC electric field measurement

 

3-axis low-frequency magnetic field measurement

 

RF electromagnetic field measurement from 50 MHz to 10 GHz

 

This can be valuable for technicians who work across factories, commercial buildings, server rooms and data centres.

 

Step 1 – Identify the Electrical Source

 

Before measuring, identify the equipment you want to investigate.

 

For example:

 

Main switchboard

 

Distribution panel

 

Transformer area

 

Power cable

 

Electrical machinery

 

UPS system

 

Do not begin by randomly searching for the highest reading.

 

Knowing the suspected source makes the measurement much easier to interpret.

 

Step 2 – Establish a Background Measurement

 

Start at a location away from the suspected electrical source.

 

Record the reading.

 

This provides a reference that can be compared with measurements taken closer to the equipment.

 

A background reading does not necessarily have to be zero because other electrical sources may be present.

 

Step 3 – Measure at Several Distances

 

Distance is important.

 

A practical measurement sequence may be:

 

Background → 2 m → 1 m → normal operator position → closer to equipment

 

Record the distance for every measurement.

 

This allows you to understand how the electric-field reading changes according to position.

 

Step 4 – Measure Normal Working Positions

 

For workplace investigations, do not focus only on the equipment surface.

 

Also measure where people normally:

 

Stand

 

Operate equipment

 

Perform maintenance

 

Work

 

Walk past the installation

 

These positions may provide more useful information about the normal workplace environment.

 

Step 5 – Record the Conditions

 

A measurement without context is difficult to reproduce.

 

Record information such as:

 

Equipment: Distribution Panel A

Location: Electrical Room

Measurement Type: AC Electric Field

Distance: 1 metre

Position: Operator position

Reading: Recorded value

Equipment Status: Energised

Date & Time: Recorded

 

If measurements are repeated later, use the same positions where practical.

 

Why Position Matters

 

Electric-field readings can be influenced by the surrounding environment.

 

Factors may include:

 

Distance

 

Equipment enclosure

 

Nearby conductive objects

 

Building structure

 

Other electrical equipment

 

Measurement position

 

Therefore, one reading should not automatically be assumed to represent the entire room.

 

AC Electric Field Measurement Around Switchboards

 

A switchboard survey could include:

 

Background area

 

Front of switchboard

 

Normal operator position

 

Side of switchboard

 

Nearby workstation

 

Adjacent walkway

 

If one location produces a different reading, additional measurements can be taken to understand the spatial variation.

 

AC Electric Field Measurement Around Power Cables

 

Power cables are another potential investigation point.

 

Record both distance and cable location when making comparisons.

 

If several cables are grouped together, remember that the measured electromagnetic environment may be influenced by multiple conductors rather than one cable alone.

 

What About Transformers?

 

Transformers can produce electromagnetic fields during operation.

 

For transformer investigations, both magnetic-field and electric-field measurements may be relevant depending on the objective.

 

This is where a multi-field instrument such as the TM-190T can be convenient.

 

The technician can investigate different field categories without assuming that every reading represents the same phenomenon.

 

Electric Field Testing in Factories

 

Factories contain many electrical systems, including:

 

Motors

 

Control panels

 

Production machinery

 

Switchboards

 

Transformers

 

Power cables

 

Generators

 

HVAC equipment

 

Before measuring, identify the suspected source and select the appropriate TM-190T measurement function.

 

For electrical equipment, low-frequency field measurements may be relevant.

 

For wireless communication equipment, use the appropriate RF measurement function.

 

Electric Field Testing in Data Centres

 

Data centres contain substantial electrical infrastructure.

 

Potential measurement areas include:

 

Main electrical rooms

 

UPS systems

 

Power distribution equipment

 

Server halls

 

Cable routes

 

Technician working positions

 

Because data centres also contain networking and communication equipment, different electromagnetic field types may coexist in the same facility.

 

The TM-190T's multi-field capability is particularly useful in this situation.

 

Why Electric Field and RF Should Not Be Confused

 

A common mistake is to see a high reading in one EMF mode and assume it represents all electromagnetic fields.

 

It does not.

 

The AC electric-field function and RF electromagnetic-field function address different measurement categories.

 

RF measurement is relevant to higher-frequency sources such as wireless communication equipment.

 

The TM-190T RF function covers 50 MHz to 10 GHz.

 

Correct mode selection is essential.

 

Does an Electric Field Reading Show Electrical Voltage?

 

No.

 

An electric-field meter should not be treated as a voltmeter.

 

If you need to measure the actual voltage of an electrical circuit, use an appropriate electrical measurement instrument.

 

Depending on the task, this may include:

 

Multimeter

 

Voltage tester

 

Clamp meter

 

Power analyser

 

The TM-190T measures electromagnetic-field parameters rather than replacing conventional electrical test instruments.

 

Can It Detect an Electrical Fault?

 

An unusual reading may justify further investigation, but an EMF meter does not automatically diagnose the cause of an electrical fault.

 

For maintenance troubleshooting, other instruments may be required depending on the problem.

 

These could include:

 

Thermal cameras

 

Multimeters

 

Clamp meters

 

Insulation resistance testers

 

Power analysers

 

Instrument selection should always follow the measurement objective.

 

Does a Higher Reading Mean the Equipment Is Unsafe?

 

Not automatically.

 

A measurement result requires technical context.

 

Interpretation may depend on:

 

Field type

 

Frequency

 

Measurement unit

 

Distance

 

Exposure duration

 

Measurement procedure

 

Applicable exposure guideline or standard

 

For formal occupational exposure or regulatory assessments, the applicable requirements should be identified before measurements begin.

 

AC Electric Field vs RF vs Magnetic Field – Which One Do You Need?

 

A useful starting point is:

 

Electrical panel / transformer / power equipment

→ Consider low-frequency electric and magnetic field investigation.

 

WiFi / wireless communication equipment

→ Consider RF electromagnetic field measurement.

 

Mixed industrial or data-centre environment

→ A multi-field meter may be useful.

 

This is one of the main advantages of the TENMARS TM-190T.

 

Looking for an Electric Field and EMF Meter in Malaysia?

 

MTM Precision Sdn Bhd supplies TENMARS testing and measurement instruments in Malaysia.

 

If you need to measure around an electrical panel, transformer, power cable, factory machine, UPS, server room or wireless system, tell us your application.

 

We can help determine whether you need AC electric field, magnetic field, RF measurement or a combination of these functions.

 

Contact MTM Precision

 

MTM Precision Sdn Bhd

Showroom & Service Centre – Puchong, Selangor, Malaysia

 

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

Serving customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.

 

Contact MTM Precision for TENMARS TM-190T quotation, AC electric field meter enquiries and EMF measurement solutions in Malaysia.


 

20 Sep 2026