How to Measure EMF Around Electrical Panels and Equipment with TENMARS TM-290 Malaysia

How to Measure EMF Around Electrical Panels and Equipment with TENMARS TM-290 Malaysia

 

Electrical panels, distribution systems, motors and other powered equipment can produce low-frequency electromagnetic fields.

 

For maintenance teams, technicians and facility personnel, an EMF meter can be used to investigate how field readings vary around electrical equipment and at different distances.

 

The TENMARS TM-290 Multi-Field EMF Meter combines low-frequency magnetic field, electric field and RF measurement in one handheld instrument.

 

For electrical panels and mains-powered equipment, its 50/60 Hz magnetic and electric field measurement functions are particularly relevant.

 

What Should You Measure Around an Electrical Panel?

 

When checking an electrical panel, it is important to understand that “EMF” is not a single measurement.

 

The TENMARS TM-290 can measure:

 

Magnetic Field

50/60 Hz

 

Electric Field

50/60 Hz

 

RF Field

50 MHz–10 GHz

 

For a conventional electrical distribution panel, the first measurements to consider are normally the low-frequency magnetic and electric fields.

 

RF measurement serves a different purpose and should not be confused with 50/60 Hz measurements.

 

TENMARS TM-290 Magnetic Field Range

 

The TM-290 provides three low-frequency magnetic-field ranges:

 

20 mG

200 mG

2000 mG

 

The readings can also be displayed in microtesla:

 

2 µT

20 µT

200 µT

 

The instrument uses X, Y and Z three-axis measurement.

 

This is useful during field inspection because magnetic fields have direction. The TM-290 can measure the individual axes and provide an aggregated reading.

 

Step 1: Identify the Equipment

 

Before taking measurements, identify what equipment is being investigated.

 

Examples include:

 

Main electrical panel

 

Distribution board

 

Transformer

 

Motor

 

Pump

 

Compressor

 

Generator

 

UPS

 

Electrical cabinet

 

Production machine

 

Record the equipment location and its operating condition.

 

This is important because measurements taken when equipment is lightly loaded may differ from measurements taken under another operating condition.

 

Step 2: Establish a Reference Position

 

Avoid relying on only one measurement point.

 

Start from a practical reference location and record the reading.

 

Then take additional measurements at different positions around the equipment.

 

For example, measurements may be compared:

 

Directly in front of the equipment

 

To the left

 

To the right

 

At the rear, where safe and accessible

 

At increasing distances from the equipment

 

The objective is to understand how the field varies spatially.

 

Step 3: Measure the Magnetic Field

 

Select the appropriate magnetic-field measurement mode on the TM-290.

 

Observe the displayed reading and allow it to stabilise before recording the result.

 

Because the TM-290 provides three-axis measurement, users can investigate the field without relying on only one directional axis.

 

Record both the measurement value and the location.

 

For example:

 

Point A: Front of electrical panel

Point B: 0.5 m from panel

Point C: 1 m from panel

Point D: Normal operator position

 

This provides much more useful information than simply recording “EMF = X” without describing where the measurement was taken.

 

Step 4: Check the Electric Field

 

The TM-290 can also measure 50/60 Hz electric fields from 50 V/m to 2000 V/m.

 

Electric-field measurements can be taken around energized equipment and electrical installations where appropriate.

 

Again, record the measurement position.

 

Do not mix electric-field readings with magnetic-field readings.

 

They are different parameters and use different units:

 

Magnetic Field: mG or µT

Electric Field: V/m

 

Step 5: Compare Readings at Different Distances

 

One useful approach is to take measurements progressively farther from the source.

 

For example:

 

Near equipment → intermediate position → normal working position

 

This helps show how readings change across the area.

 

When comparing results over time, try to maintain similar:

 

Measurement locations

 

Equipment operating conditions

 

Meter settings

 

Measurement procedures

 

Consistency makes repeated measurements more meaningful.

 

Step 6: Record the Operating Condition

 

Do not record only the EMF value.

 

Also note what the equipment was doing during the measurement.

 

For example:

 

Motor running or stopped?

Pump operating or idle?

Electrical load high or low?

UPS under load?

Production machine operating?

 

This information can help explain why measurements differ between inspections.

 

Example: Factory Motor

 

Suppose a maintenance team wants to investigate the electromagnetic field around a large motor.

 

A simple measurement procedure could include:

 

Record the magnetic-field reading near the motor.

 

Measure at a consistent distance from the motor.

 

Take another reading at the normal operator or maintenance position.

 

Record whether the motor is operating.

 

Repeat the same measurement points during future inspections if comparison is required.

 

The TM-290's three-axis magnetic-field capability can simplify this type of field investigation.

 

Example: Electrical Distribution Room

 

An electrical room may contain several possible field sources, including:

 

Main switchboards

 

Distribution panels

 

Transformers

 

UPS systems

 

Large power cables

 

Electrical control equipment

 

Instead of taking a single measurement in the middle of the room, technicians can map several measurement points.

 

This helps identify where higher or lower readings occur within the area.

 

What About RF Measurement?

 

The TM-290 also measures RF fields from 50 MHz to 10 GHz.

 

However, this should be treated separately from its 50/60 Hz electrical measurements.

 

For example, if an electrical room also contains wireless communication equipment, the RF function may be used to investigate compatible RF sources.

 

The important point is to select the measurement mode according to the source being investigated.

 

Avoid These Common EMF Measurement Mistakes

 

Measuring Only One Point

 

One reading does not show how the field varies throughout an area.

 

Take measurements at several relevant locations.

 

Ignoring Distance

 

Always record approximately where the measurement was taken.

 

A reading close to equipment cannot automatically be compared with one taken farther away.

 

Mixing Different Units

 

Do not directly compare:

 

µT with V/m

 

or

 

mG with mW/m²

 

They represent different measurement quantities.

 

Ignoring Equipment Condition

 

If the equipment operating condition changes, the measurement conditions may also change.

 

Record relevant operating information.

 

Assuming Every EMF Source Is RF

 

Electrical power systems and wireless transmitters operate in very different frequency ranges.

 

Use the correct TM-290 measurement function for the source being investigated.

 

EMF Measurement for Preventive Investigation

 

EMF measurement should not automatically be interpreted as a diagnosis of equipment condition.

 

Instead, it can be used as one part of a broader investigation or site survey.

 

For industrial maintenance, other measurements may also be required depending on the problem, such as:

 

Vibration

 

Temperature

 

Thermal imaging

 

Electrical testing

 

Sound level

 

Power quality

 

The correct instrument depends on what the maintenance team is trying to determine.

 

TENMARS TM-290 for Electrical and Industrial Applications Malaysia

 

The TENMARS TM-290 provides a practical combination for users who need to investigate different electromagnetic fields with one portable meter.

 

Key capabilities include:

 

50/60 Hz three-axis magnetic-field measurement

50/60 Hz electric-field measurement

50 MHz–10 GHz RF measurement

 

For electrical panels, motors, electrical rooms and industrial equipment, its low-frequency magnetic and electric field functions provide useful measurement capabilities for general field investigation.

 

For TENMARS TM-290 quotation, availability or technical enquiries in Malaysia, contact:

 

MTM Precision Sdn Bhd

Puchong Showroom & Service Centre

 

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

Serving customers throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.


 

20 Sep 2026